Architectural & Engineering Specifications
July 2005
DESCRIPTION
LIGHT FIXTURE:
• Corrosion resistant finish
Satin nickel finish (Model 742SNNT)
Painted white finish (Model 742WHNT)
Oil-rubbed bronze finish (Model 742RBNT)
• Frosted melon glass shade
• Close mount design
• Uses two 60 Watt maximum, type A, medium base bulbs. Bulbs
not included.
Decorative
Light / Fans
MODELS 742SNNT
742WHNT
• Vent openings in fixture base for exhaust fan
Light fixture assembly is plug-in and removable
•
742RBNT
BLOWER:
• Plug-in permanently lubricated motor
• Polymeric blower wheel
HOUSING:
• Rugged, 26-gage galvanized steel construction
• Sturdykey-holedmountingbracketsforquick,accurateinstallation
• Tapered, polymeric duct fitting with built-in backdraft damper for
easy, positive duct connection and no metallic clatter
NOTE: For installation in ceilings up to 12/12 pitch.
U.L. Listed for use in insulated ceilings (Type I.C.)
Use supply wiring rated for at least 90° C
SPECIFICATIONS
VOLTS AMPS
120 1.6
CFM
SONES
DUCT
ARCHITECT’S SPECIFICATION
• Decorative Light / Fan shall be NuTone Model 742SNNT
(742WHNT), (742RBNT) as manufactured by NuTone according
to specifications listed:
70
2.0
4" Round
• Unit shall have galvanized steel housing with dual integral
mounting brackets. It shall be ducted to a roof or wall cap.
• Blower assembly shall be removable and have a permanently
lubricated motor.
• Light fixture assembly shall be plug-in, removable and include a
frosted melon glass shade and a corrosion-resistant base with
satinnickel(Model 742SNNT),orpaintedwhite(Model742WHNT)
finish, or oil-rubbed bronze finish (Model 742RBNT).
• Lamps shall be two 60 Watt maximum, type A, medium base,
incandescent.
HVI-2100CERTIFIED
RATINGS complywithnew
testing technologies and
procedures prescribed by
the Home Ventilating
Institute, for off-the-shelf
products, as they are
available to consumers.
Product performance is rated at 0.1 in. static
pressure, based on tests conducted in AMCA’s
state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory
measurements.
• Air delivery to be no less than 70 cfm and sound level no greater
than 2.0 sones. Air and sound ratings shall be certified by HVI.
• Unit shall be U.L. Listed for use in insulated ceilings (Type I.C.)
INSTALLATION
Complete installation instructions are
included with each Decorative Light / Fan.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-888-543-8687)
REFERENCE
QTY.
REMARKS
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
50G
99043343B
|
National Instruments Car Stereo System 320571 01 User Manual
NEC Projector VT695 700 User Manual
Netopia Network Router 4522 T1 User Manual
Niles Audio Car Amplifier SI 275 User Manual
Omega Vehicle Security Thermometer OS642F User Manual
Optimus Stereo Receiver STA 3500 User Manual
Panasonic Car Video System DVDXV10 User Manual
Panasonic Electric Shaver EW1000 User Manual
ParaBody Home Gym PBF501 User Manual
Parasound Stereo Amplifier Zpre2 User Manual