PREPARE MOUNTING SURFACE
NOTE: Minimum recom-
mendation for mounting
hardware is 1/4-20 X 5/8 Hex
Head Bolt Stainless Steel,
1/4" Split Lock Washer Stain-
less Steel, and 1/4" Flat
Washer Stainless Steel with
1" Outer Diameter.
1. Determine the mounting location. Make sure the mounting surface can support four
times the combined weight of the scanner and the camera and lens or enclosure,
camera, and lens. Refer to the manuals for your enclosure, camera, and lens for the
weights of those units.
2. If mounting directly to a flat surface, use Figure 1 as a template and mark the bolt and
cable/wire feedthrough positions onto the installation surface. Prepare the mounting
surface and pull cable/wiring for the scanner.
BOLT
HOLE
SCANNER
BOLT
BOLT
HOLE
FEED THRU
HOLE
HOLE
BOLT
HOLE
00814
Figure 1. PS20 Surface Mount Template
Pelco Manual C361M-A (8/02)
3
WIRING
Make electrical connections as required for scanner
operation. If required use the wire nuts (provided).
Cable distances should not exceed the distances
specified in Table A.
Refer to the following wiring diagrams (Figure 3)
and select the correct diagram for your installation.
GLAND AND WIRING
ATTACHMENT
Figure 2. Bottom View, Wire
Attachment
120V MODEL
24V MODEL
230V MODEL
WITH CONTROLLER
WITH CONTROLLER
WITH CONTROLLER
BLU
BRN
ORG
RED
WHT
GRN/YEL
BLK
BLU
BRN
ORG
RED
WHT
GRN/YEL
BLK
WHT
BLK
ORG
RED
BLU
GRN/YEL
BRN
COMMON
LEFT
RIGHT
COMMON
LEFT
RIGHT
COMMON
LEFT
RIGHT
CABLE
FROM
SCANNER
CABLE
FROM
SCANNER
CABLE
FROM
SCANNER
AUTO
AUTO
AUTO
120 AC LO
GROUND
120 AC HI
24 AC LO
GROUND
24 AC HI
230 AC LO
GROUND
230 AC HI
WITHOUT CONTROLLER
WITHOUT CONTROLLER
WITHOUT CONTROLLER
WHT
GRN/YEL
BLK
RED
BLU
BRN
ORG
WHT
GRN/YEL
BLK
RED
BLU
BRN
ORG
BLU
GRN/YEL
BRN
RED
WHT
ORG
BLK
120 AC LO
GROUND
120 AC HI
AUTO
120 AC LO
NOT USED
NOT USED
24 AC LO
GROUND
24 AC HI
AUTO
120 AC LO
NOT USED
NOT USED
230 AC LO
GROUND
230 AC HI
AUTO
120 AC LO
NOT USED
NOT USED
CABLE
FROM
SCANNER
CABLE
FROM
SCANNER
CABLE
FROM
SCANNER
RANDOM MODE
RANDOM MODE
RANDOM MODE
WHT
GRN/YEL
BLK
RED
ORG
WHT
GRN/YEL
BLK
RED
ORG
BLU
GRN/YEL
BRN
RED
BLK
120 AC LO
GROUND
120 AC HI
24 AC LO
GROUND
24 AC HI
230 AC LO
GROUND
230 AC HI
CABLE
FROM
SCANNER
CABLE
FROM
SCANNER
CABLE
FROM
SCANNER
BRN
BRN
ORG
BLU
BLU
WHT
00815
Figure 3. Wiring Diagrams - 120V, 24V and 230V Models
Table A. Maximum Operating Distances
Model
20 AWG
(0.5 mm2)
18 AWG
(1.0 mm2)
16 AWG
(1.5mm2)
PS20
2,300 ft
(701 m)
3,700 ft
(1,127 m)
5,900 ft
(1,798 m)
PS20-24
PS20/23
5,600 ft
(1,706 m)
9,000 ft
(2,743 m)
14,300 ft
(4,368 m)
1,400 ft
(426 m)
2,300 ft
(701 m)
3,600 ft
(1,097 m)
4
Pelco Manual C361M-A (8/02)
MOUNTING
Attach the scanner to a flat surface or compatible wall/ceiling/pedestal mount using four
bolts (not provided).
CAMERA/ENCLOSURE MOUNTING
1. Center (balance) the camera and lens, or enclosure, camera, and lens load on the tilt
table. Adjust the positioning as needed to align the mounting holes.
2. Attach the camera or enclosure to the tilt table with two 1/4-20 hex head bolts (not
supplied).
3. Position the tilt table at the desired angle and tighten the manual tilt adjustment bolts
(refer to Figure 3) to secure the table.
4. Make all camera, enclosure, and lens connections. Refer to the manuals supplied with
the equipment. Leave enough slack in the cable/wiring so that the camera, enclosure,
and lens connections do not interfere with the operation of the scanner.
SPEED SETTING
The PS20 Series scanner has selectable speed settings for 3 degrees, 6 degrees, and 12
degrees per second. The default speed setting is 6 degrees per second. To decrease or
increase the speed setting do the following:
1. Loosen the screw that secures the speed setting cover. The cover is located on the
side of the scanner (refer to Figure 3).
2. Remove the speed setting cover.
3. Set the switch to the desired speed setting.
4. Replace the cover and tighten the screw.
TILT TABLE
MANUAL TILT
ADJUSTMENT
BOLT
3
6
12
SPEED
SETTINGS
00813
LIMIT STOP
Figure 4. Scanner Adjustments and Settings
Pelco Manual C361M-A (8/02)
5
LIMIT STOP ADJUSTMENT
To set pan limit stops, perform the following steps:
1. Loosen the right and left limit stops.
2. Operate the scanner. Pan the unit to the right until the desired right pan limit is
reached.
3. Move the right limit stop to the selected position and secure in place.
4. Pan the unit to the desired left position. Slide the left limit stop to the selected position
and secure in place.
5. Pan left and right to both limit stops to check for exact positioning. Tighten both stops
securely.
To pan the scanner 380 degrees, remove one limit stop from the scanner. Only one limit
stop is removable. The other limit stop is fixed to the scanner; it can be adjusted but not
removed.
6
Pelco Manual C361M-A (8/02)
SPECIFICATIONS
MECHANICAL
Pan:
0-380° movement in horizontal plane
3°, 6°, or 12° per sec ±.5°
35 lb (16 kg) centered
Upright or inverted
Heavy-duty ball bearings
Speed:
Maximum Load:
Operation:
Bearings:
Overload Protection: Thermal protected
ELECTRICAL
Input Voltage
PS20:
PS20-24:
120 VAC
24 VAC
PS20/230:
Power Requirements
PS20:
230 VAC
0.175 A (20 vA)
PS20-24:
0.600 A (15 vA)
PS20/230:
Connectors:
Motors:
Limit Switches:
Conductors:
0.130 A (30 vA)
Wire nuts provided
Stepper motor, continuous duty, instantaneous reversing
Auto scan switching, external adjustment
7, unshielded (functions: left, right, auto, common, safety ground,
AC Line, AC Neutral)
GENERAL
Construction:
Finish:
Environment:
Unit Weight:
Aluminum
Gray polyester powder coat
Indoor/outdoor; -10° to 120°F (-23° to 49°C)
9.9 lb (4.5 kg)
Pelco Manual C361M-A (8/02)
7
REGULATORY NOTICES
This equipment has been tested and found to comply with the limits of a Class B digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try and correct the interference by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the re-
ceiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
WARRANTY AND RETURN INFORMATION
WARRANTY
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100
or (559) 292-1981 to obtain a RepairAuthorization number (RA), and provide the
following information:
Pelco will repair or replace, without charge, any merchandise proved defective in
material or workmanship for a period of one year after the date of shipment. Ex-
ceptions to this warranty are as noted below:
1. Model and serial number
•
Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and
MC3500/MC3600/MC3700 Series); two years on all other cameras.
Three years on Genex® Series (multiplexers, server, and keyboard).
Two years on cameras and all standard motorized or fixed focal length lenses.
Two years on Legacy®, Camclosure® Camera Systems, CM6700/CM6800/
CM8500/CM9500/CM9740/CM9760 Matrix, DF5 and DF8 Series Fixed Dome
products.
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
If there is a dispute regarding the warranty of a product which does not fall under
the warranty conditions stated above, please include a written explanation with
the product when returned.
•
Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in
continuous motion applications.
Method of return shipment shall be the same or equal to the method by which the
item was received by Pelco.
•
•
•
Two years on Esprit and WW5700 series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders.
One year (except video heads) on video cassette recorders (VCRs). Video heads
will be covered for a period of six months.
Six months on all pan and tilts, scanners or preset lenses used in continuous
motion applications (that is, preset scan, tour and auto scan modes).
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call
the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization num-
ber (CA number if returned for credit, and RA number if returned for repair).
•
All merchandise returned for credit may be subject to a 20% restocking and
refurbishing charge.
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to Pelco, Clovis, California. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Goods returned for repair or credit should be clearly identified with the assigned
CA or RA number and freight should be prepaid. Ship to the appropriate address
below.
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s liability
for any claim, whether based on breach of contract, negligence, infringement of
any rights of any party or product liability, relating to the Products shall not exceed
the price paid by the Dealer to Pelco for such Products. In no event will Pelco be
liable for any special, incidental or consequential damages (including loss of use,
loss of profit and claims of third parties) however caused, whether by the negligence
of Pelco or otherwise.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico:
Intermediate Consignee
American Overseas Air Freight
320 Beach Road
Burlingame, CA 94010
USA
Ultimate Consignee
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
USA
The above warranty provides the Dealer with specific legal rights. The Dealer may
also have additional rights, which are subject to variation from state to state.
REVISION HISTORY
Manual #
C361M
C361M-A
Date
6/01
8/02
Comments
Original version.
Revised installation instructions. Added certifications.
® Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.