Philips Home Security System 0150 0241B User Manual

User  
Manual  
0150-0241  
Phillips ProBridge  
 
x
Table of Contents  
1
Philips ProBridge........................................................... 4  
1.1  
Philips ProBridge Description.................................................................. 4  
Compatibility ............................................................................................. 4  
Installation Environment........................................................................... 4  
Power........................................................................................................ 5  
Installation Steps Summary..................................................................... 6  
Connection Diagrams............................................................................... 7  
1.2  
1.3  
1.4  
1.5  
1.6  
2
3
4
Cable Specifications ..................................................... 8  
Troubleshooting............................................................. 9  
Unit Settings................................................................ 10  
4.1  
Configuring ProBridge Jumpers ............................................................ 10  
5
6
Specifications.............................................................. 12  
Appendix...................................................................... 13  
6.1  
RS-485 Addressing and Connections................................................... 13  
Philip AutoDome Addressing................................................................. 14  
Using Kalatel Keypads........................................................................... 15  
AUX Operations...................................................................................... 16  
Preset Operations................................................................................... 16  
6.2  
6.3  
6.4  
6.5  
7
Warranty Information .................................................. 18  
7.1  
7.2  
7.3  
Factory Service....................................................................................... 18  
Factory Address..................................................................................... 18  
Warranty.................................................................................................. 18  
Philips ProBridge  
3
0150-0241B  
 
1Philips ProBridge  
1.1 Philips ProBridge Description  
The Kalatel CBR-PB2-PHILIPS is a specific ProBridge unit for interfacing the  
DVMRe family of digital video multiplex/recorders and providing local keyboard  
control via a CBR-KB3 or KTD-405 keypad to a Philips AutoDome.  
Kalatel Components:  
(1) CBR-PB2-PHILIPS ProBridge. This product includes:  
·
·
(1) CBR-PB2-PHILIPS ProBridge unit.  
(2) P/N 4310-0034: RJ45 to RJ45 cable. Connects the ProBridge and a  
CBR-KB3 or KTD-405 to the RS-485 Network. These cables are 6’ in  
length.  
·
·
(1) P/N 4310-0047B: Cable from PB2 to Philips Data Converter Unit  
(LTC 8780).  
(1) P/N 4010-0007: 12VDC 120VAC Power Supply or  
(1) P/N 4010-0008: 12VDC 220VAC Power Supply.  
·
(1) P/N 0150-0241A: Product Overview and Installation Manual.  
Philips Components:  
·
·
(1) Philips Data Converter Unit (LTC 8780).  
(1) Philips AutoDome.  
1.2 Compatibility  
The CBR-PB2-PHILIPS is compatible with all Kalatel DVMRe digital video  
multiplex/recorders equipped with RS-485 network capabilities except  
installations with a CBR-KB1 Keypad.  
Compatible units include the Kalatel DVMRe digital video units and various  
Kalatel Multiplexer models (Simplex, Triplex, Matrix). Please check the  
specifications of the particular Kalatel product for RS-485 network support.  
1.3 Installation Environment  
Power: Ensure that the installation site’s AC power is stable and within the rated  
voltage of the external power supply. If the site’s AC power is likely to have  
spikes or dips, use power line conditioning or an Uninterruptible Power Supply.  
Philips ProBridge  
4
0150-0241B  
 
Temperature: Observe the unit’s ambient temperature specifications when  
choosing a location for the unit. Extremes of heat or cold beyond the specified  
operating temperature limits may cause the unit to fail. Do not install this unit on  
top of other hot equipment.  
Moisture: Do not expose the unit to rain or moisture. Moisture can damage  
internal components. Do not install this unit near sources of water.  
RS485 Limitations: Total length of the RS-485 network is limited to 3000’.  
1.4 Power  
The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use  
any other power supply with this product. The manufacturer accepts no  
responsibility for damage caused by the use of any other power supply.  
Make sure installation is complete and all connections are made before applying  
power to the unit.  
4310-0007 120VAC Power Supply  
Power Supply Input  
Voltage: 120 Volt AC  
Tolerance: ±10%  
Frequency: 60 Hz  
Power Supply Output  
Voltage: 12 Volt DC  
Current: 110mA  
Power: 1.3 Watts  
Connector: 2.1mm female barrel. Center Positive  
4310-0008 220VAC Power Supply  
Power Supply Input  
Voltage: 220 Volt AC  
Tolerance: ±10%  
Frequency: 50 Hz  
Power Supply Output  
Voltage: 12 Volt DC  
Current: 110mA  
Power: 1.3 Watts  
Connector: 2.1mm female barrel. Center Positive  
Philips ProBridge  
5
0150-0241B  
 
1.5 Installation Steps Summary  
Carefully and completely read the manuals for each piece of equipment  
before attempting to install and connect this equipment.  
Before you start connecting other optional accessory equipment to your  
system, make sure that all, power, video, VCR, and monitor connections are  
completed, and everything is working correctly.  
Wire the telemetry equipment according to that unit’s installation instruction.  
Use the internal diagnostic testing capabilities of the telemetry receiver to  
verify that the power and connections to the lens and motors are correct, and  
function properly.  
Using the Diagram on the following page, connect the equipment in the  
following order:  
1. Connect the CBR-PB2-PHILIPS to the Kalatel unit (DVMRe  
Simplex, DVMRe Triplex, DVMRe Matrix) via RS-485 port using the  
RJ45 to RJ45 cable. The maximum total distance allowed on the  
RS-485 data line (without signal amplification or modems) is 3,000  
feet (1,000 meters). A 100-ohm terminator is required at each end  
of the RS-485 line.  
2. Connect the CBR-KB3 or KTD-405 keypad to the Kalatel unit  
(DVMRe Simplex, DVMRe Triplex, DVMRe Matrix) via RS-485 port  
using the RJ45 to RJ45 cable.  
3. Supply power to the Kalatel unit first and the CBR-PB2-PHILIPS  
second using the supplied AC to 12 VDC adapter. Via the Setup  
Menus for the Kalatel unit set the RS-485 network address to the  
appropriate number (see the Appendix for RS-485 addressing).  
4. Using the provided cable, connect from the ProBridge RCVR/DRVR  
port to the Philips Data Converter Unit (LTC 8780). See the Philips  
Data Converter Unit’s (LTC 8780) installation manual for  
information on connecting the LTC 8780 to the AutoDome.  
5. Set the ID addresses for the Philips Dome according to the table  
later in this manual.  
6. Via a networked connected PC with WaveReader software,  
connect to the DVMRe unit and confirm proper control and  
operation of the PTZ unit.  
Please note, that whenever the ProBridge is used with a KTD-405  
the KB3 PTZ Protocol option in the KTD-405 menu must be set to  
YES. See Supervisor Programming in the KTD-405 manual.  
NOTE  
Philips ProBridge  
6
0150-0241B  
 
1.6 Connection Diagrams  
This drawing depicts one Philips AutoDome connected via an RS485/422  
network to a Kalatel DVMReTriplex unit, that provides remote PTZ control  
over Ethernet via WaveReader software, and a CBR-KB3 or KTD-405  
keypad.  
Philips AutoDome  
DB9-F  
LTC 8780  
Data Converter Unit  
4310-0047B Cable  
Philips  
ProBridge  
RJ45  
#
RJ45  
AL  
T
A
U
1
X
A
U
X
A
U
3
X
A
U
X
2
4
1
7
1
8
1
9
2
0
1
2
6
3
7
4
2
1
2
2
2
3
2
4
5
9
8
MUX/DVMR RCVR/DVR  
2
5
2
6
2
7
2
8
10  
1
1
5
12  
B
C
D
E
2
9
3
0
3
1
3
2
1
3
14  
1
16  
{ F}  
KB3/KTD-405  
RJ45  
4310-0034B Cable  
4310-0034B Cable  
RJ45  
RJ45  
DVMRe Triplex  
Philips ProBridge  
7
0150-0241B  
 
2Cable Specifications  
ProBridge to Kalatel Unit Cable (RS-485)  
Part Number : 4310-0034B  
Pin 8: Brown  
Do Not Connect  
Pin 8: Brown  
Communication Type: RS-485  
Pin 7: Brown/White  
Pin 6: Green  
Pin 7: Brown/White  
Pin 6: Green  
Connector Type: RJ45 ,RJ45  
Pin 5: Blue/White  
Pin 4: Blue  
Pin 5: Blue/White  
Pin 4: Blue  
Cable Required: 5 Foot RJ45 to RJ45  
Triplex RS485 Cable (Supplied).  
Connects ProBridge to Triplex and  
CBR-KB3 or KTD-405 keypad.  
Pin 3: Green/White  
Pin 2: Orange  
Pin 3: Green/White  
Pin 2: Orange  
Do Not Connect  
Pin 1: Orange/White  
Pin 1: Orange/White  
RJ45  
Connector  
RJ45  
Connector  
RJ45 Connector  
RJ45 Connector  
ProBridge to Philips Data Converter Unit  
Pin 9  
Pin 8  
Pin 7  
Pin 6  
Pin 5  
Pin 4  
Pin 3  
Pin 2  
Pin 1  
Part Number : 4310-0047B  
Pin 8  
Pin 7  
Communication Type: RS232  
Pin 6  
Connector Type: RJ-45 ,DB9F  
Pin 5  
Pin 4  
Cable Required: 6 Foot RJ-45 to DB9F  
RS232 Cable (Supplied). Connects  
ProBridge to Philips Data Converter  
Pin 3  
Pin 2  
Pin 1  
Unit.  
RJ-45  
Connector  
DB-9F  
Connector  
RJ-45 Connector  
DB9F Connector  
Philips ProBridge  
8
0150-0241B  
 
3Troubleshooting  
If you are unable to verify control of the PTZ camera, please do the following:  
1. Check that each device is properly powered.  
2. Check that all cables and cable connections are correct.  
3. Verify that the Dome addresses and Unit ID are correct.  
4. If the interface still does not work correctly contact Technical Support.  
Philips ProBridge  
9
0150-0241B  
 
4 Unit Settings  
4.1 Configuring ProBridge Jumpers  
The unit ships from the factory with the correct settings for most applications and  
should not require the installer to open the unit and change the jumper settings.  
However, for trouble shooting purposes we have included the default jumper  
settings.  
Opening The ProBridge  
Place the ProBridge unit face down.  
Using a small Phillips screwdriver,  
carefully remove the screws located  
near each corner of the unit. Once  
the screws have been removed, lift  
the cover to detach.  
Identifying The Jumpers  
With the cover removed, orient the  
unit as shown here. There are two  
sets of configurable jumpers. One  
set, located on the left side of the  
board, controls how the unit  
communicates (JP2, JP3, JP4 and  
JP5). The other set, located at the  
bottom of the board (P6, twelve pin  
header) determines specific  
configuration elements for  
equipment interfacing.  
ProBridge Circuit Board  
Philips ProBridge  
10  
0150-0241B  
 
Default Jumper Settings  
The default jumper settings are listed below:  
PIN #  
JP2  
DEFAULT STATUS  
RS485 Position  
RS485 Position  
RS485 Position  
RS232 Position  
Not Installed  
Not Installed  
Installed  
JP3  
JP4  
JP5  
P6 Pin 1  
P6 Pin 2  
P6 Pin 3  
P6 Pin 4  
P6 Pin 5  
P6 Pin 6  
P6 Pin 7  
P6 Pin 8  
P6 Pin 9  
P6 Pin 10  
P6 Pin 11  
P6 Pin 12  
Not Installed  
Not Installed  
Not Installed  
Not Installed  
Not Installed  
Not Installed  
Not Installed  
Not Installed  
Not Installed  
Philips ProBridge  
11  
0150-0241B  
 
5 Specifications  
Physical  
Housing  
Plastic enclosure.  
Dimensions  
(W x L x H)  
1.5 x 4.4 x 3.3 in. (38 x 112  
x 84 mm)  
Nominal Weight  
Shipping Weight  
4.8 oz (136 g)  
1 lb (453 g) packaged, including  
the external AC power supply and  
manual.  
Color  
Light gray.  
Environmental  
Temperature  
0 to 40 °C, operating.  
Relative Humidity  
90%, non-condensing.  
Electrical  
AC Power  
Voltage Range:  
Current:  
External AC power supply included.  
110 to 240 VAC + 10%  
200 mA  
DC Power  
DC jack, positive center.  
Power Supply Voltage: 12 VDC  
Current:  
Power:  
110 mA  
1.3 W  
All specifications are subject to change without notice. Kalatel  
believes that all specifications are correct, however no liability is  
assumed for omissions or errors.  
NOTE  
Philips ProBridge  
12  
0150-0241B  
 
6Appendix  
6.1 RS-485 Addressing and Connections  
The Philips ProBridge (CBR-PB2-PHILIPS) is not an addressable  
device and requires no user settings. The device simply acts as an  
interpreter, translating the remote telemetry commands into a  
format useable by the P/T/Z controller.  
NOTE  
Each camera input, whether a fixed camera or a Pan/Tilt/Zoom (P/T/Z) unit, is  
connected to a Kalatel unit input. The Kalatel unit has an RS-485 network  
address, and so does the P/T/Z camera receiver. This address determines  
when the telemetry receiver responds to commands sent over the RS-485  
data line. Consult the PTZ installation manual for specific instructions on  
setting these addresses.  
The CBR-PB2-PHILIPS can be used in conjunction with multiple  
Kalatel units, and/or keypads controlling the domes and the Kalatel  
units. Since the ProBridge unit is a terminated device, care should  
be used when using this unit in a mixed application.  
NOTE  
The RS-485 network is a multi-drop wiring configuration of maximum length  
3,000 feet (1000 meters). RJ45 cable and RJ45 connectors are used for  
most hookups (see the installation/connection diagram). Some equipment  
manufactured by Kalatel may use flying leads, terminal blocks, or other types  
of connections.  
Most units have looping RS-485 network connectors. Either socket can be  
used. Do not use third-party RS-485 equipment without first consulting  
Kalatel Technical Support for information on compatibility with other Kalatel  
equipment.  
RS-485 Wire Specification  
#24 AWG, twisted pair with shield (2-wire).  
Less than 16 pF per foot, nominal.  
Less than 25 ohms per 100 foot, nominal.  
2-wire: Belden 9842  
4-wire: Belden 9844  
Philips ProBridge  
13  
0150-0241B  
 
6.2 Philip AutoDome Addressing  
The Philips AutoDome can be addressed from 1 to 9998. The CBR-PB2-  
PHILIPS ProBridge can control camera addresses from 1 to 9998, however  
the CBR-KB3 keyboard can control cameras from 1 to 1024. WaveReader  
software can only control cameras from 1 to 8160.  
Camera Mapping  
RS485 Network Address  
Camera Address  
1 - 32  
AutoDome Address  
0001 – 0032  
0033 – 0064  
0065 – 0096  
0097 – 0128  
0129 – 0160  
0161 – 0192  
0193 – 0224  
0225 – 0256  
0257 – 0288  
0289 – 0320  
0321 – 0352  
0253 – 0384  
0385 – 0416  
0417 – 0448  
0449 – 0480  
0481 – 0512  
0513 – 0544  
0545 – 0576  
0577 – 0608  
0609 – 0640  
0641 – 0672  
0673 – 0704  
0705 – 0736  
0737 – 0768  
001  
002  
003  
004  
005  
006  
007  
008  
009  
010  
011  
012  
013  
014  
015  
016  
017  
018  
019  
020  
021  
022  
023  
024  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
Philips ProBridge  
14  
0150-0241B  
 
RS485 Network Address  
Camera Address  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
1 – 32  
--  
AutoDome Address  
0769 – 0800  
0801 – 0832  
0833 – 0864  
0865 – 0896  
0897 – 0928  
0929 – 0960  
0961 – 0992  
0993 – 1024  
--  
025  
026  
027  
028  
029  
030  
031  
032  
--  
255  
1 – 32  
8129 – 8160  
Philips AutoDome Addresses are calculated as follows:  
NOTE  
Philips AutoDome Address = Camera Address + 32 X (Network Address – 1)  
Philips Data Converter Unit Switch Setting  
Set the switches on the LTC8780 as follows:  
S101: Switches 1, 3, and 4 set to OFF. Switch 2 set to ON.  
S102: Switches 1 –3 set on ON, switch 4 set to OFF.  
See Philips LTC8780 manual for details.  
6.3 Using Kalatel Keypads  
Keyboards (CBR-KB3/J and KTD-405) are typically used to provide initial  
configuration of the Philips AutoDome for setting addresses and presets.  
In some specific cases keyboards may be used in conjunction with  
the CBR-PB2-PHILIPS units where multiple Kalatel units are being  
NOTE  
controlled via one or more local Keyboard. Available keyboards  
are only involved when an RS-485 is configured with CBR-KB2/J,  
CBR-KB3/J and KTD-405 Keyboards. Please contact Technical  
Support for additional instructions concerning these special  
installations.  
Philips ProBridge  
15  
0150-0241B  
 
ALT Key  
Shift Key  
Aux Keys  
#
ALT  
AUX  
1
AUX  
2
AUX  
3
AUX  
4
1
7
1
8
1
9
2
0
1
5
9
2
6
3
7
4
2
1
2
2
2
3
2
4
8
2
5
2
6
2
7
2
8
B
C
D
E
10  
14  
11  
12  
16  
2
3
0
3
3
2
{
}
13 9  
15 1  
F
Preset Key  
Keyboard Layout  
6.4 AUX Operations  
The remote keyboard has 8 AUX function keys that can be assigned to do  
some Philips AutoDome features as follows:  
Remote Keypad  
Aux1 On/Off  
Fuction  
Scan  
Aux2 On/Off  
Auto Pan  
Aux3 On/Off  
Continuous Playback A Start/Stop  
Continuous Playback B Start/Stop  
Record Sequence A  
Record Sequence B  
Aux4 On/Off  
Aux5 On/Off  
Aux6 On/Off  
Aux7 Momentary  
Aux8 Momentary  
Preset Tour Start. Move Joystick to stop.  
Start Advanced Menu Mode.  
6.5 Preset Operations  
The Philips AutoDome can store up to 99 preset operations (1-99). With the  
remote keyboard, the number of presets that can be set up is 32 (1-32). With  
WaveReader, the number of presets that can be set up is 16 (1-16).  
Philips ProBridge  
16  
0150-0241B  
 
Preset Setup for CBR-KB Keyboard  
To set a new Preset position:  
1. Move the camera to the desired position by using the joystick  
or arrow keys.  
2. Press Preset key twice. The LCD will display: “Set Preshot  
Number?” Select camera key number 1 to 16 (17 to 32 with  
Shift key turned on) to set the preset number from 1 to 32.  
3. Verify by calling up that preset number: Move to another  
position then press Preset key once. The Keyboard LCD will  
display: “Go to Preshot Number?” Select the preset number to  
go to that preset position.  
To clear an existing Preset position:  
1. Press the Preset key twice. The Keyboard LCD will display:  
“Set Preshot Number?” Select the camera key to the desired  
preset number. The Dome will go to that existed Preset  
position and clear this preset.  
2. Move the Dome to the new position by using the joystick or  
arrow keys.  
3. Repeat step 1: Press Preset key twice. The KB3 LCD will  
display: “Set Preshot Number?” Select the camera key to the  
preset number. Now, the new preset position is stored.  
4. Verify by calling up that preset number: Move to another  
position then press Preset key once. The KB3 LCD will display:  
“Go to Preshot Number?” Select the preset number to go to  
that preset position.  
Preset Setup WaveReader  
To set a new Preset position:  
1. Navigate the camera to the desired location, select the  
desired preset from the drop down list box, then click Set.  
2. To send the camera to the desired preset, select the  
preset from the drop down list box, then click Go To.  
Philips ProBridge  
17  
0150-0241B  
 
7Warranty Information  
7.1 Factory Service  
If the unit requires factory service, contact the dealer who supplied the unit to you for the  
correct procedures on returning the unit to the factory or the nearest factory service center.  
If the dealer is not available, contact the manufacturer of the unit as detailed below and  
request a Return Material Authorization number (RMA). The unit’s serial number must be  
provided before an RMA number can be issued. Units returned to the factory for service  
must have freight and insurance prepaid, and must show the RMA number clearly on all  
shipping documents. The failure symptoms must be clearly described by the operator and  
enclosed with the unit together with a copy of the original supplier’s invoice. Failure to  
comply with these instructions will delay service of the unit, and may result in the unit not  
being accepted by the Repair Center.  
7.2 Factory Address  
GE Security  
Attention: Repair Center  
3050 Red Hill Ave.  
Costa Mesa, CA 92626  
United States of America  
Telephone: 800-343-3358 (7:00 AM to 4:30 PM, Pacific Time)  
In Oregon: 541-754-9133  
Fax: 541-754-7162 (24 hours a day)  
For warranty information, see the following page.  
7.3 Warranty  
GE Security warrants all of its equipment for three years from the date of purchase. This  
warranty covers any defects in materials and workmanship. Equipment failures that are due  
to improper installation, modification, abuse, or acts of nature will not be covered by this  
warranty. The repair department will evaluate all equipment returned for repair to determine  
warranty coverage. The Tech Support Manager will resolve any questions that may arise  
during evaluation to make a final determination.  
The warranty specifically covers any defects in material and workmanship and does not  
cover equipment that has been abused, damaged, or modified.  
For all warranty repairs, GE Security will cover all costs, including parts, labor, and  
shipping. Repaired equipment will be returned via the same method of shipment in which it  
was received. If a customer requests a faster return shipment, the difference will be  
charged.  
For all non-warranty repairs, the customer will be billed for parts, labor, and shipping.  
Labor will be billed in half-hour increments.  
Philips ProBridge  
18  
0150-0241B  
 
Note: Customers requesting an estimate prior to repair will be notified by phone. If they  
cannot be reached, they will be notified by fax. If we are unable to reach the contact person  
for repair authorization after one phone attempt and two fax attempts, the equipment will be  
returned without being repaired. We will hold equipment no longer than two weeks.  
Advance Replacement Policy  
When an advance replacement is required, we will send the customer replacement  
equipment from our stock and receive the returned product in exchange. The received  
equipment will be evaluated and the repair department will determine whether it is a  
warranty replacement. If it is non-warranty, see our repair policy above for details. The  
following guidelines will be used for all advance replacements:  
·
·
·
Fewer than 45 days from purchase, GE Security will replace the product with new  
equipment.  
From 45 days to 1 year from purchase, GE Security will replace the product with  
refurbished equipment.  
From 1 year to 3 years from purchase, the product must be sent in for repair.  
Advance replacements will be sent for a fee of $100.  
If you have questions about this policy, please contact GE Security’s RMA Department  
at 800-469-1676.  
Philips ProBridge  
19  
0150-0241B  
 

Paxar Calculator 1103 1110 User Manual
Peavey Electronic Keyboard 488 User Manual
Philips Cassette Player AQ6681 00 User Manual
Philips Coffeemaker II Blue US User Manual
Philips Home Theater Screen BDL4765El User Manual
Philips Surge Protector SPP2307WC User Manual
Philips TV Mount SQM5562 27 User Manual
Pioneer Speaker TSW3002D4 User Manual
Poulan Chainsaw S1634 User Manual
Powerware Power Supply 9155 User Manual