Pioneer Work Light PX 42VM5 User Manual

External Control Manual  
(for PX-42VM5/42VP5/42XM3/50XM4/61XM3)  
 
This manual shows the communication system and control commands between  
the plasma monitors and the communications control equipments.  
Contents  
Applicable models............................................................................5  
Connections..........................................................................................5  
Communication Format ..............................................................7  
Command Reference List.........................................................11  
Command ............................................................................................14  
01. Power ON..........................................................................................14  
02. Power OFF........................................................................................14  
03. Input Switch Change .......................................................................15  
04. VOLUME Gain Data........................................................................16  
05. AUDIO Mute ON..............................................................................16  
06. AUDIO Mute OFF............................................................................16  
07. CONTRAST Gain Data....................................................................17  
08. BRIGHT Gain Data .........................................................................17  
09. SHARPNESS Gain Data .................................................................18  
10. COLOR Gain Data ...........................................................................19  
11. TINT Gain Data ...............................................................................19  
12. PICTURE MODE Select..................................................................20  
13. COLOR TEMP SELECT..................................................................20  
14. RED Gain Data ................................................................................21  
15. GREEN Gain Data...........................................................................22  
16. BLUE Gain Data..............................................................................23  
17. NR MODE Set..................................................................................24  
18. BASS Gain Data...............................................................................24  
19. TREBLE Gain Data .........................................................................25  
20. BALANCE Gain Data......................................................................25  
21. SCREEN MODE Select ...................................................................26  
22. V.POSITION Gain Data...................................................................27  
2
 
23. H.POSITION Gain Data..................................................................28  
24. V-HEIGHT Gain Data......................................................................28  
25. H-WIDTH Gain Data.......................................................................29  
26. AUTO PICTURE Select...................................................................29  
27. PHASE Gain Data ...........................................................................30  
28. CLOCK Gain Data ...........................................................................30  
29. OSM Select .......................................................................................31  
30. OSM ADJ. Gain Data.......................................................................31  
31. POWER MGT Select ........................................................................32  
32. GRAY LEVEL Set ............................................................................32  
33. CINEMA MODE Set ........................................................................33  
34. LONG LIFE Set ...............................................................................33  
35. INVERSE Set ...................................................................................34  
36. SCREEN WIPER Set.......................................................................35  
37. ALL RESET ......................................................................................36  
38. Audio Select Set................................................................................36  
39. BNC INPUT .....................................................................................37  
40. RGB Select........................................................................................37  
41. HD Select..........................................................................................38  
42. LANGUAGE Select..........................................................................38  
43. COLOR SYSTEM Select..................................................................39  
44. FREQUENCY Request ....................................................................40  
45. Input MODE Request ......................................................................42  
46. VIDEO ADJ. Request.......................................................................42  
47. Audio Select Request........................................................................45  
48. Failure Mode Request......................................................................46  
49. MODEL NAME Request..................................................................47  
50. D-SUB INPUT..................................................................................49  
51. TIMER SWITCH..............................................................................49  
52. LOW TONE ......................................................................................50  
53. COLOR TUNE..................................................................................51  
54. TIMER PROGRAM SETTING........................................................52  
55. PRESENT TIME SETTING............................................................54  
56. MULTI MODE Select.......................................................................54  
58. AUTO ID SET START .....................................................................60  
59. PLE LINK.........................................................................................60  
60. VIDEO WALL SETTING.................................................................61  
3
 
61. POWER DELAY ON(at 4 or 9 multiscreen) ...................................62  
62. POWER DELAY ON (at 16 or 25 multi screens) ...........................62  
63. GAMMA GAIN Data........................................................................63  
64. Running Sense..................................................................................63  
65. ORBITER SET .................................................................................64  
66. OSM OBITER...................................................................................65  
67. OSM ANGLE ....................................................................................65  
68. Input Skip.........................................................................................65  
69. PICTURE Size..................................................................................66  
70. OPTION Select.................................................................................66  
71. REPEAT Timer.................................................................................67  
72. SERIAL No. Request........................................................................68  
73. S1/S2 SELECT .................................................................................68  
74. SOFT FOCUS...................................................................................69  
75. PLUG and PLAY(only HDCP model)..............................................69  
76. DEGITAL SIGNAL LEVEL SELECT(only HDCP model) ............70  
77. MULTI(SPRIT) SCREEN Select.....................................................70  
78. SUB PICTURE DETECT SELECT ................................................72  
79. ZOOM NAVIGATION SELECT ......................................................72  
80. PICTURE FREEZE SELECT..........................................................73  
81. PICTURE FREEZE Command .......................................................73  
82. SEAMLESS SWITCH SELECT......................................................74  
83. MULTI (SPRIT) SCREEN PROGRAM TIMER SET.....................75  
84. MULTI (SPRIT) SCREEN POWER ON MODE SET ....................77  
85. MULTI (SPRIT) REPEAT TIMER SET..........................................78  
86. OSM CONTRAST SELECT.............................................................80  
87. CC (Closed caption) SELECT..........................................................81  
88. CC (Closed caption) CONTRAST SELECT ....................................82  
4
 
Applicable models  
Company :  
Models :  
NEC Corporation  
PX-42VM5,PX-42VP5, PX-42XM3,  
PX-50XM4, PX-61XM3  
And these models support the communication commands for PD series.  
Connections  
Connections should be made as described below.  
External equipment  
plasma monitor  
e.g., Personal computer  
1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.  
Type of connector: D-Sub 9-pin male  
No. Pin Name  
1
2
3
4
5
6
7
8
9
No Connection  
RXD (Receive data)  
TXD (Transmit data)  
DTR (DTE side ready)  
GND  
DSR (DCE side ready)  
RTS (Ready to send)  
CTS (Clear to send)  
No Connection  
5
 
2) Connector on the external equipment side: Serial port (RS-232C) connector.  
See the specifications of the equipment that is to be connected for the type of  
connector and the pin assignment.  
3) Wiring  
Use a crossed (reverse) cable.  
Wire the cable so that each pair of data lines cross between the two devices.  
These data line pairs are RXD (Receive data) and TXD (Transmit data), DTR  
(DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS  
(Clear to send).  
Communication Parameters  
(1) Communication system  
(2) Interface  
Asynchronous  
RS-232C  
9600 bps  
8 bits  
(3) Baud rate  
(4) Data length  
(5) Parity  
No  
(6) Stop bit  
1 bit  
Hex  
(7) Communication code  
6
 
Communication Format  
8bit 8bit 8bit 8bit 8bit 8bit  
8bit 8bit  
Command 1  
Unit ID 1  
Unit ID 2  
Command 2  
Data length  
Data  
Check sum  
Command1  
Command 1, along with command 2, is a number used to distinguish each  
command.  
When making it operate using ID, bit1 and bit0 are set up as follows.  
Bit1,Bit0 Unit ID distinction bit  
11B  
10B  
01B  
00B  
:Usually, a form (with no ID)  
:Usually, a form (with no ID)  
:Set ID  
:Video wall ID  
In the case of ACK, when the lower order 4 bits is FH (as in 3FH and  
7FH), this indicates that the commands and data of the supported  
equipment have been received. When the lower order 4 bits is BH (as in  
3BH and 7BH), this indicates that unsupported commands and data  
have been received.  
Unit ID1,2 (UA1,UA2)  
Unit ID 1 and unit ID 2 are numbers used to identify the equipment  
that is to be connected.  
60H is used for the plasma monitor and 80H is used for external control  
equipment such as a personal computer.  
7
 
1) Unit ID 1: Indicates the equipment sending the signal. When  
supporting Set ID by the command 1, 4 bits of low ranks of Set ID are  
set up.  
2) Unit ID 2: Indicates the equipment receiving the signal. When  
supporting Set ID by the command 1, 4 bits of higher ranks of Set ID  
are set up.  
* Set ID : it is the apparatus number assigned to each plasma monitor.  
Command 2  
Command 2, along with command 1, is a number used to distinguish each  
command.  
Check Sum (CKS), Error Processing, and ACK  
1) The check sum described below and RS-232C no parity are used together for  
a check of the received data. The check sum is the lower order 8 bits of one  
frame of sent or received data comprising the sum total of Command 1, Unit  
ID 1 and 2, Command 2, Data Length, and Data.  
Check Sum Example  
DFH  
80H  
60H  
47H  
01H  
01H  
08H  
Command1  
Unit ID1  
Unit ID2  
Command2 Data Length  
Data  
Check Sum  
Total 208H  
2) Error Processing  
• When the communication interval is vacant for more than 4 ms, thereafter a  
8
 
received Command 1 will be recognized. If, at this time, meaningful data  
cannot be recognized, that data will not be recognized (as valid data).  
• An ACK will not be returned unless the receive data error, the check sum  
error, and the receive data are all taken in.  
9
 
The control method of the set by Set ID  
When controlling two or more sets of plasma monitors, if the command  
using Set ID is used, it will become controllable individually.  
The example of the POWER ON command to the plasma monitor which set  
ID as "5" is shown below.  
It is not based on ID but is the POWER ON command to all sets.  
9F 80 60 4E 00 CD  
In ID= "5", the value of ID-1=4 is set up.  
9D 84 60 4E 00 CF  
The example of a change in the single mode of a 4th page multi-system configuration and  
the multi-mode is shown below.  
ID of the set used as a master (etc PC) is set to 50, and it assumes that ID is shaken by  
AUTO ID to each set. ID shaken at each set is as follows.  
Upper left set (master) ID = 50 = 32h  
Upper right set ID = 51 = 33h  
Lower right set ID = 52 = 34h  
Lower left set ID = 53 = 35h  
Transmission Data  
DD 81 63 03 03 03 01 00 CB  
DD 82 63 03 03 03 02 00 CD  
DD 83 63 03 03 03 03 00 CF  
DD 84 63 03 03 03 04 00 D1  
Transmission of the above command performs a 4th page multi SPLIT display.  
Moreover, the following commands are published in order to change a 4th page  
multi-display into a single mode display.  
DF 80 60 03 03 01 01 00 C7  
All sets become a single mode display by the above-mentioned command.  
Since this command does not specify Set ID, all sets execute it.  
*: Control by ID may not be able to be performed depending on connection with  
external control apparatus.  
10  
 
Command Reference List  
CMD1  
CMD2  
4EH  
4FH  
47H  
7FH  
3EH  
3FH  
7FH  
7FH  
7FH  
7FH  
7FH  
0AH  
00H  
7FH  
7FH  
7FH  
C0H  
7FH  
7FH  
7FH  
51H  
7FH  
7FH  
7FH  
7FH  
7FH  
7FH  
7FH  
58H  
1AH  
1AH  
C6H  
C1H  
6BH  
C7H  
C8H  
54H  
70H  
8CH  
8BH  
8AH  
5BH  
LEN  
00H  
00H  
01H  
03H  
00H  
00H  
03H  
03H  
03H  
03H  
03H  
01H  
01H  
04H  
04H  
04H  
01H  
03H  
03H  
03H  
01H  
03H  
03H  
03H  
03H  
03H  
03H  
03H  
01H  
02H  
02H  
01H  
01H  
03H  
03H  
04H  
00H  
02H  
01H  
01H  
01H  
01H  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
Power ON  
Power OFF  
9FH  
9FH  
DFH  
DFH  
9FH  
9FH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
1FH  
DFH  
DFH  
DFH  
DFH  
DFH  
Input Switch Change  
VOLUME Gain Data  
AUDIO Mute ON  
AUDIO Mute OFF  
CONTRAST Gain Data  
BRIGHT Gain Data  
SHARPNESS Gain Data  
Color Gain Data  
TINT Gain Data  
PICTURE MODE Select  
COLOR TEMP SELECT  
RED Gain Data  
GREEN Gain Data  
BLUE Gain Data  
NR MODE Set  
BASS Gain Data  
TREBLE Gain Data  
BALANCE Gain Data  
SCREEN MODE Select  
V.POSITION Gain Data  
H.POSITION Gain Data  
V-HEIGHT Gain Data  
H-WIDTH Gain Data  
AUTO PICTURE Select  
PHASE Gain Data  
CLOCK Gain Data  
OSM Select  
OSM ADJ. Gain Data  
POWER MGT Select  
GRAY LEVEL Set  
CINEMA MODE Set  
LONG LIFE Set  
INVESE Set  
SCREEN WIPER Set  
RESET  
Audio Select Set  
BNC INPUT  
RGB Select  
HD Select  
LANGUAGE Select  
11  
 
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
COLOR SYSTEM Select  
FREQUENCY Request  
Input MODE Request  
VIDEO ADJ Request  
Audio Select Request  
Failure Mode Request  
MODEL NAME Request  
D-SUB INPUT  
DFH  
1FH  
1FH  
1FH  
1FH  
1FH  
1FH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
1FH  
5FH  
DFH  
DFH  
DFH  
5CH  
26H  
41H  
45H  
6FH  
3FH  
17H  
8DH  
02H  
0CH  
0DH  
30H  
31H  
03H  
3BH  
F0H  
F1H  
F3H  
F2H  
01H  
00H  
00H  
00H  
00H  
00H  
00H  
01H  
01H  
01H  
08H  
08H  
03H  
03H  
00H  
01H  
03H  
02H  
01H  
TIMER SWITCH  
LOW TONE  
COLOR TUNE  
TIMER PROGRAM SETTING  
PRESENT TIME SETTING  
MULTI MODE Select  
MULTI MODE Request  
AUTO ID SET START  
PLE LINK  
VIDEO WALL SETTING  
POWER DELAY ON  
(DIVIDER setting : 1/4/9)  
POWER DELAY ON  
(DIVIDER setting : 16/25)  
GAMMA Gain Data  
Running Sense  
62  
DFH  
F6H  
01H  
63  
64  
65  
66  
67  
68  
DFH  
1FH  
DFH  
DFH  
DFH  
5FH  
DFH  
DFH  
DFH  
1FH  
DFH  
DFH  
DFH  
DFH  
13H  
88H  
1EH  
5FH  
60H  
61H  
2AH  
63H  
64H  
15H  
89H  
65H  
8EH  
8FH  
04H  
00H  
04H  
01H  
01H  
01H  
01H  
04H  
06H  
00H  
01H  
01H  
01H  
01H  
ORBITTER SET  
OSM OBITER  
OSM ANGLE  
Input Skip  
69*1 PICTURE Size  
70  
71  
72  
73  
74  
75  
76  
OPTION Select  
REPEAT Timer  
SERIAL No. Request  
S1/S2 SELECT  
SOFT FOCUS  
PLUG and PLAY  
DIGITAL SIGNAL  
LEVEL SELECT  
77*1 MULTI (SPRIT) SCREEN  
Select  
DFH  
07H  
01H  
78*1 SUB.P DETECT  
79*1 ZOOM NAV  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
7AH  
7BH  
7CH  
7DH  
7EH  
32H  
01H  
01H  
01H  
01H  
03H  
0AH  
80*1 PIC FREEZE  
81*1 PAUSE COMMAND  
82*1 SEAMLESS SW  
83*1 MULTI (SPRIT) SCREEN  
PROGRAM TIMER  
12  
 
84*1 MULTI (SPRIT) SCREEN  
POWER ON MODE  
DFH  
DFH  
33H  
34H  
04H  
09H  
85*1 MULTI (SPRIT) SCREEN  
REPEAT TIMER  
86  
OSM CONTRAST  
DFH  
DFH  
37H  
3CH  
01H  
01H  
87*2 CLOSECAPTION  
(Closed Caption)  
88*2 CAPTION CONT  
DFH  
3DH  
01H  
*1:This function is only 50 or 61-inch model  
*2:This function is only A version  
13  
 
Command  
01. Power ON  
Function  
The external control equipment switches on the power of the plasma monitor.  
Transmission Data  
9FH 80H 60H 4EH 00H CKS  
ACK  
The plasma monitor returns the following ACK when the power is switched  
on.  
3FH 60H 80H 4EH 00H CKS  
NOTE: Do not set the Power ON or Power OFF command continuously.  
02. Power OFF  
Function  
The external control equipment switches off the power of the plasma monitor.  
Transmission Data  
9FH 80H 60H 4FH 00H CKS  
ACK  
The plasma monitor returns the following ACK when the power is switched  
off.  
3FH 60H 80H 4FH 00H CKS  
NOTE: Do not set the Power ON or Power OFF command continuously.  
14  
 
03. Input Switch Change  
Function  
The external control equipment switches the input of the plasma monitor.  
Transmission Data  
DFH 80H 60H 47H 01H DATA00  
DATA00 : Input Select 01H : Video1  
02H : Video2  
CKS  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2(DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
ACK  
The plasma monitor returns the following ACK when the input is switched.  
3FH 60H 80H 47H 00H CKS  
15  
 
04. VOLUME Gain Data  
Function  
The external control equipment changes the VOLUME gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00: USER SOUND Gain Flag 05H  
DATA01: VOLUME Gain Flag  
DATA02: VOLUME Gain  
01H  
00H: Step0  
:
0AH: Step10 (Default)  
:
2AH: Step42  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER SOUND Gain Flag  
DATA01: VOLUME Gain Flag  
05H  
01H  
05. AUDIO Mute ON  
Function  
The external control equipment switches on AUDIO Mute of the plasma  
monitor.  
Transmission Data  
9FH 80H 60H 3EH 00H CKS  
ACK  
3FH 60H 80H 3EH 00H CKS  
06. AUDIO Mute OFF  
Function  
The external control equipment switches off AUDIO Mute of the plasma  
monitor.  
Transmission Data  
9FH 80H 60H 3FH 00H CKS  
ACK  
3FH 60H 80H 3FH 00H CKS  
16  
 
07. CONTRAST Gain Data  
Function  
The external control equipment changes the CONTRAST gain data of the  
plasma c  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : CONTRAST Gain Flag  
DATA02 : CONTRAST Gain  
01H  
07H  
CCH : -52  
:
FFH : -01  
00H : 0  
01H : +01  
:
14H : +20  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: CONTRAST Gain Flag  
01H  
07H  
08. BRIGHT Gain Data  
Function  
The external control equipment changes the BRIGHT gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BRIGHT Gain Flag  
DATA02 : BRIGHT Gain  
01H  
08H  
E0H : -32  
:
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
17  
 
DATA00 : USER PICTURE Gain Flag  
DATA01 : BRIGHT Gain Flag  
01H  
08H  
09. SHARPNESS Gain Data  
Function  
The external control equipment changes the SHARPNESS gain data of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : SHARPNESS Gain Flag  
DATA02 : SHARPNESS Gain  
01H  
06H  
F0H : -16  
:
FFH : -01  
00H : 0  
01H : +01  
:
10H : +16  
Only when a RGB signal is connected  
DATA02 : SHARPNESS Gain  
01H : 1  
02H : 2  
03H : 3  
04H : 4  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : SHARPNESS Gain Flag  
01H  
06H  
18  
 
10. COLOR Gain Data  
Function  
The external control equipment changes the COLOR gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : COLOR Gain Flag  
DATA02 : COLOR Gain  
01H  
04H  
E0H : -32  
:
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
* COLOR Gain is from -22 (EAH) to +22 (16H) only during video.  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
01H  
DATA01 : COLOR Gain Flag  
04H  
11. TINT Gain Data  
Function  
The external control equipment changes the TINT gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : TINT Gain Flag  
DATA02 : TINT Gain  
01H  
05H  
E0H: -32  
:
* TINT Gain is from -22 (EAH) to  
+22 (16H) only during video.  
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
19  
 
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
01H  
DATA01 : TINT Gain Flag  
05H  
12. PICTURE MODE Select  
Function  
The external control equipment sets the picture mode of the plasma monitor.  
Transmission Data  
DFH 80H 60H 0AH 01H DATA00 CKS  
DATA00: 01H : NORMAL  
02H : THEATER1(It cannot choose in the still picture input of a  
personal computer.)  
03H : THEATER2(It cannot choose in the still picture input of a  
personal computer.)  
04H : Default  
05H : Bright  
ACK  
7FH 60H 80H 0AH 01H DATA00 CKS  
DATA00: 01H : NORMAL  
02H : THEATER1  
03H : THEATER2  
04H : Default  
05H : Bright  
13. COLOR TEMP SELECT  
Function  
The external control equipment changes the COLOR TEMP of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 00H 01H DATA00  
DATA00 : 00H: low  
01H: middle  
CKS  
02H: high  
03H: middle low  
20  
 
ACK  
7FH 60H 80H 00H 01H DATA00  
DATA00 : 00H: low  
01H: middle  
CKS  
02H: high  
03H: middle low  
14. RED Gain Data  
Function  
The external control equipment changes the RED Gain Data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : RED Gain Flag  
DATA02 : RED Gain1(Bias)  
01H  
01H  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
DATA03: RED Gain2(Drive)  
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : RED Gain Flag  
01H  
01H  
21  
 
15. GREEN Gain Data  
Function  
The external control equipment changes the GREEN Gain Data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : GREEN Gain Flag  
DATA02 : GREEN Gain1(Bias)  
01H  
02H  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
DATA03: GREEN Gain2(Drive)  
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: GREEN Gain Flag  
01H  
02H  
22  
 
16. BLUE Gain Data  
Function  
The external control equipment changes the BLUE Gain Data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS  
DATA00 : USER PICTURE Gain Flag  
01H  
DATA01 : BLUE Gain Flag  
03H  
DATA02 : BLUE Gain1(Bias)  
D8H :-40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H :-40  
:
DATA03: BLUE Gain2(Drive)  
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: BLUE Gain Flag  
01H  
03H  
23  
 
17. NR MODE Set  
Function  
The external control equipment sets the NR (Noise Reduction) mode of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H C0H 01H DATA00 CKS  
DATA00: 01H : NR OFF  
02H : NR-1  
03H : NR-2  
04H : NR-3  
ACK  
7FH 60H 80H C0H 01H DATA00 CKS  
DATA00: 01H : NR OFF  
02H : NR-1  
03H : NR-2  
04H : NR-3  
18. BASS Gain Data  
Function  
The external control equipment changes the BASS gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BASS Gain Flag  
DATA02 : BASS Gain  
05H  
03H  
F3H : -13  
:
FFH : -01  
00H : 0  
01H : +01  
:
0DH : +13  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BASS Gain Flag  
05H  
03H  
24  
 
19. TREBLE Gain Data  
Function  
The external control equipment changes the TREBLE gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : TREBLE Gain Flag  
DATA02 : TREBLE Gain  
05H  
04H  
F3H : -13  
:
FFH : -01  
00H : 0  
01H : +01  
:
0DH : +13  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: TREBLE Gain Flag  
05H  
04H  
20. BALANCE Gain Data  
Function  
The external control equipment changes the BALANCE gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BALANCE Gain Flag  
DATA02 : BALANCE Gain  
05H  
02H  
EAH : -22  
:
FFH : -01  
00H : 0  
01H : +01  
:
16H : +22  
ACK  
7FH 60H 80H 7FH 02H DATA00  
DATA00: USER PICTURE Gain Flag  
DATA01  
CKS  
05H  
25  
 
DATA01: BALANCE Gain Flag  
02H  
21. SCREEN MODE Select  
Function  
The external control equipment switches the screen mode of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 51H 01H DATA00 CKS  
DATA00 02H : STADIUM  
03H : ZOOM  
04H : NORMAL  
05H : FULL  
06H : REAL  
08H : UNDERSCAN  
09H : 14:9  
0AH : 2.35:1  
ACK  
7FH 60H 80H 51H 01H DATA00  
DATA00 02H : STADIUM  
03H : ZOOM  
CKS  
04H : NORMAL  
05H : FULL  
06H : REAL  
08H : UNDERSCAN  
09H : 14:9  
0AH : 2.35:1  
26  
 
22. V.POSITION Gain Data  
Function  
The external control equipment changes the V. POSITION gain data of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : V.POSITION Gain Flag  
DATA02 : V.POSITION Gain  
03H  
01H  
C0H : -64  
:
FFH : -01  
00H : 0  
01H : +01  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: V.POSITION Gain Flag  
03H  
01H  
27  
 
23. H.POSITION Gain Data  
Function  
The external control equipment changes the H. POSITION gain data of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : H.POSITION Gain Flag  
DATA02 : H.POSITION Gain  
03H  
02H  
80H : -128  
:
FFH : -01  
00H : 0  
01H : +01  
:
7FH : +127  
ACK  
7FH 60H 80H 7FH 02H DATA00  
DATA00: USER PICTURE Gain Flag  
DATA01: H.POSITION Gain Flag  
DATA01 CKS  
03H  
02H  
24. V-HEIGHT Gain Data  
Function  
The external control equipment changes the V-HEIGHT gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : V-HEIGHT Gain Flag  
DATA02 : V-HEIGHT Gain  
03H  
07H  
00H : 0  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: V-HEIGHT Gain Flag  
03H  
07H  
28  
 
25. H-WIDTH Gain Data  
Function  
The external control equipment changes the H-WIDTH gain data of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : H-WIDTH Gain Flag  
DATA02 : H-WIDTH Gain  
03H  
08H  
00H : 0  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: H-WIDTH Gain Flag  
03H  
08H  
26. AUTO PICTURE Select  
Function  
The external control equipment switches on or off the AUTO PICTURE of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00  
DATA00 : USER PICTURE Gain Flag  
DATA01 : AUTO PICTURE Select Flag  
DATA02 00H : ON  
DATA01 DATA02 CKS  
03H  
09H  
01H : OFF  
ACK  
7FH 60H 80H 7FH 03H DATA00  
DATA00 : USER PICTURE Gain Flag  
DATA01 : AUTO PICTURE Select Flag  
DATA02 00H : ON  
DATA01 DATA02 CKS  
03H  
09H  
01H : OFF  
29  
 
27. PHASE Gain Data  
Function  
The external control equipment changes the PHASE gain data (Phase) of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : PHASE Gain Flag  
DATA02 : PHASE Gain  
03H  
03H  
00H : 0  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: PHASE Gain Flag  
03H  
03H  
28. CLOCK Gain Data  
Function  
The external control equipment changes the CLOCK gain data (ratio of  
frequency division) of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : CLOCK Gain Flag  
DATA02 : CLOCK Gain  
03H  
04H  
C0H : -64  
:
FFH : -01  
00H : 0  
01H : +01  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: CLOCK Gain Flag  
03H  
04H  
30  
 
29. OSM Select  
Function  
The external control equipment switches on or off the on-screen menu (OSM) of  
the plasma monitor.  
Transmission Data  
DFH 80H 60H 58H 01H DATA00 CKS  
DATA00:  
01H: On-Screen menu On  
02H: On-Screen menu Off  
ACK  
7FH 60H 80H 58H 01H DATA00 CKS  
DATA00:  
01H: On-Screen menu On  
02H: On-Screen menu Off  
*Operation is as described in the table below.  
On-Screen Menu (OSM)  
Display of items and adjustments  
on the menu  
Volume display, input display, and  
screen size display  
Operation  
When  
menu is ON  
screen When  
screen When  
screen When  
screen  
menu is OFF menu is ON  
menu is OFF  
Remote  
control  
operation  
Personal  
computer  
control  
Yes  
Yes  
No  
Yes  
Yes  
No  
No  
No  
operation  
30. OSM ADJ. Gain Data  
Function  
The external control equipment sets the position of the OSM menu of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H 1AH 02H DATA00 DATA01 CKS  
DATA00 : OSM ADJ. Gain Flag  
02H  
DATA01  
01H : 1  
:
06H : 6  
ACK  
7FH 60H 80H 1AH 01H DATA00 CKS  
DATA00 : OSM ADJ. Gain Flag 02H  
31  
 
31. POWER MGT Select  
Function  
The external control equipment switches on or off the POWER MANAGEMENT  
of the plasma monitor.  
Transmission Data  
DFH 80H 60H 1AH 02H DATA00  
DATA01 CKS  
DATA00 : POWER MGT Select  
03H  
DATA01  
01H : ON  
02H : OFF  
ACK  
7FH 60H 80H 1AH 02H DATA00  
DATA01 CKS  
DATA00 : POWER MGT Select  
DATA01  
03H  
01H : ON  
02H : OFF  
32. GRAY LEVEL Set  
Function  
The external control equipment sets the GRAY LEVEL of the plasma monitor.  
Transmission Data  
DFH 80H 60H C6H 01H DATA00 CKS  
DATA00 : GRAY LEVEL  
00H : 0  
:
0FH : 15  
ACK  
7FH 60H 80H C6H 01H DATA00 CKS  
DATA00 : GRAY LEVEL  
00H : 0  
:
0FH : 15  
32  
 
33. CINEMA MODE Set  
Function  
The external control equipment switches on or off the CINEMA MODE of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H C1H 01H DATA00  
DATA00 : CINEMA MODE Set 01H : ON  
02H : OFF  
CKS  
ACK  
7FH 60H 80H C1H 01H DATA00  
CKS  
DATA00 : CINEMA MODE Set  
01H : ON  
02H : OFF  
34. LONG LIFE Set  
Function  
The external control equipment sets the PLE, ORBITER, and INVERSE  
(inverse of image brightness) of the plasma monitor.  
Transmission Data  
DFH 80H 60H 6BH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : PLE  
01H : AUTO  
02H : LOCK1  
03H : LOCK2  
04H : LOCK3  
01H : ON  
DATA01 : INVERSE  
02H : OFF  
03H :WHITE  
01H : AUTO1  
02H : OFF  
DATA02 : ORBITER (PICTURE SHIFT)  
03H : AUTO2  
ACK  
The plasma monitor returns the following ACK when setting the PLE,  
ORBITER, and INVERSE (inverse of image brightness):  
3FH 60H 80H 6BH 00H CKS  
33  
 
35. INVERSE Set  
Function  
The external control equipment sets the INVERSE (inverse of image  
brightness) and the WHITE of the plasma monitor.  
Transmission Data  
DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS  
DATA00: INVERSE/WHITE  
00H : No operation  
01H : ON (INVERSE)  
02H : OFF  
03H : WHITE  
DATA01 : WORKING TIME  
00H : ON  
01H: 03M (minutes)  
02H: 06M (minutes)  
:
FFH: 12H (hours) and 45M (minutes)  
01H: 03M (minutes)  
02H: 06M (minutes)  
:
DATA02 : WAITING TIME  
FFH: 12H (hours) and 45M (minutes)  
ACK  
3FH 60H 80H C7H 00H CKS  
NOTE: The WORKING TIME and the WAITING TIME can be set in  
units of 3 minutes.  
Example: 03H=9 minutes  
1EH=1 hour and 30 minutes  
34  
 
36. SCREEN WIPER Set  
Function  
The external control equipment sets the SCREEN WIPER of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H C8H 04H DATA00 to DATA03 CKS  
DATA00 : SCREEN WIPER  
DATA01 : WORKING TIME  
00H : No operation  
01H : ON  
02H : OFF  
00H : ON  
01H: 03M (minutes)  
02H: 06M (minutes)  
:
FFH: 12H (hours) and 45M (minutes)  
DATA02 : WAITING TIME  
DATA03 : SPEED  
01H: 03M (minutes)  
02H: 06M (minutes)  
:
FFH: 12H (hours) and 45M (minutes)  
01H : 1  
:
05H : 5  
ACK  
3FH 60H 80H C8H 00H CKS  
NOTE: The WORKING TIME and the WAITING TIME can be set in  
units of 3 minutes.  
Example: 03H=9 minutes  
1EH=1 hour and 30 minutes  
35  
 
37. ALL RESET  
Function  
The external control equipment resets the user adjustment of the plasma  
monitor.  
Transmission Data  
1FH 80H 60H 54H 00H CKS  
ACK  
3FH 60H 80H 54H 00H CKS  
38. Audio Select Set  
Function  
The external control equipment sets combinations of audio and video inputs for  
the plasma monitor.  
Transmission Data  
DFH 80H 60H 70H 02H DATA00 DATA01 CKS  
DATA00 : AUDIO INPUT  
01H : AUDIO1  
02H : AUDIO2  
03H : AUDIO3  
DATA01 : VISUAL INPUT  
01H : VIDEO1  
02H : VIDEO2  
03H : VIDEO3  
05H : HD(HD1 or DTV or DTV1)  
06H : HD2(DTV2)  
07H : RGB1/PC1  
08H : RGB2/PC2  
0CH : RGB3/PC3  
0DH : HD3(SCART3)  
ACK  
The plasma monitor returns the following ACK when the input is switched.  
3FH 60H 80H 70H 00H CKS  
* The plasma monitor returns “Not Available” when selecting the video input  
same as the one set at one of the AUDIO 1 to 3.  
Example:  
The plasma monitor returns “Not Available” when selecting the VIDEO1 for  
AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.  
36  
 
39. BNC INPUT  
Function  
The external control equipment sets the BNC SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 8CH 01H DATA00 CKS  
DATA00 : BNC SELECT  
01H : RGB  
02H : Component  
04H : SCART1(*:Only Europe can be chosen.)  
05H : SCART2(*:Only Europe can be chosen.)  
ACK  
The plasma monitor returns the following ACK when setting the BNC SELECT:  
7FH 60H 80H 8CH 01H DATA00 CKS  
DATA00 : BNC SELECT  
01H : RGB  
02H : Component  
04H : SCART1(*:Only Europe can be chosen.)  
05H : SCART2(*:Only Europe can be chosen.)  
40. RGB Select  
Function  
The external control equipment sets the RGB SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 8BH 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : STILL  
03H : MOTION  
04H : WIDE1  
05H : WIDE2  
06H : DTV  
07H : WIDE3  
08H : WIDE4  
ACK  
7FH 60H 80H 8BH 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : STILL  
03H : MOTION  
04H : WIDE1  
37  
 
05H : WIDE2  
06H : DTV  
07H : WIDE3  
08H : WIDE4  
41. HD Select  
Function  
The external control equipment sets the HD SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 8AH 01H DATA00 CKS  
DATA00  
01H : 1035I  
02H : 1080A  
03H : 1080B  
ACK  
7FH 60H 80H 8AH 01H DATA00 CKS  
DATA00  
01H : 1035I  
02H : 1080A  
03H : 1080B  
42. LANGUAGE Select  
Function  
The external control equipment sets the LANGUAGE SELECT of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 5BH 01H DATA00 CKS  
DATA00: 01H : ENGLISH  
02H : GERMAN  
03H : FRENCH  
04H : SPANISH  
05H : ITALIAN  
06H : SWEDISH  
07H : JAPANESE  
0AH : CHINESE  
0BHRUSSIAN  
ACK  
38  
 
7FH 60H 80H 5BH 01H DATA00 CKS  
DATA00: 01H : ENGLISH  
02H : GERMAN  
03H : FRENCH  
04H : SPANISH  
05H : ITALIAN  
06H : SWEDISH  
07H : JAPANESE  
0AH : CHINESE  
0BHRUSSIAN  
NOTE: As for the change to JAPANESE (07H), SHIP needs to be set as  
"J." When SHIP is "J", a setup of CHINESE (0AH) cannot be performed.  
43. COLOR SYSTEM Select  
Function  
The external control equipment sets the COLOR SYSTEM of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 5CH 01H DATA00 CKS  
DATA00: 01H : 3.58NTSC  
02H : 4.43NTSC  
03H : PAL  
04H : SECAM  
0AH : AUTO  
0BH : PAL60  
0DH : PAL-M  
0EH : PAL-N  
ACK  
7FH 60H 80H 5CH 01H DATA00 CKS  
DATA00: 01H : 3.58NTSC  
02H : 4.43NTSC  
03H : PAL  
04H : SECAM  
0AH : AUTO  
39  
 
0BH : PAL60  
0DH : PAL-M  
0EH : PAL-N  
44. FREQUENCY Request  
Function  
The external control equipment inquires the Horizontal frequency, Vertical  
frequency, Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution  
of the plasma monitor.  
Transmission Data  
1FH 80H 60H 26H 00H CKS  
ACK  
7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS  
Horizontal frequency  
DATA00: Integer part  
00H: 0 (No signal: 00H)  
:
FFH  
:
255  
DATA01: One decimal place 00H: 0 (No signal: 00H)  
:
09H : 9  
Vertical frequency  
DATA02: Integer part  
00H: 0 (No signal: 00H)  
:
FFH  
:
255  
DATA03: One decimal place 00H: 0 (No signal: 00H)  
:
09H  
:
9
Horizontal sync polarity  
DATA04 00H  
:
-
01H : Positive  
02H : Negative  
Vertical sync polarity  
DATA05 00H  
:
-
01H : Positive  
02H : Negative  
40  
 
MODE  
DATA06  
00H  
: No signal  
01H to 80H : RGB signal  
Identification number of PC  
mode  
81H  
82H  
83H  
84H  
85H  
86H  
87H  
88H  
89H  
A0H  
A1H  
A2H  
A3H  
A4H  
A5H  
A6H  
: Video signal 3.58NTSC  
:
:
:
:
:
:
:
:
4.43NTSC  
PAL  
PAL-M  
PAL-N  
PAL60  
SECAM  
B/W60  
B/W50  
: HD/DVD/DTV signal 480I  
:
:
:
:
:
:
480P  
576I  
576P  
720P  
1035I  
1080I  
RESOLUTION  
DATA07: Dots (Low-order byte) 00H: 0 (No signal: 00H)  
:
FFH  
255  
DATA08: Dots (High-order byte) 00H: 257 (No signal: 00H)  
:
FFH  
DATA09: Lines (Low-order byte) 00H: 0 (No signal: 00H)  
:
FFH  
255  
DATA10: Lines (High-order byte) 00H: 257 (No signal: 00H)  
:
FFH  
41  
 
45. Input MODE Request  
Function  
The display returns the current input information by the external control  
equipment’ s request.  
Transmission Data  
1FH 80H 60H 41H 00H CKS  
ACK  
7FH 60H 80H 41H 01H DATA00 CKS  
DATA00 : Input Select  
01H : Video  
02H : Video2  
03H : Video3  
04H : HD (HD1 or DTV or DTV1)  
05H : PC1  
06H : PC2  
0AH : DVD (DVD1)  
0CH : HD2 (DTV2)  
0DH : DVD2  
0EH : PC3  
0FH : DVD3(SCART3)  
46. VIDEO ADJ. Request  
Function  
The display returns the video adjustments information by the external control  
equipment’s request.  
Transmission Data  
1FH 80H 60H 45H 00H CKS  
ACK  
7FH 60H 80H 45H 0CH DATA00 to DATA0B CKS  
DATA00: RED Gain (Bias)  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
DATA01: GREEN Gain (Bias)  
D8H : -40  
42  
 
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
DATA02: BLUE Gain (Bias)  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
DATA03: COLOR Gain  
E0H : -32  
:
* COLOR Gain is from -22 (EAH) to FFH : -01  
+22 (16H) only during video.  
00H : 0  
01H : +01  
:
20H : +32  
DATA04: TINT Gain  
E0H : -32  
:
* TINT Gain is from -22 (EAH) to  
+22 (16H) only during video.  
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
DATA05: SHARPNESS Gain  
F0H : -16  
:
FFH : -01  
00H : 0  
01H : +01  
:
10H : +16  
DATA06: CONTRAST Gain  
CCH : -52  
43  
 
:
FFH : -01  
00H : 0  
01H : +01  
:
14H : +20  
DATA07: BRIGHT Gain  
E0H : -32  
:
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
DATA08: RED Gain (Drive)  
DATA09: GREEN Gain (Drive)  
DATA0A: BLUE Gain (Drive)  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
44  
 
1EH : +30  
DATA0B: COLOR TEMP SELECT 00H: low  
01H: middle  
02H: high  
03H: middle low  
47. Audio Select Request  
Function  
The external control equipment inquires the current combinations of audio and  
video inputs for the plasma monitor.  
Transmission Data  
1FH 80H 60H 6FH 00H CKS  
ACK  
The plasma monitor returns the following ACK:  
7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : AUDIO1  
01H-0CH : VISUAL INPUT DATA  
DATA01 : AUDIO2  
01H-0CH : VISUAL INPUT DATA  
DATA02 : AUDIO3  
01H-0CH : VISUAL INPUT DATA  
<VISUAL INPUT DATA>  
01H : VIDEO1  
02H : VIDEO2  
03H : VIDEO3  
05H : HD(HD1ORDTVORDTV1)  
06H : HD2(DTV2)  
07H : RGB1/PC1  
08H : RGB2/PC2  
0CH : RGB3/PC3  
0DH : HD3  
45  
 
48. Failure Mode Request  
Function  
The external control equipment inquires the detection of failures of the plasma  
monitor.  
Transmission Data  
1FH 80H 60H 3FH 00H CKS  
ACK  
The plasma monitor returns the following ACK:  
7FH 60H 80H 3FH 02H DATA00 DATA01 CKS  
DATA00: FAILURE MODE 1  
Bit 0 : PDP MODULE  
0: Abnormal  
1: Normal  
Bit 1 : 1: fixed (backup)  
Bit 2 : TEMPERATURE  
0: Abnormal  
1: Normal  
Bit 3 : FAN  
0: Abnormal  
1: Normal  
Bit 4 : TEMPERATURE SENSOR  
0: Abnormal  
1: Normal  
Bit 5 : 1: fixed (backup)  
Bit 6 : 1: fixed (backup)  
Bit 7 : 1: fixed (backup)  
DATA01: FAILURE MODE 2  
Bit 0-7 : 1: fixed (backup)  
46  
 
49. MODEL NAME Request  
Function  
The external control equipment inquires the product code of the plasma  
monitor.  
Transmission Data  
1FH 80H 60H 17H 00H CKS  
ACK  
The plasma monitor returns the following ACK:  
7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS  
DATA00 : 1st character of the product code  
DATA01 : 2nd character of the product code  
:
DATA11 : 12th character of the product code  
Received data  
00H-09H : 0-9  
80H  
81H  
82H  
83H  
84H  
85H  
86H  
87H  
96H  
: - (Hyphen)  
:
:
:
:
:
:
:
+
/
(
)
.
: (Blank)  
10H-29H : A-Z  
Corresponding  
character  
A
B
C
D
E
F
G
H
I
J
Received data (H) 10 11 12 13 14 15 16 17 18 19  
Corresponding  
character  
K
L
M
N
O
P
Q
R
S
T
Received data (H) 1A 1B 1C 1D 1E 1F 20 21 22 23  
Corresponding  
character  
U
V
W
X
Y
Z
Received data (H) 24 25 26 27 28 29  
If there are fewer than 12 characters in the product code, product code  
47  
 
would be padded right with blanks.  
Example: If the product code of your plasma monitor is “PX-42VP4G”, the  
returned codes would be as follows.  
DATA00:1FH, DATA01:27H, DATA02:80H, DATA03:04H, DATA04:02H,  
DATA05:25H, DATA06:1FH, DATA07:04H, DATA08:16H, DATA09:96H,  
DATA10:96H, DATA11:96H  
48  
 
50. D-SUB INPUT  
Function  
The external control equipment sets the D-SUB SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 8DH 01H DATA00 CKS  
DATA00 : D-SUB INPUT  
01H : RGB  
02H : SCART3(*:Only Europe can be chosen.)  
ACK  
The plasma monitor returns the following ACK when setting the D-SUB  
SELECT:  
7FH 60H 80H 8DH 01H DATA00 CKS  
DATA00 : D-SUB INPUT  
01H : RGB  
02H : SCART3(*:Only Europe can be chosen.)  
51. TIMER SWITCH  
Function  
The external control equipment sets the timer reservation of the plasma  
monitor.  
Transmission Data  
DFH 80H 60H 02H 01H DATA00 CKS  
DATA00:  
00H : Reservation OFF  
01H : Reservation ON  
ACK  
7FH 60H 80H 02H 01H DATA00 CKS  
DATA00:  
00H : Reservation OFF  
01H : Reservation ON  
49  
 
52. LOW TONE  
Function  
The external control equipment sets the dithering processing or error diffusion  
processing of the plasma monitor.  
Transmission Data  
DFH 80H 60H 0CH 01H DATA00 CKS  
DATA00:  
00H:AUTO  
01H: dithering processing(MOTION)  
02H: dithering processing (STILL)  
03H: error diffusion processing  
ACK  
7FH 60H 80H 0CH 01H DATA00 CKS  
DATA00:  
00H:AUTO  
01H: dithering processing (MOTION)  
02H: dithering processing (STILL)  
03H: error diffusion processing  
50  
 
53. COLOR TUNE  
Function  
External control equipment can adjust RGB each color that a plasma monitor  
wants to emphasize.  
Transmission Data  
DFH 80H 60H 0DH 07H DATA00 to DATA06 CKS  
DATA00:RED  
00H : -32  
:
20H : 0  
:
40H : +32  
DATA01:GREEN  
DATA02:BLUE  
DATA03:YELLOW  
DATA04:MAZENTA  
DATA05:CYAN  
DATA06:RESET  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : OFF  
51  
 
01H : ON  
ACK  
7FH 60H 80H 0DH 00H CKS  
54. TIMER PROGRAM SETTING  
Function  
External control apparatus sets up the timer program of a plasma monitor.  
Transmission Data  
DFH 80H 60H 30H 08H DATA00 to DATA07 CKS  
DATA00 PROGRAM No  
01H~07H  
DATA01 DATE  
01H~07H  
08H  
:No1~No7  
: Sunday - Saturday  
: Every day  
09H~0FH  
: Every week Sunday - every week Saturday  
FFH : - (with No Setup)  
DATA02 ON time (HOUR)  
00H~09H  
10H~19H  
20H~23H  
:00~09  
:10~19  
:20~23  
FFH : - (with No Setup)  
DATA03 ON time (MIN)  
00H~09H  
10H~19H  
20H~29H  
30H~39H  
40H~49H  
50H~59H  
:00~09  
:10~19  
:20~29  
:30~39  
:40~49  
:50~59  
FFH : - (with No Setup)  
DATA04 OFF time (HOUR)  
00H~09H  
10H~19H  
20H~23H  
:00~09  
:10~19  
:20~23  
FFH : - (with No Setup)  
DATA05 OFF time(MIN)  
00H~09H  
:00~09  
52  
 
10H~19H  
20H~29H  
30H~39H  
40H~49H  
50H~59H  
:10~19  
:20~29  
:30~39  
:40~49  
:50~59  
FFH : - (with No Setup)  
DATA06 INPUT  
01H  
02H  
03H  
04H  
05H  
06H  
07H  
08H  
09H  
FFH  
: Video1  
: Video2  
: Video3  
: HD1(HD1 or DTV or DTV1)  
: HD2(DTV2 or SCART1/SCART2)  
: RGB1  
: RGB2  
: RGB3  
: HD3(SCART3)  
: - (with No Setup)  
DATA07 MODE  
01H  
02H  
03H  
04H  
: OBIT  
: INV  
: WT  
: WIPER  
FFH : - (with No Setup)  
ACK  
7FH 60H 80H 30H 00H CKS  
53  
 
55. PRESENT TIME SETTING  
Function  
External control apparatus sets up the present time of a plasma monitor.  
Transmission Data  
DFH 80H 60H 31H 03H DATA00 to DATA02 CKS  
DATA00 Day of the week 01H-07H : 1-7 (Sunday - Saturday)  
DATA01 HOUR  
DATA02 minute  
00H-09H:00-09  
10H~19H:10~19  
20H~23H:20~23  
00H-09H:00-09  
10H~19H:10~19  
20H~29H:20~29  
30H~39H:30~39  
40H~49H:40~49  
50H~59H:50~59  
ACK  
7FH 60H 80H 31H 00H CKS  
56. MULTI MODE Select  
Function  
External control apparatus changes MULTI MODE of a plasma monitor.  
Transmission Data  
DFH 80H 60H 03H 03H DATA00 DATA01 DATA02 CKS  
DATA00 (SCREEN DIVIDER SETTING)  
01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens  
05H : Multi mode 16 screens  
06H : Multi mode 25 screens  
DATA01 (POSITION OF DIVIDE)  
01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
54  
 
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle center selected (9 screens)  
0CH : Middle right selected (9 screens)  
0DH : Bottom left selected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens)  
10H : position1(16 screens, refer to figure1)  
11H : position2(16 screens, refer to figure1)  
:
18H : position9(16 screens, refer to figure1)  
19H : position10(16 screens, refer to figure1)  
:
1FH : position16 (16 screens, refer to figure1)  
20H : position1(25 screens, refer to figure2)  
21H : position2(25 screens, refer to figure2)  
:
29H : position10(25 screens, refer to figure2)  
2AH : position11(25 screens, refer to figure2)  
:
32H : position19(25 screens, refer to figure2)  
33H : position20(25 screens, refer to figure2)  
:
38H : position25(25 screens, refer to figure2)  
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10  
15  
9
11  
16  
21  
12  
17  
22  
13  
18  
23  
14  
11  
16  
12  
17  
13  
18  
14  
19  
19 20  
24 25  
Figure1  
Figure2  
DATA02 (DISP MODE)  
00H : SPLIT  
55  
 
01H : BRANKING  
ACK  
7FH 60H 80H 03H 03H DATA00 DATA01 DATA02 CKS  
DATA00 (SCREEN DIVIDER SETTING)  
01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens  
05H : Multi mode 16 screens  
06H : Multi mode 25 screens  
DATA01 (POSITION OF DIVIDE)  
01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle center selected (9 screens)  
0CH : Middle right selected (9 screens)  
0DH : Bottom left selected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens)  
10H : position1(16 screens, refer to figure1)  
11H : position2(16 screens, refer to figure1)  
:
18H : position9(16 screens, refer to figure1)  
19H : position10(16 screens, refer to figure1)  
:
1FH : position16 (16 screens, refer to figure1)  
20H : position1(25 screens, refer to figure2)  
21H : position2(25 screens, refer to figure2)  
:
29H : position10(25 screens, refer to figure2)  
56  
 
2AH : position11(25 screens, refer to figure2)  
:
32H : position19(25 screens, refer to figure2)  
33H : position20(25 screens, refer to figure2)  
:
38H : position25(25 screens, refer to figure2)  
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10  
15  
9
11  
16  
21  
12  
17  
22  
13  
18  
23  
14  
11  
16  
12  
17  
13  
18  
14  
19  
19 20  
24 25  
Figure1  
Figure2  
DATA02 (DISP MODE)  
00H : SPLIT  
01H : BRANKING  
Note) In the case of 4 screens or 9 screens video wall system and  
connecting each PDP by wired cable, please refer to No.60.”VIDEO  
WALL SETTING”.  
57  
 
57. MULTI MODE Request  
Function  
External control apparatus can know the MULTI MODE information on a  
plasma monitor.  
Transmission Data  
1FH 80H 60H 3BH 00H CKS  
ACK  
7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS  
DATA00 (SCREEN DIVIDER SETTING)  
01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens  
05H : Multi mode 16 screens  
06H : Multi mode 25 screens  
DATA01 (POSITION OF DIVIDE)  
01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle center selected (9 screens)  
0CH : Middle right selected (9 screens)  
0DH : Bottom left selected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens)  
10H : position1(16 screens, refer to figure1)  
11H : position2(16 screens, refer to figure1)  
:
18H : position9(16 screens, refer to figure1)  
19H : position10(16 screens, refer to figure1)  
:
1FH : position16 (16 screens, refer to figure1)  
58  
 
20H : position1(25 screens, refer to figure2)  
21H : position2(25 screens, refer to figure2)  
:
29H : position10(25 screens, refer to figure2)  
2AH : position11(25 screens, refer to figure2)  
:
32H : position19(25 screens, refer to figure2)  
33H : position20(25 screens, refer to figure2)  
:
38H : position25(25 screens, refer to figure2)  
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10  
15  
9
11  
16  
21  
12  
17  
22  
13  
18  
23  
14  
11  
16  
12  
17  
13  
18  
14  
19  
19 20  
24 25  
Figure1  
Figure2  
DATA02 (DISP MODE)  
00H : SPLIT  
01H : BRANKING  
59  
 
58. AUTO ID SET START  
Function  
External control apparatus sets up ID automatically to two or more plasma  
monitors.  
Transmission Data  
5FH 80H 60H F0H 01H DATA00 CKS  
DATA00  
00H~FFH: ID of a master*1 is set up.  
*: When you use it by the multi-system, please remove the link input of a  
master*1.  
*1: “Master” means the 1st set of PDP at the time of cable connection at  
the time of AUTO ID execution.  
59. PLE LINK  
Function  
External control apparatus sets up equally PLE between two or more plasma  
monitors.  
Transmission Data  
DFH 80H 60H F1H 03H DATA00 to DATA02 CKS  
DATA00 00H:PLE LINK ON  
01H:PLE LINK OFF  
DATA01 FFH  
DATA02 FFH  
*: This command is premised on the system configuration of two or more plasma  
monitor being a multi-system. When renewal of the PSC data based on this  
command is not carried out during a certain fixed period (about 2 seconds)  
during PLE LINK enforcement, each plasma monitor sets PSC data as FFH.  
Since this command is one-way traffic, there is no ACK.  
*DATA01: Please set up FFH, when you publish this command from external  
control apparatus. A master*1 sets up its own PSS data. As compared with its  
own PSS data, the plasma monitor after the master that received this command  
sets up the data of the larger one, and equips the output of a command with it.  
*DATA02: Please set up FFH, when you publish this command from external  
control apparatus. The 1st round which PSS data has not decided is FFH.  
*1: “Master” means the 1st set of PDP at the time of cable connection at  
60  
 
the time of AUTO ID execution.  
60. VIDEO WALL SETTING  
Function  
External control apparatus sets four screens or nine screens as a video  
wall.  
Transmission Data  
DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS  
DATA00:  
01H:1 screen  
(Matrix diplay function does not work.)  
04H:4 screens (2*2 video wall)  
09H:9 screens (3*3 video wall)  
00H-FFH:Master’s ID*1  
01H : Video1  
DATA 01:  
DATA 02:  
02H : Video2  
03H : Video3  
04H : HD (HD1 or DTV or DTV1)  
05H : HD2 (DTV2)  
06H : HD3 (DTV3)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
09H : RGB3 / PC3  
*: This command is used to following system.  
1. The system configuration is video wall system (4screens or 9screens).  
Then please connect each PDP by wired cable.  
In the case of 16 screens or 25 screens video wall system, please refer  
to No.56.”MULTI MODE Select”.  
2. The ID number from a master1 display is set the continuous number.  
DATA00: Specify the composition of a multi-system.  
DATA01: Set master’s ID*1.  
*1: “Master” means the 1st set of PDP at the time of cable connection at  
the time of AUTO ID execution.  
61  
 
61. POWER DELAY ON(at 4 or 9 multiscreen)  
Function  
External control apparatus attaches a time lag to two or more plasma  
monitors, and turns on a power supply.  
Transmission Data  
DFH 80H 60H F2H 01H DATA00 CKS  
DATA00: 00H-FFH: Delay time (second)  
*: This command is premised on two or more plasma monitor system  
composition being multi-systems. In command issue of master1 OSD operation,  
the value of DATA00 is 01H (1 second). This command does not have ACK for  
one-way traffic.  
*1: “Master” means the 1st set of PDP at the time of cable connection at  
the time of AUTO ID execution.  
62. POWER DELAY ON (at 16 or 25 multi screens)  
Function  
External control apparatus attaches a time lag to 10 or more plasma monitors,  
and turns on a power supply.  
Transmission Data  
DFH 80H 60H F6H 01H DATA00 CKS  
DATA00: 01H  
02H  
mode1  
mode2  
ACK  
7FH 60H 80H F6H 01H DATA00 CKS  
DATA00: 01H  
02H  
mode1  
mode2  
NOTE: When multi mode is 16 or 25, this function is available.  
62  
 
63. GAMMA GAIN Data  
Function  
External control apparatus changes Gamma of a plasma monitor.  
Transmission Data  
DFH 80H 60H 13H 02H DATA00 DATA01 CKS  
DATA00: GAMMA FLAG  
01H : Gamma change  
DATA01: GAMMA  
00H :1  
01H :2  
02H :3  
03H :4  
ACK  
7FH 60H 80H 13H 01H DATA00 CKS  
DATA00: GAMMA FLAG 01H : Gamma change  
64. Running Sense  
Function  
External control apparatus grasps the power supply state of a plasma monitor.  
A plasma monitor is made to recognize connection of PC CONTROL.  
Transmission Data  
1FH 80H 60H 88H 00H CKS  
ACK  
7FH 60H 80H 88H 01H DATA CKS  
DATA: Bit0:Connect Condition  
0: No connection  
1: Connected  
Bit1 0: Fixed  
1:-  
Bit2:Power Status  
0:POWER ON  
1:POWER OFF(STANBY)  
Bit3 0: Fixed  
Bit4 0: Fixed  
Bit5 0: Fixed  
Bit6 0: Fixed  
Bit7 0: Fixed  
63  
 
65. ORBITER SET  
Function  
A picture shift function is set up. (*1)  
Transmission Data  
DFH 80H 60H 1EH 04H DATA00 to DATA03 CKS  
DATA00: Mode  
00H : OFF  
01H : Auto 1 (*2)  
02H : Auto 2 (*3)  
03H : Manual (*4)  
DATA01: The horizontal amount of movements  
1 dot : 01H  
to  
: -  
20 dot : 14H  
DATA02: The vertical amount of movements  
One line : 01H  
to  
: -  
20 line : 14H  
DATA03: Interval of operation 1 - 5 minutes : 01H - 05H  
ACK  
7FH 60H 80H 1EH 01H DATA00 CKS  
DATA00: Mode  
00H : OFF  
01H : Auto 1  
02H : Auto 2  
03H : Manual  
(*1)A picture shift function is a function that is made to carry out rotation  
movement of the image, and mitigates printing on a screen.  
(*2)At the time of PC input, after reducing an image, a picture shift is  
performed. Reduction of an image does not carry out at the time of an  
animation input.  
(*3) At the time of PC input, after expanding an image, a picture shift is  
performed. Expansion of an image does not carry out at the time of an  
animation input.  
(*4) It is not concerned with PC input and an animation input, and expansion  
reduction of an image is not performed. It operates at intervals of the  
horizontal and vertical amount of movements specified by DATA 01-03,  
and operation.  
64  
 
66. OSM OBITER  
Function  
In order to decrease printing of a screen by OSM display, whenever it displays  
OSM, shift operation of the OSM is carried out.  
Transmission Data  
DFH 80H 60H 5FH 01H DATA00  
DATA00 01H : OBITER ON  
02H : OBITER OFF  
CKS  
ACK  
7FH 60H 80H 5FH 01H DATA00  
DATA00 01H : OBITER ON  
02H : OBITER OFF  
CKS  
67. OSM ANGLE  
Function  
The vertical display of OSM and a horizontal display are chosen.  
Transmission Data  
DFH 80H 60H 60H 01H DATA00  
CKS  
DATA00  
01H : Horizontal display  
02H : Vertical display  
ACK  
7FH 60H 80H 60H 01H DATA00  
CKS  
DATA00  
01H : Horizontal display  
02H : Vertical display  
68. Input Skip  
Function  
In a monitor's key "an input change", when there is no signal, it flies and shifts  
to the following channel.  
Transmission Data  
DFH 80H 60H 61H 01H DATA00  
DATA00 01H : ON  
CKS  
CKS  
02H : OFF  
ACK  
7FH 60H 80H 61H 01H DATA00  
DATA00 01H : ON  
02H : OFF  
65  
 
69. PICTURE Size  
Function  
Screen mode selection.  
Transmission Data  
DFH 80H 60H 2AH 01H DATA00  
DATA00 01H : ON  
CKS  
CKS  
02H : OFF  
ACK  
7FH 60H 80H 2AH 01H DATA00  
DATA00 01H : ON  
02H : OFF  
*This function is only 50 or 61-inch model.  
70. OPTION Select  
Function  
Power-on mode, a control lock, and IR remote are set up.  
Transmission Data  
DFH 80H 60H 63H 04H DATA00 to DATA03 CKS  
DATA00 : Power ON mode  
00H : LAST  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H: HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
00H : OFF  
DATA01 : Control Lock  
DATA02 : IR remote  
DATA03 : Loop Out  
01H : ON  
00H : OFF  
01H : ON  
00H : OFF  
01H : ON  
ACK  
7FH 60H 80H 63H 00H CKS  
66  
 
71. REPEAT Timer  
Function  
External control apparatus sets up the repeat timer of a plasma monitor.  
Transmission Data  
DFH 80H 60H 64H 07H DATA00 to DATA06 CKS  
DATA00  
00H :REPEAT Timer OFF  
01H :REPEAT Timer ON  
DATA01 PROGRAM 1  
01H :DIVIDER 1  
02H :DIVIDER 4  
03H :DIVIDER 9  
DATA02 SOURCE 01H :Video1  
02H :Video2  
03H :Video3  
05H :HD (HD1 or DTV-or-DTV1)  
06H :HD2 (DTV2 or SCART1/SCART2  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3 (SCART3)  
DATA03 WORK TIME  
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)  
DATA04 PROGRAM 1  
01H :DIVIDER 1  
02H :DIVIDER 4  
03H :DIVIDER 9  
DATA05 SOURCE 01H :Video1  
02H :Video2  
03H :Video3  
05H :HD (HD1 or DTV-or-DTV1)  
06H :HD2 (DTV2 or SCART1/SCART2  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3 (SCART3)  
DATA06 WORK TIME  
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)  
67  
 
ACK  
7FH 60H 80H 64H 00H CKS  
72. SERIAL No. Request  
Function  
External control apparatus read the serial number of the set recorded by  
EEPROM of a plasma display.  
Transmission Data  
1FH 80H 60H 15H 00H CKS  
ACK  
7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS  
Even DATA00-DATA11 is set up as follows.  
Setting value  
00H-09H  
96H  
:
:
0 - 9  
Blank  
10H-29H  
:
A-Z of Alphabet  
73. S1/S2 SELECT  
Function  
External control apparatus sets up the S1/S2 detection of a plasma monitor.  
Transmission Data  
DFH 80H 60H 89H 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : OFF  
ACK  
7FH 60H 80H 89H 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : OFF  
68  
 
74. SOFT FOCUS  
Function  
External control apparatus sets up the Soft Focus of a plasma monitor.  
Transmission Data  
DFH 80H 60H 65H 01H DATA00 CKS  
DATA00 01H : OFF  
02H : 1  
03H : 2  
04H : 3  
05H : 4  
ACK  
7FH 60H 80H 65H 01H DATA00 CKS  
DATA00 01H : OFF  
02H : 1  
03H : 2  
04H : 3  
05H : 4  
75. PLUG and PLAY(only HDCP model)  
Function  
External control apparatus sets up the Plug and Play of a plasma monitor.  
Transmission Data  
DFH 80H 60H 8EH 01H DATA00 CKS  
DATA00 01H : PC  
02H : STB/DVD(HDCP signal)  
ACK  
7FH 60H 80H 8EH 01H DATA00 CKS  
DATA00 01H : PC  
02H : STB/DVD(HDCP signal)  
69  
 
76. DEGITAL SIGNAL LEVEL SELECT(only HDCP model)  
Function  
External control apparatus sets up the digital signal level of a plasma monitor.  
Transmission Data  
DFH 80H 60H 8FH 01H DATA00 CKS  
DATA00 01H : LOW  
02H : HIGH  
ACK  
7FH 60H 80H 8FH 01H DATA00 CKS  
DATA00 01H : LOW  
02H : HIGH  
77. MULTI(SPRIT) SCREEN Select  
Function  
External control apparatus selects a screen mode from alternatives  
mentioned below, such as single mode, side-by-side, picture in picture,  
etc., of Plasma Monitor.  
Transmission Data  
DFH 80H 60H 07H 01H DATA00 CKS  
DATA00: 00H: Single Screen  
01H: Side by Side 1 (Same Size Screen)  
02H: Side-by-Side 2R (Left Screen smaller)  
03H: Picture in Picture 1 (sub screen Bottom Left) with size1  
04H: Picture in Picture2(sub screen Bottom Right) with size1  
05H: Side-by-Side 2L (Left Screen Bigger)  
06H: Picture in Picture 1(sub screen Bottom Left) with size2  
07H: Picture in Picture 2(sub screen Bottom Right) with size2  
08H: Picture in Picture 1(sub screen Bottom Left) with size3  
09H: Picture in Picture 2(sub screen Bottom Right) with size3  
0AH: Picture in Picture 1(sub screen Bottom Left) with size4  
0BH: Picture in Picture 2(sub screen Bottom Right) with size4  
41H: Picture in Picture 3(sub screen Top Right) with size1  
42H: Picture in Picture 3(sub screen Top Right) with size2  
43H: Picture in Picture 3(sub screen Top Right) with size3  
70  
 
44H: Picture in Picture 3(sub screen Top Right) with size4  
45H: Picture in Picture 4(sub screen Top Left) with size1  
46H: Picture in Picture 4(sub screen Top Left) with size2  
47H: Picture in Picture 4(sub screen Top Left) with size3  
48H: Picture in Picture 4(sub screen Top Left) with size4  
49H: Side by Side 3 (Same Size Screen vertical expand)  
4AH: Side by Side 4 R(Left Screen smaller vertical expand)  
4BH: Side by Side 4 L(Left Screen Bigger vertical expand)  
In case of Side by Side mode;  
20H: Active Left  
21H: Active Right  
In case of Picture in picture mode;  
30H: Active Main  
31H: Active Sub  
ACK  
7FH 60H 80H 07H 01H DATA00 CKS  
DATA00: 00H: Single Screen  
01H: Side by Side 1 (Same Size Screen)  
02H: Side-by-Side 2R (Left Screen smaller)  
03H: Picture in Picture 1 (sub screen Bottom Left) with size1  
04H: Picture in Picture2(sub screen Bottom Right) with size1  
05H: Side-by-Side 2L (Left Screen Bigger)  
06H: Picture in Picture 1(sub screen Bottom Left) with size2  
07H: Picture in Picture 2(sub screen Bottom Right) with size2  
08H: Picture in Picture 1(sub screen Bottom Left) with size3  
09H: Picture in Picture 2(sub screen Bottom Right) with size3  
0AH: Picture in Picture 1(sub screen Bottom Left) with size4  
0BH: Picture in Picture 2(sub screen Bottom Right) with size4  
41H: Picture in Picture 3(sub screen Top Right) with size1  
42H: Picture in Picture 3(sub screen Top Right) with size2  
43H: Picture in Picture 3(sub screen Top Right) with size3  
44H: Picture in Picture 3(sub screen Top Right) with size4  
45H: Picture in Picture 4(sub screen Top Left) with size1  
46H: Picture in Picture 4(sub screen Top Left) with size2  
47H: Picture in Picture 4(sub screen Top Left) with size3  
48H: Picture in Picture 4(sub screen Top Left) with size4  
49H: Side by Side 3 (Same Size Screen vertical expand)  
71  
 
4AH: Side-by-Side 4R (Left Screen smaller vertical expand)  
4BH: Side-by-Side 4L (Left Screen Bigger vertical expand)  
In case of Side by Side mode;  
20H: Active Left  
21H: Active Right  
In case of Picture in picture mode;  
30H: Active Main  
31H: Active Sub  
78. SUB PICTURE DETECT SELECT  
Function  
External control apparatus selects whether to display the sub picture or not,  
under picture in picture mode, of plasma monitor.  
Transmission Data  
DFH 80H 60H 7AH 01H DATA00 CKS  
DATA00 01H : OFF  
02H : AUTO  
ACK  
7FH 60H 80H 7AH 01H DATA00 CKS  
DATA00 01H : OFF  
02H : AUTO  
79. ZOOM NAVIGATION SELECT  
Function  
External control apparatus selects digital zoom display of a plasma monitor,  
from the alternatives mentioned below;  
Transmission Data  
DFH 80H 60H 7BH 01H DATA00 CKS  
DATA00  
01H : NORMAL  
02H : Side By Side(Left Screen smaller)  
03H : Picture in Picture1(Sub Screen Bottom Left)  
04H : Picture in Picture2(Sub Screen Bottom Right)  
05H : Picture in Picture3(Sub Screen Top Right)  
06H : Picture in Picture4(Sub Screen Top Left)  
ACK  
7FH 60H 80H 7BH 01H DATA00 CKS  
DATA00 01H : NORMAL  
72  
 
02H : Side-By-Side  
03H : Picture in Picture1(Sub Screen Bottom Left)  
04H : Picture in Picture2(Sub Screen Bottom Right)  
05H : Picture in Picture3(Sub Screen Top Right)  
06H : Picture in Picture4(Sub Screen Top Left)  
80. PICTURE FREEZE SELECT  
Function  
External control apparatus selects the picture freeze function of a plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7CH 01H DATA00 CKS  
DATA00 01H : OFF(single screen)  
02H : Side By Side1(Same Size Screen)  
03H : Picture in Picture1(Sub Screen Bottom Left)  
04H : Picture in Picture2(Sub Screen Bottom Right)  
05H : Picture in Picture3(Sub Screen Top Right)  
06H : Picture in Picture4(Sub Screen Top Left)  
07H: Side by Side2 (Same Size Screen vertical expand)  
ACK  
7FH 60H 80H 7CH 01H DATA00 CKS  
DATA00 01H : OFF(single screen)  
02H : Side By Side1  
03H : Picture in Picture1(Sub Screen Bottom Left)  
04H : Picture in Picture2(Sub Screen Bottom Right)  
05H : Picture in Picture3(Sub Screen Top Right)  
06H : Picture in Picture4(Sub Screen Top Left)  
07H : Side by Side2(Same Size Screen vertical expand)  
81. PICTURE FREEZE Command  
Function  
External control apparatus sets picture freeze or remove picture freeze of a  
plasma monitor.  
Transmission Data  
DFH 80H 60H 7DH 01H DATA00 CKS  
DATA00 01H : FREEZE  
02H : FREEZE OFF  
73  
 
ACK  
7FH 60H 80H 7DH 01H DATA00 CKS  
DATA00 01H : FREEZE  
02H : FREEZE OFF  
82. SEAMLESS SWITCH SELECT  
Function  
External control apparatus selects the seamless switch function of a plasma  
monitor.  
Transmission Data  
DFH 80H 60H 7EH 01H DATA00 DATA01 DATA02 CKS  
DATA00: SEAMLESS SWITCH  
01H :OFF  
02H :ON  
DATA01 : SELECT1  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
01H : Video1  
DATA02 : SELECT2  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
ACK  
7FH 60H 80H 7EH 01H DATA00 CKS  
DATA00 01H : OFF  
02H : ON  
74  
 
83. MULTI (SPRIT) SCREEN PROGRAM TIMER SET  
Function  
External control apparatus sets multi (sprit) screen program timer of a plasma  
monitor.  
Transmission Data  
DFH 80H 60H 32H 0AH DATA00DATA09 CKS  
DATA00 PROGRAM No  
DATA01 DATE  
01H07H :No1No7  
01H07H : Sunday~Saturday  
08H : Everyday  
09H0FH:Every Sunday~Every Saturday  
FFH : - (no setteing)  
DATA02 ON time(hour)  
00H09H:0009  
10H19H:1019  
20H23H:2023  
FFH : - (no setteing)  
DATA03 ON time(minute) 00H09H : 0009  
10H19H:1019  
20H29H:2029  
30H39H:3039  
40H49H:4049  
50H59H:5059  
FFH : - (no setteing)  
DATA04 OFF time(hour) 00H09H:0009  
10H19H:1019  
20H23H:2023  
FFH : - (no setting)  
DATA05 OFF time(minute)00H09H : 0009  
10H19H:1019  
20H29H:2029  
30H39H:3039  
40H49H:4049  
50H59H:5059  
FFH : - (no setteing)  
DATA06 MULTI MODE  
01H : Side By Side1(Same Size Screen)  
02H : Side By Side2(Left Screen Smaller)  
03H : Side By Side2(Left Screen Bigger)  
75  
 
04H : Picture in Picture1(Sub Screen Bottom Left)  
05H : Picture in Picture2(Sub Screen Bottom Right)  
06H : Picture in Picture3(Sub Screen Top Right)  
07H : Picture in Picture4(Sub Screen Top Left)  
DATA07 INPUT1Left or main)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
DATA08 INPUT2(Right or Sub)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
01H : ORBITER  
DATA09 MODE  
02H : INVERSE  
03H : WHITE  
04H : WIPER  
FFH : - (no setting)  
ACK  
7FH 60H 80H 30H 00H CKS  
76  
 
84. MULTI (SPRIT) SCREEN POWER ON MODE SET  
Function  
External control apparatus sets “multi (sprit) screen power on mode” of a  
plasma monitor.  
Transmission Data  
DFH 80H 60H 33H 04H DATA00DATA03 CKS  
DATA00 POWER ON MODE  
01H:LAST  
02H:MULTI  
DATA01 MULTI MODE  
01H : Side By Side1(Same Size Screen)  
02H : Side By Side2(Left Screen Smaller)  
03H : Side By Side2(Left Screen Bigger)  
04H : Picture in Picture1(Sub Screen Bottom Left)  
05H : Picture in Picture2(Sub Screen Bottom Right)  
06H : Picture in Picture3(Sub Screen Top Right)  
07H : Picture in Picture4(Sub Screen Top Left)  
DATA02 INPUT1Left or main)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
DATA03 INPUT2(Right or Sub)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
77  
 
0DH : HD3(SCART3)  
33H 00H CKS  
ACK  
7FH 60H  
80H  
85. MULTI (SPRIT) REPEAT TIMER SET  
Function  
External control apparatus sets “multi (sprit) screen repeat timer” of a plasma  
monitor.  
Transmission Data  
DFH 80H 60H 34H 09H DATA00DATA03 CKS  
DATA00 REPEAT TIMER 00H:OFF  
01H:ON  
REPEAT1  
DATA01 MULTI MODE  
00H : SINGLE  
01H : Side By Side1(Same Size Screen)  
02H : Side By Side2(Left Screen Smaller)  
03H : Side By Side2(Left Screen Bigger)  
04H : Picture in Picture1(Sub Screen Bottom Left)  
05H : Picture in Picture2(Sub Screen Bottom Right)  
06H : Picture in Picture3(Sub Screen Top Right)  
07H : Picture in Picture4(Sub Screen Top Left)  
DATA02 INPUT1Left or main)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
DATA03 INPUT2(Right or Sub)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
78  
 
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
DATA04 WORK TIME 01HFFH : 1255 minutes  
1 minutes4 hour 15 minutes)  
REPEAT2  
DATA05 MULTI MODE  
00H : SINGLE  
01H : Side By Side1(Same Size Screen)  
02H : Side By Side2(Left Screen Smaller)  
03H : Side By Side2(Left Screen Bigger)  
04H : Picture in Picture1(Sub Screen Bottom Left)  
05H : Picture in Picture2(Sub Screen Bottom Right)  
06H : Picture in Picture3(Sub Screen Top Right)  
07H : Picture in Picture4(Sub Screen Top Left)  
DATA06 INPUT1Left or main)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
0DH : HD3(SCART3)  
DATA07 INPUT2(Right or Sub)  
01H : Video1  
02H : Video2  
03H : Video3  
05H : HD (HD1 or DTV or DTV1)  
06H : HD2 (DTV2 or SCART1/SCART2)  
07H : RGB1 / PC1  
08H : RGB2 / PC2  
0CH : RGB3 / PC3  
79  
 
0DH : HD3(SCART3)  
DATA08 WORK TIME  
01HFFH : 1255 minutes  
1 minutes4 hour 15 minutes)  
NOTE: When “SINGLE” is selected at DATA01 or DATA04,  
”INPUT MODE 1” will be repeated.  
ACK  
7FH 60H  
80H  
34H  
00H  
CKS  
86. OSM CONTRAST SELECT  
Function  
External control apparatus selects the OSM contrast function of a plasma  
monitor.  
Transmission Data  
DFH 80H 60H 37H 01H DATA00 CKS  
DATA00 01H : NORMAL  
02H : LOW  
ACK  
7FH 60H 80H 37H 01H DATA00 CKS  
DATA00 01H : NORMAL  
02H : LOW  
80  
 
87. CC (Closed caption) SELECT  
Function  
External control apparatus selects the Closed Caption function of a plasma  
monitor.  
Transmission Data  
DFH 80H 60H 3CH 01H DATA00 CKS  
DATA00 00H : OFF  
01H : CC1(closed caption1)  
02H : CC2(closed caption2)  
03H : CC3(closed caption3)  
04H : CC4(closed caption4)  
05H : TEXT1  
06H : TEXT2  
07H : TEXT3  
08H : TEXT4  
ACK  
7FH 60H 80H 3CH 01H DATA00 CKS  
DATA00 00H : OFF  
01H : CC1(closed caption1)  
02H : CC2(closed caption2)  
03H : CC3(closed caption3)  
04H : CC4(closed caption4)  
05H : TEXT1  
06H : TEXT2  
07H : TEXT3  
08H : TEXT4  
81  
 
88. CC (Closed caption) CONTRAST SELECT  
Function  
External control apparatus selects the Closed Caption Contrast function of a  
plasma monitor.  
Transmission Data  
DFH 80H 60H 3DH 01H DATA00 CKS  
DATA00 01H : NORMAL  
02H : LOW  
ACK  
7FH 60H 80H 3DH 01H DATA00 CKS  
DATA00 01H : NORMAL  
02H : LOW  
82  
 

Peavey Stereo Amplifier MMA81502 User Manual
Philips Bottle Warmer SCF640 12 User Manual
Philips Garage Door Opener SRU5030 55 User Manual
Philips Indoor Furnishings 22FDF6033 User Manual
Philips Portable CD Player AQ6526 00 User Manual
Philips Remote Starter Remote Starter User Manual
Philips Speaker System AZ240717 User Manual
Philips TV Cables SWV6662 10 User Manual
Poulan Blower 115351227 User Manual
Precor Fitness Equipment AMT 835 User Manual