External Control Manual
(for PX-42VM5/42VP5/42XM3/50XM4/61XM3)
This manual shows the communication system and control commands between
the plasma monitors and the communications control equipments.
Contents
Applicable models............................................................................5
Connections..........................................................................................5
Communication Format ..............................................................7
Command Reference List.........................................................11
Command ............................................................................................14
01. Power ON..........................................................................................14
02. Power OFF........................................................................................14
03. Input Switch Change .......................................................................15
04. VOLUME Gain Data........................................................................16
05. AUDIO Mute ON..............................................................................16
06. AUDIO Mute OFF............................................................................16
07. CONTRAST Gain Data....................................................................17
08. BRIGHT Gain Data .........................................................................17
09. SHARPNESS Gain Data .................................................................18
10. COLOR Gain Data ...........................................................................19
11. TINT Gain Data ...............................................................................19
12. PICTURE MODE Select..................................................................20
13. COLOR TEMP SELECT..................................................................20
14. RED Gain Data ................................................................................21
15. GREEN Gain Data...........................................................................22
16. BLUE Gain Data..............................................................................23
17. NR MODE Set..................................................................................24
18. BASS Gain Data...............................................................................24
19. TREBLE Gain Data .........................................................................25
20. BALANCE Gain Data......................................................................25
21. SCREEN MODE Select ...................................................................26
22. V.POSITION Gain Data...................................................................27
2
23. H.POSITION Gain Data..................................................................28
24. V-HEIGHT Gain Data......................................................................28
25. H-WIDTH Gain Data.......................................................................29
26. AUTO PICTURE Select...................................................................29
27. PHASE Gain Data ...........................................................................30
28. CLOCK Gain Data ...........................................................................30
29. OSM Select .......................................................................................31
30. OSM ADJ. Gain Data.......................................................................31
31. POWER MGT Select ........................................................................32
32. GRAY LEVEL Set ............................................................................32
33. CINEMA MODE Set ........................................................................33
34. LONG LIFE Set ...............................................................................33
35. INVERSE Set ...................................................................................34
36. SCREEN WIPER Set.......................................................................35
37. ALL RESET ......................................................................................36
38. Audio Select Set................................................................................36
39. BNC INPUT .....................................................................................37
40. RGB Select........................................................................................37
41. HD Select..........................................................................................38
42. LANGUAGE Select..........................................................................38
43. COLOR SYSTEM Select..................................................................39
44. FREQUENCY Request ....................................................................40
45. Input MODE Request ......................................................................42
46. VIDEO ADJ. Request.......................................................................42
47. Audio Select Request........................................................................45
48. Failure Mode Request......................................................................46
49. MODEL NAME Request..................................................................47
50. D-SUB INPUT..................................................................................49
51. TIMER SWITCH..............................................................................49
52. LOW TONE ......................................................................................50
53. COLOR TUNE..................................................................................51
54. TIMER PROGRAM SETTING........................................................52
55. PRESENT TIME SETTING............................................................54
56. MULTI MODE Select.......................................................................54
58. AUTO ID SET START .....................................................................60
59. PLE LINK.........................................................................................60
60. VIDEO WALL SETTING.................................................................61
3
61. POWER DELAY ON(at 4 or 9 multiscreen) ...................................62
62. POWER DELAY ON (at 16 or 25 multi screens) ...........................62
63. GAMMA GAIN Data........................................................................63
64. Running Sense..................................................................................63
65. ORBITER SET .................................................................................64
66. OSM OBITER...................................................................................65
67. OSM ANGLE ....................................................................................65
68. Input Skip.........................................................................................65
69. PICTURE Size..................................................................................66
70. OPTION Select.................................................................................66
71. REPEAT Timer.................................................................................67
72. SERIAL No. Request........................................................................68
73. S1/S2 SELECT .................................................................................68
74. SOFT FOCUS...................................................................................69
75. PLUG and PLAY(only HDCP model)..............................................69
76. DEGITAL SIGNAL LEVEL SELECT(only HDCP model) ............70
77. MULTI(SPRIT) SCREEN Select.....................................................70
78. SUB PICTURE DETECT SELECT ................................................72
79. ZOOM NAVIGATION SELECT ......................................................72
80. PICTURE FREEZE SELECT..........................................................73
81. PICTURE FREEZE Command .......................................................73
82. SEAMLESS SWITCH SELECT......................................................74
83. MULTI (SPRIT) SCREEN PROGRAM TIMER SET.....................75
84. MULTI (SPRIT) SCREEN POWER ON MODE SET ....................77
85. MULTI (SPRIT) REPEAT TIMER SET..........................................78
86. OSM CONTRAST SELECT.............................................................80
87. CC (Closed caption) SELECT..........................................................81
88. CC (Closed caption) CONTRAST SELECT ....................................82
4
Applicable models
Company :
Models :
NEC Corporation
PX-42VM5,PX-42VP5, PX-42XM3,
PX-50XM4, PX-61XM3
And these models support the communication commands for PD series.
Connections
Connections should be made as described below.
External equipment
plasma monitor
e.g., Personal computer
1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.
Type of connector: D-Sub 9-pin male
No. Pin Name
1
2
3
4
5
6
7
8
9
No Connection
RXD (Receive data)
TXD (Transmit data)
DTR (DTE side ready)
GND
DSR (DCE side ready)
RTS (Ready to send)
CTS (Clear to send)
No Connection
5
2) Connector on the external equipment side: Serial port (RS-232C) connector.
See the specifications of the equipment that is to be connected for the type of
connector and the pin assignment.
3) Wiring
Use a crossed (reverse) cable.
Wire the cable so that each pair of data lines cross between the two devices.
These data line pairs are RXD (Receive data) and TXD (Transmit data), DTR
(DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS
(Clear to send).
Communication Parameters
(1) Communication system
(2) Interface
Asynchronous
RS-232C
9600 bps
8 bits
(3) Baud rate
(4) Data length
(5) Parity
No
(6) Stop bit
1 bit
Hex
(7) Communication code
6
Communication Format
8bit 8bit 8bit 8bit 8bit 8bit
8bit 8bit
Command 1
Unit ID 1
Unit ID 2
Command 2
Data length
Data
Check sum
Command1
Command 1, along with command 2, is a number used to distinguish each
command.
When making it operate using ID, bit1 and bit0 are set up as follows.
Bit1,Bit0 Unit ID distinction bit
11B
10B
01B
00B
:Usually, a form (with no ID)
:Usually, a form (with no ID)
:Set ID
:Video wall ID
In the case of ACK, when the lower order 4 bits is FH (as in 3FH and
7FH), this indicates that the commands and data of the supported
equipment have been received. When the lower order 4 bits is BH (as in
3BH and 7BH), this indicates that unsupported commands and data
have been received.
Unit ID1,2 (UA1,UA2)
Unit ID 1 and unit ID 2 are numbers used to identify the equipment
that is to be connected.
60H is used for the plasma monitor and 80H is used for external control
equipment such as a personal computer.
7
1) Unit ID 1: Indicates the equipment sending the signal. When
supporting Set ID by the command 1, 4 bits of low ranks of Set ID are
set up.
2) Unit ID 2: Indicates the equipment receiving the signal. When
supporting Set ID by the command 1, 4 bits of higher ranks of Set ID
are set up.
* Set ID : it is the apparatus number assigned to each plasma monitor.
Command 2
Command 2, along with command 1, is a number used to distinguish each
command.
Check Sum (CKS), Error Processing, and ACK
1) The check sum described below and RS-232C no parity are used together for
a check of the received data. The check sum is the lower order 8 bits of one
frame of sent or received data comprising the sum total of Command 1, Unit
ID 1 and 2, Command 2, Data Length, and Data.
Check Sum Example
DFH
80H
60H
47H
01H
01H
08H
Command1
Unit ID1
Unit ID2
Command2 Data Length
Data
Check Sum
Total 208H
2) Error Processing
• When the communication interval is vacant for more than 4 ms, thereafter a
8
received Command 1 will be recognized. If, at this time, meaningful data
cannot be recognized, that data will not be recognized (as valid data).
• An ACK will not be returned unless the receive data error, the check sum
error, and the receive data are all taken in.
9
The control method of the set by Set ID
When controlling two or more sets of plasma monitors, if the command
using Set ID is used, it will become controllable individually.
The example of the POWER ON command to the plasma monitor which set
ID as "5" is shown below.
It is not based on ID but is the POWER ON command to all sets.
9F 80 60 4E 00 CD
In ID= "5", the value of ID-1=4 is set up.
9D 84 60 4E 00 CF
The example of a change in the single mode of a 4th page multi-system configuration and
the multi-mode is shown below.
ID of the set used as a master (etc PC) is set to 50, and it assumes that ID is shaken by
AUTO ID to each set. ID shaken at each set is as follows.
Upper left set (master) ID = 50 = 32h
Upper right set ID = 51 = 33h
Lower right set ID = 52 = 34h
Lower left set ID = 53 = 35h
Transmission Data
DD 81 63 03 03 03 01 00 CB
DD 82 63 03 03 03 02 00 CD
DD 83 63 03 03 03 03 00 CF
DD 84 63 03 03 03 04 00 D1
Transmission of the above command performs a 4th page multi SPLIT display.
Moreover, the following commands are published in order to change a 4th page
multi-display into a single mode display.
DF 80 60 03 03 01 01 00 C7
All sets become a single mode display by the above-mentioned command.
Since this command does not specify Set ID, all sets execute it.
*: Control by ID may not be able to be performed depending on connection with
external control apparatus.
10
Command Reference List
CMD1
CMD2
4EH
4FH
47H
7FH
3EH
3FH
7FH
7FH
7FH
7FH
7FH
0AH
00H
7FH
7FH
7FH
C0H
7FH
7FH
7FH
51H
7FH
7FH
7FH
7FH
7FH
7FH
7FH
58H
1AH
1AH
C6H
C1H
6BH
C7H
C8H
54H
70H
8CH
8BH
8AH
5BH
LEN
00H
00H
01H
03H
00H
00H
03H
03H
03H
03H
03H
01H
01H
04H
04H
04H
01H
03H
03H
03H
01H
03H
03H
03H
03H
03H
03H
03H
01H
02H
02H
01H
01H
03H
03H
04H
00H
02H
01H
01H
01H
01H
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Power ON
Power OFF
9FH
9FH
DFH
DFH
9FH
9FH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
1FH
DFH
DFH
DFH
DFH
DFH
Input Switch Change
VOLUME Gain Data
AUDIO Mute ON
AUDIO Mute OFF
CONTRAST Gain Data
BRIGHT Gain Data
SHARPNESS Gain Data
Color Gain Data
TINT Gain Data
PICTURE MODE Select
COLOR TEMP SELECT
RED Gain Data
GREEN Gain Data
BLUE Gain Data
NR MODE Set
BASS Gain Data
TREBLE Gain Data
BALANCE Gain Data
SCREEN MODE Select
V.POSITION Gain Data
H.POSITION Gain Data
V-HEIGHT Gain Data
H-WIDTH Gain Data
AUTO PICTURE Select
PHASE Gain Data
CLOCK Gain Data
OSM Select
OSM ADJ. Gain Data
POWER MGT Select
GRAY LEVEL Set
CINEMA MODE Set
LONG LIFE Set
INVESE Set
SCREEN WIPER Set
RESET
Audio Select Set
BNC INPUT
RGB Select
HD Select
LANGUAGE Select
11
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
COLOR SYSTEM Select
FREQUENCY Request
Input MODE Request
VIDEO ADJ Request
Audio Select Request
Failure Mode Request
MODEL NAME Request
D-SUB INPUT
DFH
1FH
1FH
1FH
1FH
1FH
1FH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
1FH
5FH
DFH
DFH
DFH
5CH
26H
41H
45H
6FH
3FH
17H
8DH
02H
0CH
0DH
30H
31H
03H
3BH
F0H
F1H
F3H
F2H
01H
00H
00H
00H
00H
00H
00H
01H
01H
01H
08H
08H
03H
03H
00H
01H
03H
02H
01H
TIMER SWITCH
LOW TONE
COLOR TUNE
TIMER PROGRAM SETTING
PRESENT TIME SETTING
MULTI MODE Select
MULTI MODE Request
AUTO ID SET START
PLE LINK
VIDEO WALL SETTING
POWER DELAY ON
(DIVIDER setting : 1/4/9)
POWER DELAY ON
(DIVIDER setting : 16/25)
GAMMA Gain Data
Running Sense
62
DFH
F6H
01H
63
64
65
66
67
68
DFH
1FH
DFH
DFH
DFH
5FH
DFH
DFH
DFH
1FH
DFH
DFH
DFH
DFH
13H
88H
1EH
5FH
60H
61H
2AH
63H
64H
15H
89H
65H
8EH
8FH
04H
00H
04H
01H
01H
01H
01H
04H
06H
00H
01H
01H
01H
01H
ORBITTER SET
OSM OBITER
OSM ANGLE
Input Skip
69*1 PICTURE Size
70
71
72
73
74
75
76
OPTION Select
REPEAT Timer
SERIAL No. Request
S1/S2 SELECT
SOFT FOCUS
PLUG and PLAY
DIGITAL SIGNAL
LEVEL SELECT
77*1 MULTI (SPRIT) SCREEN
Select
DFH
07H
01H
78*1 SUB.P DETECT
79*1 ZOOM NAV
DFH
DFH
DFH
DFH
DFH
DFH
7AH
7BH
7CH
7DH
7EH
32H
01H
01H
01H
01H
03H
0AH
80*1 PIC FREEZE
81*1 PAUSE COMMAND
82*1 SEAMLESS SW
83*1 MULTI (SPRIT) SCREEN
PROGRAM TIMER
12
84*1 MULTI (SPRIT) SCREEN
POWER ON MODE
DFH
DFH
33H
34H
04H
09H
85*1 MULTI (SPRIT) SCREEN
REPEAT TIMER
86
OSM CONTRAST
DFH
DFH
37H
3CH
01H
01H
87*2 CLOSECAPTION
(Closed Caption)
88*2 CAPTION CONT
DFH
3DH
01H
*1:This function is only 50 or 61-inch model
*2:This function is only A version
13
Command
01. Power ON
Function
The external control equipment switches on the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4EH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched
on.
3FH 60H 80H 4EH 00H CKS
NOTE: Do not set the Power ON or Power OFF command continuously.
02. Power OFF
Function
The external control equipment switches off the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4FH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched
off.
3FH 60H 80H 4FH 00H CKS
NOTE: Do not set the Power ON or Power OFF command continuously.
14
03. Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH 80H 60H 47H 01H DATA00
DATA00 : Input Select 01H : Video1
02H : Video2
CKS
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2(DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 47H 00H CKS
15
04. VOLUME Gain Data
Function
The external control equipment changes the VOLUME gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER SOUND Gain Flag 05H
DATA01: VOLUME Gain Flag
DATA02: VOLUME Gain
01H
00H: Step0
:
0AH: Step10 (Default)
:
2AH: Step42
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER SOUND Gain Flag
DATA01: VOLUME Gain Flag
05H
01H
05. AUDIO Mute ON
Function
The external control equipment switches on AUDIO Mute of the plasma
monitor.
Transmission Data
9FH 80H 60H 3EH 00H CKS
ACK
3FH 60H 80H 3EH 00H CKS
06. AUDIO Mute OFF
Function
The external control equipment switches off AUDIO Mute of the plasma
monitor.
Transmission Data
9FH 80H 60H 3FH 00H CKS
ACK
3FH 60H 80H 3FH 00H CKS
16
07. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the
plasma c
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : CONTRAST Gain Flag
DATA02 : CONTRAST Gain
01H
07H
CCH : -52
:
FFH : -01
00H : 0
01H : +01
:
14H : +20
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: CONTRAST Gain Flag
01H
07H
08. BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BRIGHT Gain Flag
DATA02 : BRIGHT Gain
01H
08H
E0H : -32
:
FFH : -01
00H : 0
01H : +01
:
20H : +32
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
17
DATA00 : USER PICTURE Gain Flag
DATA01 : BRIGHT Gain Flag
01H
08H
09. SHARPNESS Gain Data
Function
The external control equipment changes the SHARPNESS gain data of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : SHARPNESS Gain Flag
DATA02 : SHARPNESS Gain
01H
06H
F0H : -16
:
FFH : -01
00H : 0
01H : +01
:
10H : +16
Only when a RGB signal is connected
DATA02 : SHARPNESS Gain
01H : 1
02H : 2
03H : 3
04H : 4
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : SHARPNESS Gain Flag
01H
06H
18
10. COLOR Gain Data
Function
The external control equipment changes the COLOR gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : COLOR Gain Flag
DATA02 : COLOR Gain
01H
04H
E0H : -32
:
FFH : -01
00H : 0
01H : +01
:
20H : +32
* COLOR Gain is from -22 (EAH) to +22 (16H) only during video.
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : COLOR Gain Flag
04H
11. TINT Gain Data
Function
The external control equipment changes the TINT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : TINT Gain Flag
DATA02 : TINT Gain
01H
05H
E0H: -32
:
* TINT Gain is from -22 (EAH) to
+22 (16H) only during video.
FFH : -01
00H : 0
01H : +01
:
20H : +32
19
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : TINT Gain Flag
05H
12. PICTURE MODE Select
Function
The external control equipment sets the picture mode of the plasma monitor.
Transmission Data
DFH 80H 60H 0AH 01H DATA00 CKS
DATA00: 01H : NORMAL
02H : THEATER1(It cannot choose in the still picture input of a
personal computer.)
03H : THEATER2(It cannot choose in the still picture input of a
personal computer.)
04H : Default
05H : Bright
ACK
7FH 60H 80H 0AH 01H DATA00 CKS
DATA00: 01H : NORMAL
02H : THEATER1
03H : THEATER2
04H : Default
05H : Bright
13. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma
monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00
DATA00 : 00H: low
01H: middle
CKS
02H: high
03H: middle low
20
ACK
7FH 60H 80H 00H 01H DATA00
DATA00 : 00H: low
01H: middle
CKS
02H: high
03H: middle low
14. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : RED Gain Flag
DATA02 : RED Gain1(Bias)
01H
01H
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
DATA03: RED Gain2(Drive)
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : RED Gain Flag
01H
01H
21
15. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : GREEN Gain Flag
DATA02 : GREEN Gain1(Bias)
01H
02H
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
DATA03: GREEN Gain2(Drive)
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: GREEN Gain Flag
01H
02H
22
16. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : BLUE Gain Flag
03H
DATA02 : BLUE Gain1(Bias)
D8H :-40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H :-40
:
DATA03: BLUE Gain2(Drive)
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: BLUE Gain Flag
01H
03H
23
17. NR MODE Set
Function
The external control equipment sets the NR (Noise Reduction) mode of the
plasma monitor.
Transmission Data
DFH 80H 60H C0H 01H DATA00 CKS
DATA00: 01H : NR OFF
02H : NR-1
03H : NR-2
04H : NR-3
ACK
7FH 60H 80H C0H 01H DATA00 CKS
DATA00: 01H : NR OFF
02H : NR-1
03H : NR-2
04H : NR-3
18. BASS Gain Data
Function
The external control equipment changes the BASS gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BASS Gain Flag
DATA02 : BASS Gain
05H
03H
F3H : -13
:
FFH : -01
00H : 0
01H : +01
:
0DH : +13
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BASS Gain Flag
05H
03H
24
19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : TREBLE Gain Flag
DATA02 : TREBLE Gain
05H
04H
F3H : -13
:
FFH : -01
00H : 0
01H : +01
:
0DH : +13
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: TREBLE Gain Flag
05H
04H
20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BALANCE Gain Flag
DATA02 : BALANCE Gain
05H
02H
EAH : -22
:
FFH : -01
00H : 0
01H : +01
:
16H : +22
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER PICTURE Gain Flag
DATA01
CKS
05H
25
DATA01: BALANCE Gain Flag
02H
21. SCREEN MODE Select
Function
The external control equipment switches the screen mode of the plasma
monitor.
Transmission Data
DFH 80H 60H 51H 01H DATA00 CKS
DATA00 02H : STADIUM
03H : ZOOM
04H : NORMAL
05H : FULL
06H : REAL
08H : UNDERSCAN
09H : 14:9
0AH : 2.35:1
ACK
7FH 60H 80H 51H 01H DATA00
DATA00 02H : STADIUM
03H : ZOOM
CKS
04H : NORMAL
05H : FULL
06H : REAL
08H : UNDERSCAN
09H : 14:9
0AH : 2.35:1
26
22. V.POSITION Gain Data
Function
The external control equipment changes the V. POSITION gain data of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : V.POSITION Gain Flag
DATA02 : V.POSITION Gain
03H
01H
C0H : -64
:
FFH : -01
00H : 0
01H : +01
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: V.POSITION Gain Flag
03H
01H
27
23. H.POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : H.POSITION Gain Flag
DATA02 : H.POSITION Gain
03H
02H
80H : -128
:
FFH : -01
00H : 0
01H : +01
:
7FH : +127
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER PICTURE Gain Flag
DATA01: H.POSITION Gain Flag
DATA01 CKS
03H
02H
24. V-HEIGHT Gain Data
Function
The external control equipment changes the V-HEIGHT gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : V-HEIGHT Gain Flag
DATA02 : V-HEIGHT Gain
03H
07H
00H : 0
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: V-HEIGHT Gain Flag
03H
07H
28
25. H-WIDTH Gain Data
Function
The external control equipment changes the H-WIDTH gain data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : H-WIDTH Gain Flag
DATA02 : H-WIDTH Gain
03H
08H
00H : 0
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: H-WIDTH Gain Flag
03H
08H
26. AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag
DATA02 00H : ON
DATA01 DATA02 CKS
03H
09H
01H : OFF
ACK
7FH 60H 80H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag
DATA02 00H : ON
DATA01 DATA02 CKS
03H
09H
01H : OFF
29
27. PHASE Gain Data
Function
The external control equipment changes the PHASE gain data (Phase) of the
plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : PHASE Gain Flag
DATA02 : PHASE Gain
03H
03H
00H : 0
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: PHASE Gain Flag
03H
03H
28. CLOCK Gain Data
Function
The external control equipment changes the CLOCK gain data (ratio of
frequency division) of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : CLOCK Gain Flag
DATA02 : CLOCK Gain
03H
04H
C0H : -64
:
FFH : -01
00H : 0
01H : +01
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: CLOCK Gain Flag
03H
04H
30
29. OSM Select
Function
The external control equipment switches on or off the on-screen menu (OSM) of
the plasma monitor.
Transmission Data
DFH 80H 60H 58H 01H DATA00 CKS
DATA00:
01H: On-Screen menu On
02H: On-Screen menu Off
ACK
7FH 60H 80H 58H 01H DATA00 CKS
DATA00:
01H: On-Screen menu On
02H: On-Screen menu Off
*Operation is as described in the table below.
On-Screen Menu (OSM)
Display of items and adjustments
on the menu
Volume display, input display, and
screen size display
Operation
When
menu is ON
screen When
screen When
screen When
screen
menu is OFF menu is ON
menu is OFF
Remote
control
operation
Personal
computer
control
Yes
Yes
No
Yes
Yes
No
No
No
operation
30. OSM ADJ. Gain Data
Function
The external control equipment sets the position of the OSM menu of the
plasma monitor.
Transmission Data
DFH 80H 60H 1AH 02H DATA00 DATA01 CKS
DATA00 : OSM ADJ. Gain Flag
02H
DATA01
01H : 1
:
06H : 6
ACK
7FH 60H 80H 1AH 01H DATA00 CKS
DATA00 : OSM ADJ. Gain Flag 02H
31
31. POWER MGT Select
Function
The external control equipment switches on or off the POWER MANAGEMENT
of the plasma monitor.
Transmission Data
DFH 80H 60H 1AH 02H DATA00
DATA01 CKS
DATA00 : POWER MGT Select
03H
DATA01
01H : ON
02H : OFF
ACK
7FH 60H 80H 1AH 02H DATA00
DATA01 CKS
DATA00 : POWER MGT Select
DATA01
03H
01H : ON
02H : OFF
32. GRAY LEVEL Set
Function
The external control equipment sets the GRAY LEVEL of the plasma monitor.
Transmission Data
DFH 80H 60H C6H 01H DATA00 CKS
DATA00 : GRAY LEVEL
00H : 0
:
0FH : 15
ACK
7FH 60H 80H C6H 01H DATA00 CKS
DATA00 : GRAY LEVEL
00H : 0
:
0FH : 15
32
33. CINEMA MODE Set
Function
The external control equipment switches on or off the CINEMA MODE of the
plasma monitor.
Transmission Data
DFH 80H 60H C1H 01H DATA00
DATA00 : CINEMA MODE Set 01H : ON
02H : OFF
CKS
ACK
7FH 60H 80H C1H 01H DATA00
CKS
DATA00 : CINEMA MODE Set
01H : ON
02H : OFF
34. LONG LIFE Set
Function
The external control equipment sets the PLE, ORBITER, and INVERSE
(inverse of image brightness) of the plasma monitor.
Transmission Data
DFH 80H 60H 6BH 03H DATA00 DATA01 DATA02 CKS
DATA00 : PLE
01H : AUTO
02H : LOCK1
03H : LOCK2
04H : LOCK3
01H : ON
DATA01 : INVERSE
02H : OFF
03H :WHITE
01H : AUTO1
02H : OFF
DATA02 : ORBITER (PICTURE SHIFT)
03H : AUTO2
ACK
The plasma monitor returns the following ACK when setting the PLE,
ORBITER, and INVERSE (inverse of image brightness):
3FH 60H 80H 6BH 00H CKS
33
35. INVERSE Set
Function
The external control equipment sets the INVERSE (inverse of image
brightness) and the WHITE of the plasma monitor.
Transmission Data
DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS
DATA00: INVERSE/WHITE
00H : No operation
01H : ON (INVERSE)
02H : OFF
03H : WHITE
DATA01 : WORKING TIME
00H : ON
01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
01H: 03M (minutes)
02H: 06M (minutes)
:
DATA02 : WAITING TIME
FFH: 12H (hours) and 45M (minutes)
ACK
3FH 60H 80H C7H 00H CKS
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes.
Example: 03H=9 minutes
1EH=1 hour and 30 minutes
34
36. SCREEN WIPER Set
Function
The external control equipment sets the SCREEN WIPER of the plasma
monitor.
Transmission Data
DFH 80H 60H C8H 04H DATA00 to DATA03 CKS
DATA00 : SCREEN WIPER
DATA01 : WORKING TIME
00H : No operation
01H : ON
02H : OFF
00H : ON
01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
DATA02 : WAITING TIME
DATA03 : SPEED
01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
01H : 1
:
05H : 5
ACK
3FH 60H 80H C8H 00H CKS
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes.
Example: 03H=9 minutes
1EH=1 hour and 30 minutes
35
37. ALL RESET
Function
The external control equipment resets the user adjustment of the plasma
monitor.
Transmission Data
1FH 80H 60H 54H 00H CKS
ACK
3FH 60H 80H 54H 00H CKS
38. Audio Select Set
Function
The external control equipment sets combinations of audio and video inputs for
the plasma monitor.
Transmission Data
DFH 80H 60H 70H 02H DATA00 DATA01 CKS
DATA00 : AUDIO INPUT
01H : AUDIO1
02H : AUDIO2
03H : AUDIO3
DATA01 : VISUAL INPUT
01H : VIDEO1
02H : VIDEO2
03H : VIDEO3
05H : HD(HD1 or DTV or DTV1)
06H : HD2(DTV2)
07H : RGB1/PC1
08H : RGB2/PC2
0CH : RGB3/PC3
0DH : HD3(SCART3)
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 70H 00H CKS
* The plasma monitor returns “Not Available” when selecting the video input
same as the one set at one of the AUDIO 1 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the VIDEO1 for
AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.
36
39. BNC INPUT
Function
The external control equipment sets the BNC SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8CH 01H DATA00 CKS
DATA00 : BNC SELECT
01H : RGB
02H : Component
04H : SCART1(*:Only Europe can be chosen.)
05H : SCART2(*:Only Europe can be chosen.)
ACK
The plasma monitor returns the following ACK when setting the BNC SELECT:
7FH 60H 80H 8CH 01H DATA00 CKS
DATA00 : BNC SELECT
01H : RGB
02H : Component
04H : SCART1(*:Only Europe can be chosen.)
05H : SCART2(*:Only Europe can be chosen.)
40. RGB Select
Function
The external control equipment sets the RGB SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8BH 01H DATA00 CKS
DATA00
01H : AUTO
02H : STILL
03H : MOTION
04H : WIDE1
05H : WIDE2
06H : DTV
07H : WIDE3
08H : WIDE4
ACK
7FH 60H 80H 8BH 01H DATA00 CKS
DATA00
01H : AUTO
02H : STILL
03H : MOTION
04H : WIDE1
37
05H : WIDE2
06H : DTV
07H : WIDE3
08H : WIDE4
41. HD Select
Function
The external control equipment sets the HD SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8AH 01H DATA00 CKS
DATA00
01H : 1035I
02H : 1080A
03H : 1080B
ACK
7FH 60H 80H 8AH 01H DATA00 CKS
DATA00
01H : 1035I
02H : 1080A
03H : 1080B
42. LANGUAGE Select
Function
The external control equipment sets the LANGUAGE SELECT of the plasma
monitor.
Transmission Data
DFH 80H 60H 5BH 01H DATA00 CKS
DATA00: 01H : ENGLISH
02H : GERMAN
03H : FRENCH
04H : SPANISH
05H : ITALIAN
06H : SWEDISH
07H : JAPANESE
0AH : CHINESE
0BH:RUSSIAN
ACK
38
7FH 60H 80H 5BH 01H DATA00 CKS
DATA00: 01H : ENGLISH
02H : GERMAN
03H : FRENCH
04H : SPANISH
05H : ITALIAN
06H : SWEDISH
07H : JAPANESE
0AH : CHINESE
0BH:RUSSIAN
NOTE: As for the change to JAPANESE (07H), SHIP needs to be set as
"J." When SHIP is "J", a setup of CHINESE (0AH) cannot be performed.
43. COLOR SYSTEM Select
Function
The external control equipment sets the COLOR SYSTEM of the plasma
monitor.
Transmission Data
DFH 80H 60H 5CH 01H DATA00 CKS
DATA00: 01H : 3.58NTSC
02H : 4.43NTSC
03H : PAL
04H : SECAM
0AH : AUTO
0BH : PAL60
0DH : PAL-M
0EH : PAL-N
ACK
7FH 60H 80H 5CH 01H DATA00 CKS
DATA00: 01H : 3.58NTSC
02H : 4.43NTSC
03H : PAL
04H : SECAM
0AH : AUTO
39
0BH : PAL60
0DH : PAL-M
0EH : PAL-N
44. FREQUENCY Request
Function
The external control equipment inquires the Horizontal frequency, Vertical
frequency, Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution
of the plasma monitor.
Transmission Data
1FH 80H 60H 26H 00H CKS
ACK
7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS
Horizontal frequency
DATA00: Integer part
00H: 0 (No signal: 00H)
:
FFH
:
255
DATA01: One decimal place 00H: 0 (No signal: 00H)
:
09H : 9
Vertical frequency
DATA02: Integer part
00H: 0 (No signal: 00H)
:
FFH
:
255
DATA03: One decimal place 00H: 0 (No signal: 00H)
:
09H
:
9
Horizontal sync polarity
DATA04 00H
:
-
01H : Positive
02H : Negative
Vertical sync polarity
DATA05 00H
:
-
01H : Positive
02H : Negative
40
MODE
DATA06
00H
: No signal
-
01H to 80H : RGB signal
Identification number of PC
mode
81H
82H
83H
84H
85H
86H
87H
88H
89H
A0H
A1H
A2H
A3H
A4H
A5H
A6H
: Video signal 3.58NTSC
:
:
:
:
:
:
:
:
4.43NTSC
PAL
PAL-M
PAL-N
PAL60
SECAM
B/W60
B/W50
: HD/DVD/DTV signal 480I
:
:
:
:
:
:
480P
576I
576P
720P
1035I
1080I
RESOLUTION
DATA07: Dots (Low-order byte) 00H: 0 (No signal: 00H)
:
FFH
255
DATA08: Dots (High-order byte) 00H: 257 (No signal: 00H)
:
FFH
DATA09: Lines (Low-order byte) 00H: 0 (No signal: 00H)
:
FFH
255
DATA10: Lines (High-order byte) 00H: 257 (No signal: 00H)
:
FFH
41
45. Input MODE Request
Function
The display returns the current input information by the external control
equipment’ s request.
Transmission Data
1FH 80H 60H 41H 00H CKS
ACK
7FH 60H 80H 41H 01H DATA00 CKS
DATA00 : Input Select
01H : Video
02H : Video2
03H : Video3
04H : HD (HD1 or DTV or DTV1)
05H : PC1
06H : PC2
0AH : DVD (DVD1)
0CH : HD2 (DTV2)
0DH : DVD2
0EH : PC3
0FH : DVD3(SCART3)
46. VIDEO ADJ. Request
Function
The display returns the video adjustments information by the external control
equipment’s request.
Transmission Data
1FH 80H 60H 45H 00H CKS
ACK
7FH 60H 80H 45H 0CH DATA00 to DATA0B CKS
DATA00: RED Gain (Bias)
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
DATA01: GREEN Gain (Bias)
D8H : -40
42
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
DATA02: BLUE Gain (Bias)
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
DATA03: COLOR Gain
E0H : -32
:
* COLOR Gain is from -22 (EAH) to FFH : -01
+22 (16H) only during video.
00H : 0
01H : +01
:
20H : +32
DATA04: TINT Gain
E0H : -32
:
* TINT Gain is from -22 (EAH) to
+22 (16H) only during video.
FFH : -01
00H : 0
01H : +01
:
20H : +32
DATA05: SHARPNESS Gain
F0H : -16
:
FFH : -01
00H : 0
01H : +01
:
10H : +16
DATA06: CONTRAST Gain
CCH : -52
43
:
FFH : -01
00H : 0
01H : +01
:
14H : +20
DATA07: BRIGHT Gain
E0H : -32
:
FFH : -01
00H : 0
01H : +01
:
20H : +32
DATA08: RED Gain (Drive)
DATA09: GREEN Gain (Drive)
DATA0A: BLUE Gain (Drive)
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
44
1EH : +30
DATA0B: COLOR TEMP SELECT 00H: low
01H: middle
02H: high
03H: middle low
47. Audio Select Request
Function
The external control equipment inquires the current combinations of audio and
video inputs for the plasma monitor.
Transmission Data
1FH 80H 60H 6FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : AUDIO1
01H-0CH : VISUAL INPUT DATA
DATA01 : AUDIO2
01H-0CH : VISUAL INPUT DATA
DATA02 : AUDIO3
01H-0CH : VISUAL INPUT DATA
<VISUAL INPUT DATA>
01H : VIDEO1
02H : VIDEO2
03H : VIDEO3
05H : HD(HD1ORDTVORDTV1)
06H : HD2(DTV2)
07H : RGB1/PC1
08H : RGB2/PC2
0CH : RGB3/PC3
0DH : HD3
45
48. Failure Mode Request
Function
The external control equipment inquires the detection of failures of the plasma
monitor.
Transmission Data
1FH 80H 60H 3FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 3FH 02H DATA00 DATA01 CKS
DATA00: FAILURE MODE 1
Bit 0 : PDP MODULE
0: Abnormal
1: Normal
Bit 1 : 1: fixed (backup)
Bit 2 : TEMPERATURE
0: Abnormal
1: Normal
Bit 3 : FAN
0: Abnormal
1: Normal
Bit 4 : TEMPERATURE SENSOR
0: Abnormal
1: Normal
Bit 5 : 1: fixed (backup)
Bit 6 : 1: fixed (backup)
Bit 7 : 1: fixed (backup)
DATA01: FAILURE MODE 2
Bit 0-7 : 1: fixed (backup)
46
49. MODEL NAME Request
Function
The external control equipment inquires the product code of the plasma
monitor.
Transmission Data
1FH 80H 60H 17H 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS
DATA00 : 1st character of the product code
DATA01 : 2nd character of the product code
:
DATA11 : 12th character of the product code
Received data
00H-09H : 0-9
80H
81H
82H
83H
84H
85H
86H
87H
96H
: - (Hyphen)
:
:
:
:
:
:
:
+
/
(
)
.
‘
: (Blank)
10H-29H : A-Z
Corresponding
character
A
B
C
D
E
F
G
H
I
J
Received data (H) 10 11 12 13 14 15 16 17 18 19
Corresponding
character
K
L
M
N
O
P
Q
R
S
T
Received data (H) 1A 1B 1C 1D 1E 1F 20 21 22 23
Corresponding
character
U
V
W
X
Y
Z
Received data (H) 24 25 26 27 28 29
If there are fewer than 12 characters in the product code, product code
47
would be padded right with blanks.
Example: If the product code of your plasma monitor is “PX-42VP4G”, the
returned codes would be as follows.
DATA00:1FH, DATA01:27H, DATA02:80H, DATA03:04H, DATA04:02H,
DATA05:25H, DATA06:1FH, DATA07:04H, DATA08:16H, DATA09:96H,
DATA10:96H, DATA11:96H
48
50. D-SUB INPUT
Function
The external control equipment sets the D-SUB SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8DH 01H DATA00 CKS
DATA00 : D-SUB INPUT
01H : RGB
02H : SCART3(*:Only Europe can be chosen.)
ACK
The plasma monitor returns the following ACK when setting the D-SUB
SELECT:
7FH 60H 80H 8DH 01H DATA00 CKS
DATA00 : D-SUB INPUT
01H : RGB
02H : SCART3(*:Only Europe can be chosen.)
51. TIMER SWITCH
Function
The external control equipment sets the timer reservation of the plasma
monitor.
Transmission Data
DFH 80H 60H 02H 01H DATA00 CKS
DATA00:
00H : Reservation OFF
01H : Reservation ON
ACK
7FH 60H 80H 02H 01H DATA00 CKS
DATA00:
00H : Reservation OFF
01H : Reservation ON
49
52. LOW TONE
Function
The external control equipment sets the dithering processing or error diffusion
processing of the plasma monitor.
Transmission Data
DFH 80H 60H 0CH 01H DATA00 CKS
DATA00:
00H:AUTO
01H: dithering processing(MOTION)
02H: dithering processing (STILL)
03H: error diffusion processing
ACK
7FH 60H 80H 0CH 01H DATA00 CKS
DATA00:
00H:AUTO
01H: dithering processing (MOTION)
02H: dithering processing (STILL)
03H: error diffusion processing
50
53. COLOR TUNE
Function
External control equipment can adjust RGB each color that a plasma monitor
wants to emphasize.
Transmission Data
DFH 80H 60H 0DH 07H DATA00 to DATA06 CKS
DATA00:RED
00H : -32
:
20H : 0
:
40H : +32
DATA01:GREEN
DATA02:BLUE
DATA03:YELLOW
DATA04:MAZENTA
DATA05:CYAN
DATA06:RESET
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : OFF
51
01H : ON
ACK
7FH 60H 80H 0DH 00H CKS
54. TIMER PROGRAM SETTING
Function
External control apparatus sets up the timer program of a plasma monitor.
Transmission Data
DFH 80H 60H 30H 08H DATA00 to DATA07 CKS
DATA00 PROGRAM No
01H~07H
DATA01 DATE
01H~07H
08H
:No1~No7
: Sunday - Saturday
: Every day
09H~0FH
: Every week Sunday - every week Saturday
FFH : - (with No Setup)
DATA02 ON time (HOUR)
00H~09H
10H~19H
20H~23H
:00~09
:10~19
:20~23
FFH : - (with No Setup)
DATA03 ON time (MIN)
00H~09H
10H~19H
20H~29H
30H~39H
40H~49H
50H~59H
:00~09
:10~19
:20~29
:30~39
:40~49
:50~59
FFH : - (with No Setup)
DATA04 OFF time (HOUR)
00H~09H
10H~19H
20H~23H
:00~09
:10~19
:20~23
FFH : - (with No Setup)
DATA05 OFF time(MIN)
00H~09H
:00~09
52
10H~19H
20H~29H
30H~39H
40H~49H
50H~59H
:10~19
:20~29
:30~39
:40~49
:50~59
FFH : - (with No Setup)
DATA06 INPUT
01H
02H
03H
04H
05H
06H
07H
08H
09H
FFH
: Video1
: Video2
: Video3
: HD1(HD1 or DTV or DTV1)
: HD2(DTV2 or SCART1/SCART2)
: RGB1
: RGB2
: RGB3
: HD3(SCART3)
: - (with No Setup)
DATA07 MODE
01H
02H
03H
04H
: OBIT
: INV
: WT
: WIPER
FFH : - (with No Setup)
ACK
7FH 60H 80H 30H 00H CKS
53
55. PRESENT TIME SETTING
Function
External control apparatus sets up the present time of a plasma monitor.
Transmission Data
DFH 80H 60H 31H 03H DATA00 to DATA02 CKS
DATA00 Day of the week 01H-07H : 1-7 (Sunday - Saturday)
DATA01 HOUR
DATA02 minute
00H-09H:00-09
10H~19H:10~19
20H~23H:20~23
00H-09H:00-09
10H~19H:10~19
20H~29H:20~29
30H~39H:30~39
40H~49H:40~49
50H~59H:50~59
ACK
7FH 60H 80H 31H 00H CKS
56. MULTI MODE Select
Function
External control apparatus changes MULTI MODE of a plasma monitor.
Transmission Data
DFH 80H 60H 03H 03H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
05H : Multi mode 16 screens
06H : Multi mode 25 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
54
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle center selected (9 screens)
0CH : Middle right selected (9 screens)
0DH : Bottom left selected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
10H : position1(16 screens, refer to figure1)
11H : position2(16 screens, refer to figure1)
:
18H : position9(16 screens, refer to figure1)
19H : position10(16 screens, refer to figure1)
:
1FH : position16 (16 screens, refer to figure1)
20H : position1(25 screens, refer to figure2)
21H : position2(25 screens, refer to figure2)
:
29H : position10(25 screens, refer to figure2)
2AH : position11(25 screens, refer to figure2)
:
32H : position19(25 screens, refer to figure2)
33H : position20(25 screens, refer to figure2)
:
38H : position25(25 screens, refer to figure2)
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10
15
9
11
16
21
12
17
22
13
18
23
14
11
16
12
17
13
18
14
19
19 20
24 25
Figure1
Figure2
DATA02 (DISP MODE)
00H : SPLIT
55
01H : BRANKING
ACK
7FH 60H 80H 03H 03H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
05H : Multi mode 16 screens
06H : Multi mode 25 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle center selected (9 screens)
0CH : Middle right selected (9 screens)
0DH : Bottom left selected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
10H : position1(16 screens, refer to figure1)
11H : position2(16 screens, refer to figure1)
:
18H : position9(16 screens, refer to figure1)
19H : position10(16 screens, refer to figure1)
:
1FH : position16 (16 screens, refer to figure1)
20H : position1(25 screens, refer to figure2)
21H : position2(25 screens, refer to figure2)
:
29H : position10(25 screens, refer to figure2)
56
2AH : position11(25 screens, refer to figure2)
:
32H : position19(25 screens, refer to figure2)
33H : position20(25 screens, refer to figure2)
:
38H : position25(25 screens, refer to figure2)
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10
15
9
11
16
21
12
17
22
13
18
23
14
11
16
12
17
13
18
14
19
19 20
24 25
Figure1
Figure2
DATA02 (DISP MODE)
00H : SPLIT
01H : BRANKING
Note) In the case of 4 screens or 9 screens video wall system and
connecting each PDP by wired cable, please refer to No.60.”VIDEO
WALL SETTING”.
57
57. MULTI MODE Request
Function
External control apparatus can know the MULTI MODE information on a
plasma monitor.
Transmission Data
1FH 80H 60H 3BH 00H CKS
ACK
7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
05H : Multi mode 16 screens
06H : Multi mode 25 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle center selected (9 screens)
0CH : Middle right selected (9 screens)
0DH : Bottom left selected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
10H : position1(16 screens, refer to figure1)
11H : position2(16 screens, refer to figure1)
:
18H : position9(16 screens, refer to figure1)
19H : position10(16 screens, refer to figure1)
:
1FH : position16 (16 screens, refer to figure1)
58
20H : position1(25 screens, refer to figure2)
21H : position2(25 screens, refer to figure2)
:
29H : position10(25 screens, refer to figure2)
2AH : position11(25 screens, refer to figure2)
:
32H : position19(25 screens, refer to figure2)
33H : position20(25 screens, refer to figure2)
:
38H : position25(25 screens, refer to figure2)
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10
15
9
11
16
21
12
17
22
13
18
23
14
11
16
12
17
13
18
14
19
19 20
24 25
Figure1
Figure2
DATA02 (DISP MODE)
00H : SPLIT
01H : BRANKING
59
58. AUTO ID SET START
Function
External control apparatus sets up ID automatically to two or more plasma
monitors.
Transmission Data
5FH 80H 60H F0H 01H DATA00 CKS
DATA00
00H~FFH: ID of a master*1 is set up.
*: When you use it by the multi-system, please remove the link input of a
master*1.
*1: “Master” means the 1st set of PDP at the time of cable connection at
the time of AUTO ID execution.
59. PLE LINK
Function
External control apparatus sets up equally PLE between two or more plasma
monitors.
Transmission Data
DFH 80H 60H F1H 03H DATA00 to DATA02 CKS
DATA00 00H:PLE LINK ON
01H:PLE LINK OFF
DATA01 FFH
DATA02 FFH
*: This command is premised on the system configuration of two or more plasma
monitor being a multi-system. When renewal of the PSC data based on this
command is not carried out during a certain fixed period (about 2 seconds)
during PLE LINK enforcement, each plasma monitor sets PSC data as FFH.
Since this command is one-way traffic, there is no ACK.
*DATA01: Please set up FFH, when you publish this command from external
control apparatus. A master*1 sets up its own PSS data. As compared with its
own PSS data, the plasma monitor after the master that received this command
sets up the data of the larger one, and equips the output of a command with it.
*DATA02: Please set up FFH, when you publish this command from external
control apparatus. The 1st round which PSS data has not decided is FFH.
*1: “Master” means the 1st set of PDP at the time of cable connection at
60
the time of AUTO ID execution.
60. VIDEO WALL SETTING
Function
External control apparatus sets four screens or nine screens as a video
wall.
Transmission Data
DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS
DATA00:
01H:1 screen
(Matrix diplay function does not work.)
04H:4 screens (2*2 video wall)
09H:9 screens (3*3 video wall)
00H-FFH:Master’s ID*1
01H : Video1
DATA 01:
DATA 02:
02H : Video2
03H : Video3
04H : HD (HD1 or DTV or DTV1)
05H : HD2 (DTV2)
06H : HD3 (DTV3)
07H : RGB1 / PC1
08H : RGB2 / PC2
09H : RGB3 / PC3
*: This command is used to following system.
1. The system configuration is video wall system (4screens or 9screens).
Then please connect each PDP by wired cable.
In the case of 16 screens or 25 screens video wall system, please refer
to No.56.”MULTI MODE Select”.
2. The ID number from a master1 display is set the continuous number.
DATA00: Specify the composition of a multi-system.
DATA01: Set master’s ID*1.
*1: “Master” means the 1st set of PDP at the time of cable connection at
the time of AUTO ID execution.
61
61. POWER DELAY ON(at 4 or 9 multiscreen)
Function
External control apparatus attaches a time lag to two or more plasma
monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F2H 01H DATA00 CKS
DATA00: 00H-FFH: Delay time (second)
*: This command is premised on two or more plasma monitor system
composition being multi-systems. In command issue of master1 OSD operation,
the value of DATA00 is 01H (1 second). This command does not have ACK for
one-way traffic.
*1: “Master” means the 1st set of PDP at the time of cable connection at
the time of AUTO ID execution.
62. POWER DELAY ON (at 16 or 25 multi screens)
Function
External control apparatus attaches a time lag to 10 or more plasma monitors,
and turns on a power supply.
Transmission Data
DFH 80H 60H F6H 01H DATA00 CKS
DATA00: 01H
02H
mode1
mode2
ACK
7FH 60H 80H F6H 01H DATA00 CKS
DATA00: 01H
02H
mode1
mode2
NOTE: When multi mode is 16 or 25, this function is available.
62
63. GAMMA GAIN Data
Function
External control apparatus changes Gamma of a plasma monitor.
Transmission Data
DFH 80H 60H 13H 02H DATA00 DATA01 CKS
DATA00: GAMMA FLAG
01H : Gamma change
DATA01: GAMMA
00H :1
01H :2
02H :3
03H :4
ACK
7FH 60H 80H 13H 01H DATA00 CKS
DATA00: GAMMA FLAG 01H : Gamma change
64. Running Sense
Function
External control apparatus grasps the power supply state of a plasma monitor.
A plasma monitor is made to recognize connection of PC CONTROL.
Transmission Data
1FH 80H 60H 88H 00H CKS
ACK
7FH 60H 80H 88H 01H DATA CKS
DATA: Bit0:Connect Condition
0: No connection
1: Connected
Bit1 0: Fixed
1:-
Bit2:Power Status
0:POWER ON
1:POWER OFF(STANBY)
Bit3 0: Fixed
Bit4 0: Fixed
Bit5 0: Fixed
Bit6 0: Fixed
Bit7 0: Fixed
63
65. ORBITER SET
Function
A picture shift function is set up. (*1)
Transmission Data
DFH 80H 60H 1EH 04H DATA00 to DATA03 CKS
DATA00: Mode
00H : OFF
01H : Auto 1 (*2)
02H : Auto 2 (*3)
03H : Manual (*4)
DATA01: The horizontal amount of movements
1 dot : 01H
to
: -
20 dot : 14H
DATA02: The vertical amount of movements
One line : 01H
to
: -
20 line : 14H
DATA03: Interval of operation 1 - 5 minutes : 01H - 05H
ACK
7FH 60H 80H 1EH 01H DATA00 CKS
DATA00: Mode
00H : OFF
01H : Auto 1
02H : Auto 2
03H : Manual
(*1)A picture shift function is a function that is made to carry out rotation
movement of the image, and mitigates printing on a screen.
(*2)At the time of PC input, after reducing an image, a picture shift is
performed. Reduction of an image does not carry out at the time of an
animation input.
(*3) At the time of PC input, after expanding an image, a picture shift is
performed. Expansion of an image does not carry out at the time of an
animation input.
(*4) It is not concerned with PC input and an animation input, and expansion
reduction of an image is not performed. It operates at intervals of the
horizontal and vertical amount of movements specified by DATA 01-03,
and operation.
64
66. OSM OBITER
Function
In order to decrease printing of a screen by OSM display, whenever it displays
OSM, shift operation of the OSM is carried out.
Transmission Data
DFH 80H 60H 5FH 01H DATA00
DATA00 01H : OBITER ON
02H : OBITER OFF
CKS
ACK
7FH 60H 80H 5FH 01H DATA00
DATA00 01H : OBITER ON
02H : OBITER OFF
CKS
67. OSM ANGLE
Function
The vertical display of OSM and a horizontal display are chosen.
Transmission Data
DFH 80H 60H 60H 01H DATA00
CKS
DATA00
01H : Horizontal display
02H : Vertical display
ACK
7FH 60H 80H 60H 01H DATA00
CKS
DATA00
01H : Horizontal display
02H : Vertical display
68. Input Skip
Function
In a monitor's key "an input change", when there is no signal, it flies and shifts
to the following channel.
Transmission Data
DFH 80H 60H 61H 01H DATA00
DATA00 01H : ON
CKS
CKS
02H : OFF
ACK
7FH 60H 80H 61H 01H DATA00
DATA00 01H : ON
02H : OFF
65
69. PICTURE Size
Function
Screen mode selection.
Transmission Data
DFH 80H 60H 2AH 01H DATA00
DATA00 01H : ON
CKS
CKS
02H : OFF
ACK
7FH 60H 80H 2AH 01H DATA00
DATA00 01H : ON
02H : OFF
*This function is only 50 or 61-inch model.
70. OPTION Select
Function
Power-on mode, a control lock, and IR remote are set up.
Transmission Data
DFH 80H 60H 63H 04H DATA00 to DATA03 CKS
DATA00 : Power ON mode
00H : LAST
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H: HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
00H : OFF
DATA01 : Control Lock
DATA02 : IR remote
DATA03 : Loop Out
01H : ON
00H : OFF
01H : ON
00H : OFF
01H : ON
ACK
7FH 60H 80H 63H 00H CKS
66
71. REPEAT Timer
Function
External control apparatus sets up the repeat timer of a plasma monitor.
Transmission Data
DFH 80H 60H 64H 07H DATA00 to DATA06 CKS
DATA00
00H :REPEAT Timer OFF
01H :REPEAT Timer ON
DATA01 PROGRAM 1
01H :DIVIDER 1
02H :DIVIDER 4
03H :DIVIDER 9
DATA02 SOURCE 01H :Video1
02H :Video2
03H :Video3
05H :HD (HD1 or DTV-or-DTV1)
06H :HD2 (DTV2 or SCART1/SCART2
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3 (SCART3)
DATA03 WORK TIME
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)
DATA04 PROGRAM 1
01H :DIVIDER 1
02H :DIVIDER 4
03H :DIVIDER 9
DATA05 SOURCE 01H :Video1
02H :Video2
03H :Video3
05H :HD (HD1 or DTV-or-DTV1)
06H :HD2 (DTV2 or SCART1/SCART2
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3 (SCART3)
DATA06 WORK TIME
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)
67
ACK
7FH 60H 80H 64H 00H CKS
72. SERIAL No. Request
Function
External control apparatus read the serial number of the set recorded by
EEPROM of a plasma display.
Transmission Data
1FH 80H 60H 15H 00H CKS
ACK
7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS
Even DATA00-DATA11 is set up as follows.
Setting value
00H-09H
96H
:
:
0 - 9
Blank
10H-29H
:
A-Z of Alphabet
73. S1/S2 SELECT
Function
External control apparatus sets up the S1/S2 detection of a plasma monitor.
Transmission Data
DFH 80H 60H 89H 01H DATA00 CKS
DATA00
01H : AUTO
02H : OFF
ACK
7FH 60H 80H 89H 01H DATA00 CKS
DATA00
01H : AUTO
02H : OFF
68
74. SOFT FOCUS
Function
External control apparatus sets up the Soft Focus of a plasma monitor.
Transmission Data
DFH 80H 60H 65H 01H DATA00 CKS
DATA00 01H : OFF
02H : 1
03H : 2
04H : 3
05H : 4
ACK
7FH 60H 80H 65H 01H DATA00 CKS
DATA00 01H : OFF
02H : 1
03H : 2
04H : 3
05H : 4
75. PLUG and PLAY(only HDCP model)
Function
External control apparatus sets up the Plug and Play of a plasma monitor.
Transmission Data
DFH 80H 60H 8EH 01H DATA00 CKS
DATA00 01H : PC
02H : STB/DVD(HDCP signal)
ACK
7FH 60H 80H 8EH 01H DATA00 CKS
DATA00 01H : PC
02H : STB/DVD(HDCP signal)
69
76. DEGITAL SIGNAL LEVEL SELECT(only HDCP model)
Function
External control apparatus sets up the digital signal level of a plasma monitor.
Transmission Data
DFH 80H 60H 8FH 01H DATA00 CKS
DATA00 01H : LOW
02H : HIGH
ACK
7FH 60H 80H 8FH 01H DATA00 CKS
DATA00 01H : LOW
02H : HIGH
77. MULTI(SPRIT) SCREEN Select
Function
External control apparatus selects a screen mode from alternatives
mentioned below, such as single mode, side-by-side, picture in picture,
etc., of Plasma Monitor.
Transmission Data
DFH 80H 60H 07H 01H DATA00 CKS
DATA00: 00H: Single Screen
01H: Side by Side 1 (Same Size Screen)
02H: Side-by-Side 2R (Left Screen smaller)
03H: Picture in Picture 1 (sub screen Bottom Left) with size1
04H: Picture in Picture2(sub screen Bottom Right) with size1
05H: Side-by-Side 2L (Left Screen Bigger)
06H: Picture in Picture 1(sub screen Bottom Left) with size2
07H: Picture in Picture 2(sub screen Bottom Right) with size2
08H: Picture in Picture 1(sub screen Bottom Left) with size3
09H: Picture in Picture 2(sub screen Bottom Right) with size3
0AH: Picture in Picture 1(sub screen Bottom Left) with size4
0BH: Picture in Picture 2(sub screen Bottom Right) with size4
41H: Picture in Picture 3(sub screen Top Right) with size1
42H: Picture in Picture 3(sub screen Top Right) with size2
43H: Picture in Picture 3(sub screen Top Right) with size3
70
44H: Picture in Picture 3(sub screen Top Right) with size4
45H: Picture in Picture 4(sub screen Top Left) with size1
46H: Picture in Picture 4(sub screen Top Left) with size2
47H: Picture in Picture 4(sub screen Top Left) with size3
48H: Picture in Picture 4(sub screen Top Left) with size4
49H: Side by Side 3 (Same Size Screen vertical expand)
4AH: Side by Side 4 R(Left Screen smaller vertical expand)
4BH: Side by Side 4 L(Left Screen Bigger vertical expand)
In case of Side by Side mode;
20H: Active Left
21H: Active Right
In case of Picture in picture mode;
30H: Active Main
31H: Active Sub
ACK
7FH 60H 80H 07H 01H DATA00 CKS
DATA00: 00H: Single Screen
01H: Side by Side 1 (Same Size Screen)
02H: Side-by-Side 2R (Left Screen smaller)
03H: Picture in Picture 1 (sub screen Bottom Left) with size1
04H: Picture in Picture2(sub screen Bottom Right) with size1
05H: Side-by-Side 2L (Left Screen Bigger)
06H: Picture in Picture 1(sub screen Bottom Left) with size2
07H: Picture in Picture 2(sub screen Bottom Right) with size2
08H: Picture in Picture 1(sub screen Bottom Left) with size3
09H: Picture in Picture 2(sub screen Bottom Right) with size3
0AH: Picture in Picture 1(sub screen Bottom Left) with size4
0BH: Picture in Picture 2(sub screen Bottom Right) with size4
41H: Picture in Picture 3(sub screen Top Right) with size1
42H: Picture in Picture 3(sub screen Top Right) with size2
43H: Picture in Picture 3(sub screen Top Right) with size3
44H: Picture in Picture 3(sub screen Top Right) with size4
45H: Picture in Picture 4(sub screen Top Left) with size1
46H: Picture in Picture 4(sub screen Top Left) with size2
47H: Picture in Picture 4(sub screen Top Left) with size3
48H: Picture in Picture 4(sub screen Top Left) with size4
49H: Side by Side 3 (Same Size Screen vertical expand)
71
4AH: Side-by-Side 4R (Left Screen smaller vertical expand)
4BH: Side-by-Side 4L (Left Screen Bigger vertical expand)
In case of Side by Side mode;
20H: Active Left
21H: Active Right
In case of Picture in picture mode;
30H: Active Main
31H: Active Sub
78. SUB PICTURE DETECT SELECT
Function
External control apparatus selects whether to display the sub picture or not,
under picture in picture mode, of plasma monitor.
Transmission Data
DFH 80H 60H 7AH 01H DATA00 CKS
DATA00 01H : OFF
02H : AUTO
ACK
7FH 60H 80H 7AH 01H DATA00 CKS
DATA00 01H : OFF
02H : AUTO
79. ZOOM NAVIGATION SELECT
Function
External control apparatus selects digital zoom display of a plasma monitor,
from the alternatives mentioned below;
Transmission Data
DFH 80H 60H 7BH 01H DATA00 CKS
DATA00
01H : NORMAL
02H : Side By Side(Left Screen smaller)
03H : Picture in Picture1(Sub Screen Bottom Left)
04H : Picture in Picture2(Sub Screen Bottom Right)
05H : Picture in Picture3(Sub Screen Top Right)
06H : Picture in Picture4(Sub Screen Top Left)
ACK
7FH 60H 80H 7BH 01H DATA00 CKS
DATA00 01H : NORMAL
72
02H : Side-By-Side
03H : Picture in Picture1(Sub Screen Bottom Left)
04H : Picture in Picture2(Sub Screen Bottom Right)
05H : Picture in Picture3(Sub Screen Top Right)
06H : Picture in Picture4(Sub Screen Top Left)
80. PICTURE FREEZE SELECT
Function
External control apparatus selects the picture freeze function of a plasma
monitor.
Transmission Data
DFH 80H 60H 7CH 01H DATA00 CKS
DATA00 01H : OFF(single screen)
02H : Side By Side1(Same Size Screen)
03H : Picture in Picture1(Sub Screen Bottom Left)
04H : Picture in Picture2(Sub Screen Bottom Right)
05H : Picture in Picture3(Sub Screen Top Right)
06H : Picture in Picture4(Sub Screen Top Left)
07H: Side by Side2 (Same Size Screen vertical expand)
ACK
7FH 60H 80H 7CH 01H DATA00 CKS
DATA00 01H : OFF(single screen)
02H : Side By Side1
03H : Picture in Picture1(Sub Screen Bottom Left)
04H : Picture in Picture2(Sub Screen Bottom Right)
05H : Picture in Picture3(Sub Screen Top Right)
06H : Picture in Picture4(Sub Screen Top Left)
07H : Side by Side2(Same Size Screen vertical expand)
81. PICTURE FREEZE Command
Function
External control apparatus sets picture freeze or remove picture freeze of a
plasma monitor.
Transmission Data
DFH 80H 60H 7DH 01H DATA00 CKS
DATA00 01H : FREEZE
02H : FREEZE OFF
73
ACK
7FH 60H 80H 7DH 01H DATA00 CKS
DATA00 01H : FREEZE
02H : FREEZE OFF
82. SEAMLESS SWITCH SELECT
Function
External control apparatus selects the seamless switch function of a plasma
monitor.
Transmission Data
DFH 80H 60H 7EH 01H DATA00 DATA01 DATA02 CKS
DATA00: SEAMLESS SWITCH
01H :OFF
02H :ON
DATA01 : SELECT1
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
01H : Video1
DATA02 : SELECT2
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
ACK
7FH 60H 80H 7EH 01H DATA00 CKS
DATA00 01H : OFF
02H : ON
74
83. MULTI (SPRIT) SCREEN PROGRAM TIMER SET
Function
External control apparatus sets multi (sprit) screen program timer of a plasma
monitor.
Transmission Data
DFH 80H 60H 32H 0AH DATA00~DATA09 CKS
DATA00 PROGRAM No
DATA01 DATE
01H~07H :No1~No7
01H~07H : Sunday~Saturday
08H : Everyday
09H~0FH:Every Sunday~Every Saturday
FFH : - (no setteing)
DATA02 ON time(hour)
00H~09H:00~09
10H~19H:10~19
20H~23H:20~23
FFH : - (no setteing)
DATA03 ON time(minute) 00H~09H : 00~09
10H~19H:10~19
20H~29H:20~29
30H~39H:30~39
40H~49H:40~49
50H~59H:50~59
FFH : - (no setteing)
DATA04 OFF time(hour) 00H~09H:00~09
10H~19H:10~19
20H~23H:20~23
FFH : - (no setting)
DATA05 OFF time(minute)00H~09H : 00~09
10H~19H:10~19
20H~29H:20~29
30H~39H:30~39
40H~49H:40~49
50H~59H:50~59
FFH : - (no setteing)
DATA06 MULTI MODE
01H : Side By Side1(Same Size Screen)
02H : Side By Side2(Left Screen Smaller)
03H : Side By Side2(Left Screen Bigger)
75
04H : Picture in Picture1(Sub Screen Bottom Left)
05H : Picture in Picture2(Sub Screen Bottom Right)
06H : Picture in Picture3(Sub Screen Top Right)
07H : Picture in Picture4(Sub Screen Top Left)
DATA07 INPUT1(Left or main)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
DATA08 INPUT2(Right or Sub)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
01H : ORBITER
DATA09 MODE
02H : INVERSE
03H : WHITE
04H : WIPER
FFH : - (no setting)
ACK
7FH 60H 80H 30H 00H CKS
76
84. MULTI (SPRIT) SCREEN POWER ON MODE SET
Function
External control apparatus sets “multi (sprit) screen power on mode” of a
plasma monitor.
Transmission Data
DFH 80H 60H 33H 04H DATA00~DATA03 CKS
DATA00 POWER ON MODE
01H:LAST
02H:MULTI
DATA01 MULTI MODE
01H : Side By Side1(Same Size Screen)
02H : Side By Side2(Left Screen Smaller)
03H : Side By Side2(Left Screen Bigger)
04H : Picture in Picture1(Sub Screen Bottom Left)
05H : Picture in Picture2(Sub Screen Bottom Right)
06H : Picture in Picture3(Sub Screen Top Right)
07H : Picture in Picture4(Sub Screen Top Left)
DATA02 INPUT1(Left or main)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
DATA03 INPUT2(Right or Sub)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
77
0DH : HD3(SCART3)
33H 00H CKS
ACK
7FH 60H
80H
85. MULTI (SPRIT) REPEAT TIMER SET
Function
External control apparatus sets “multi (sprit) screen repeat timer” of a plasma
monitor.
Transmission Data
DFH 80H 60H 34H 09H DATA00~DATA03 CKS
DATA00 REPEAT TIMER 00H:OFF
01H:ON
REPEAT1
DATA01 MULTI MODE
00H : SINGLE
01H : Side By Side1(Same Size Screen)
02H : Side By Side2(Left Screen Smaller)
03H : Side By Side2(Left Screen Bigger)
04H : Picture in Picture1(Sub Screen Bottom Left)
05H : Picture in Picture2(Sub Screen Bottom Right)
06H : Picture in Picture3(Sub Screen Top Right)
07H : Picture in Picture4(Sub Screen Top Left)
DATA02 INPUT1(Left or main)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
DATA03 INPUT2(Right or Sub)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
78
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
DATA04 WORK TIME 01H~FFH : 1~255 minutes
(1 minutes~4 hour 15 minutes)
REPEAT2
DATA05 MULTI MODE
00H : SINGLE
01H : Side By Side1(Same Size Screen)
02H : Side By Side2(Left Screen Smaller)
03H : Side By Side2(Left Screen Bigger)
04H : Picture in Picture1(Sub Screen Bottom Left)
05H : Picture in Picture2(Sub Screen Bottom Right)
06H : Picture in Picture3(Sub Screen Top Right)
07H : Picture in Picture4(Sub Screen Top Left)
DATA06 INPUT1(Left or main)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
DATA07 INPUT2(Right or Sub)
01H : Video1
02H : Video2
03H : Video3
05H : HD (HD1 or DTV or DTV1)
06H : HD2 (DTV2 or SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
79
0DH : HD3(SCART3)
DATA08 WORK TIME
01H~FFH : 1~255 minutes
(1 minutes~4 hour 15 minutes)
NOTE: When “SINGLE” is selected at DATA01 or DATA04,
”INPUT MODE 1” will be repeated.
ACK
7FH 60H
80H
34H
00H
CKS
86. OSM CONTRAST SELECT
Function
External control apparatus selects the OSM contrast function of a plasma
monitor.
Transmission Data
DFH 80H 60H 37H 01H DATA00 CKS
DATA00 01H : NORMAL
02H : LOW
ACK
7FH 60H 80H 37H 01H DATA00 CKS
DATA00 01H : NORMAL
02H : LOW
80
87. CC (Closed caption) SELECT
Function
External control apparatus selects the Closed Caption function of a plasma
monitor.
Transmission Data
DFH 80H 60H 3CH 01H DATA00 CKS
DATA00 00H : OFF
01H : CC1(closed caption1)
02H : CC2(closed caption2)
03H : CC3(closed caption3)
04H : CC4(closed caption4)
05H : TEXT1
06H : TEXT2
07H : TEXT3
08H : TEXT4
ACK
7FH 60H 80H 3CH 01H DATA00 CKS
DATA00 00H : OFF
01H : CC1(closed caption1)
02H : CC2(closed caption2)
03H : CC3(closed caption3)
04H : CC4(closed caption4)
05H : TEXT1
06H : TEXT2
07H : TEXT3
08H : TEXT4
81
88. CC (Closed caption) CONTRAST SELECT
Function
External control apparatus selects the Closed Caption Contrast function of a
plasma monitor.
Transmission Data
DFH 80H 60H 3DH 01H DATA00 CKS
DATA00 01H : NORMAL
02H : LOW
ACK
7FH 60H 80H 3DH 01H DATA00 CKS
DATA00 01H : NORMAL
02H : LOW
82
|