Powerware Power Supply P93 User Manual

Powerware P93 (9330-20) UPS  
Features  
Ideal applications  
Ī iSeries 870 and 890  
Ī pSeries 655, 670 and 690  
Ī Enterprise Storage Server Model 800  
Ī Cluster Server 1650  
P93 features  
Ī UPS is pre-architected, tested and  
optimized for eServer and storage  
applications  
Ī Pre-installation site evaluation*  
Ī Includes UPS installation and  
start-up service*  
Ī Output distribution with breakers,  
cables and receptacles  
Ī ProActive 1-year service plan  
Ī Exclusive 5-year onsite warranty  
offered through IBM with  
IBMSERV coordination  
UPS benefits  
Ī Maximum availability – with true  
double-conversion online design,  
the proven technology that is  
used for the most mission-critical  
applications in the world  
Designed specifically to meet the high-availability  
needs of critical 24x7 applications for small to  
medium-size business, the Powerware P93 delivers  
enhanced system reliability and the highest  
efficiency ratings of any online UPS in the 20 kVA  
range. The P93 also contains high-end features and  
benefits that only existed in larger capacity UPS,  
until now.  
Superior cooling design  
The superior cooling design of the Powerware P93  
draws from Powerware’s extensive, almost 40 years  
of industry and product development experience.  
This design, which features redundant fans, ensures  
that more thermally sensitive areas are cooled first.  
Ī Maximum efficiency – the  
Powerware P93’s advanced design  
features efficiency of up to 93%,  
the highest for a double-conver-  
sion online UPS in its kVA range  
Comprehensive communications and user  
interface  
Ī Maximum performance – the  
Powerware P93 delivers the high-  
est performance by using digital  
signal processing, true pulse-  
width-modulation and maximum  
IGBT responsiveness. This  
The advanced features of the Powerware P93  
include:  
A large display, mimic and control panel is  
ergonomically situated for operator interface with  
the unit. The soft keypad helps guide the operator  
through all menus and setups. A dedicated  
micro-processor had been designed and engineered  
to provide full-featured monitoring and extensive  
alarm history. It allows for additional communica-  
tion options like Internet accessibility, Ethernet,  
network links, and modems.  
Digital signal processing and pulse-width  
modulation  
True pulse-width modulation is achieved through  
the use of digital signal processing, which enables  
the IGBTs to works at their highest capacity,  
increasing system reliability and ensuring perfect  
power on the output.  
provides easy setup, drift-free  
operation and a pristine output  
*When purchased with Powerware Field  
Installation, PN 103003671, IBM PN 97P3604  
Internal battery  
Built-in control area network (CAN)  
The Powerware P93 comes with internal batteries  
that provide up to 17 minutes of backup at full  
load. The batteries are easily accessible and main-  
tained through front access slide-out trays. DC  
Expert Plus™ internal battery management system  
significantly enhances battery life.  
An integral internal and external Control Area  
Network (CAN) is incorporated into the Powerware  
P93 that assists in seamlessly integrating peripherals  
and options, controllable from the control panel.  
It also reduces the internal wiring connections  
required therefore increasing overall system reliability.  
 
DC Expert PlusBuilt-in Battery Monitoring  
Real-world business applications require a complete range of battery management and testing features, including battery runtime remaining, lifetime remaining,  
battery health, and notification, to help make critical decisions, from scheduling preventive maintenance to load shedding. Advances in firmware, digital  
technology and battery monitoring techniques enable the Powerware P93 to offer sophisticated battery management features, previously available only in  
expensive add-on systems. By ensuring optimal battery health and availability, DC Expert Plus raises the reliability of the Powerware P93 far beyond any other  
UPS in this kVA range.  
DC Expert Plus advanced features include:  
Ī
Powerware Battery Lifetime Monitor uses measures of chronological time, number of battery discharges, battery temperature, and system loading  
to determine battery lifetime remaining.  
Ī
Ī
Battery Runtime Remaining Monitor uses system loading plus internal sensing points for voltage and current data to calculate runtime remaining.  
Advanced Battery Management (ABM®) uses patented three-stage charging technique that not only increases battery service life, but also optimizes  
recharge time.  
Ī
Ī
Ī
Battery Circuit Test (BCT) performs a periodic test of the battery string to ensure that there are no open circuits that would jeopardize battery  
performance and system availability.  
Temperature Compensated Charging (TCC) monitors the battery temperature and through sophisticated algorithms adjusts the rate of charge,  
compensating for the ambient temperature to prolong the life of the battery.  
Intelligent Battery Protection (IBP) automatically adjusts the shutdown voltage of the batteries based on the length of the AC outage. This prevents  
severe battery discharge if the system is lightly loaded.  
Intelligent Communications  
The intelligent communications capability of the Powerware P93 family of UPS means improved reliability, easier network power management and expanded  
network communications. With both hardware and software communications options, Powerware provides the right communications solution for your specific  
situation.  
LanSafe  
LanSafe version 5 delivers comprehensive support including graceful, remote shutdown of UPS systems and network monitoring tools via serial, USB, and network  
connectivity options. LanSafe's exclusive SafetyNet Technology provides Network Shutdown functionality and enables network administrators to shut down the  
most critical equipment last.  
Powerware Extensions for IBM Director  
Powerware Extensions for IBM Director provide seamless integration of Powerware UPSs into the Director management system. The Extensions for IBM Director  
simplify network management tasks for critical elements of server power protection. System administrators can easily monitor, diagnose, configure, set alarms,  
schedule self-tests, check battery, gather inventory information, and control Powerware UPSs network wide from a single console within IBM Director.  
PowerVision®  
PowerVision power management software can monitor up to 64 network devices, provide data archiving and analysis to pre-  
vent power problems, and offers sophisticated notification, plus Modbus® connectivity. Through its easy-to-use graphical user  
interface, PowerVision provides critical information about the power, network-wide, in real time.  
FORESEER®  
FORESEER environmental monitoring software puts an end to worries about risks to your critical foundation equipment and  
systems. From air conditioners to water cooling systems, generators to UPS, FORESEER gives you up-to-the-minute information about any system or device  
that is fundamental to your system availability. Plus, with its unique data archiving capabilities, FORESEER can identify potential problems before they occur,  
and notify you so you can implement a solution before a crisis.  
ConnectUPS Adapters  
Powerware’s ConnectUPS-X and communications adapters provide a self-contained link between the UPS and the Ethernet  
LAN/WAN. Using HTTP, Telnet or SNMP, you can easily monitor, manage, and shut down or reboot remote UPS-protected  
servers, routers, hubs and other key network devices in a controlled manner. These adapters are also compatible with many  
third-party network management software packages.  
Connectivity - what you need by application  
Solution  
zSeries  
iSeries  
pSeries  
xSeries  
Storage  
Networking  
LanSafe software  
x
x
x
x
x
x
x
x
LanSafe software & ConnectUPS MultiServer card, IBM FC 2933  
NetWatch software & ConnectUPS Web/SNMP card, IBM FC 2934  
IBM Director Snap-in  
PowerVision software  
FORESEER Software  
x
LPARS1  
x
x
x
x
x
x
x
x
x
x
x
x
ConnectUPS relay card & AS400 cable, IBM FC 2936  
x
NOTE: One (1) X-Slot relay card and interface cable included with P93. 1. Use ConnectUPS Web/SNMP/xHub card, IBM FC 2934 to support LPAR (POWER 4 Chip Set) servers. For pSeries configurations: each LPAR  
needs a network connection and will install Powerware provided NetWatch or LanSafe V software.  
 
P93 Options  
ProActive service – additional year(s) plan description  
Ī 7x24 corrective maintenance coverage  
Ī 7x24 annual performance check  
Ī Annual power protection audit  
Ī 7x24 remote monitoring advance response  
Ī Monthly UPS performance report with web access to account information and site service activity  
Powerware  
Part Number  
155102012-001  
155102013-001  
IBM  
Feature Code  
7001  
IBM  
Part Number  
97P2657  
Per P93  
Minimum  
Maximum  
Concurrent with UPS purchase  
Non-concurrent to UPS purchase  
0
0
4
4
7002  
97P2658  
Connectivity  
ConnectUPS X-Slot Web/SNMP/xHub card (10/100Mb)  
The ConnectUPS-X Web/SNMP/xHub card provides real-time UPS monitoring and control of power throughout both 100Mb and 10Mb networks. When used  
in conjunction with NetWatch Client software, it also provides graceful shutdown of the operating system of up to 255 computers powered by a single UPS.  
The advanced features of the ConnectUPS-X include:  
Ī Real-time, enterprise-wide monitoring provides valuable information for analysis of critical power conditions and problem identification  
Ī Supports 100Mb and 10Mb Ethernet networks  
Ī Built-in three ports switching hub adds three 10/100Mb network connections with no additional expense  
Ī Monitoring via Web using computer (through standard Web Browsers, e.g. Internet Explorer and Netscape). PDA or cell phone provides easy, anywhere,  
anytime access  
Ī Monitoring via SNMP using Network Management Software packages (e.g. Tivoli, CA Unicenter and HP Openview)  
Ī Analysis of chronic power problems and determination of trends through data logging and sophisticated graphic tools  
ConnectUPS MultiServer Card  
The ConnectUPS MultiServer card is an X-Slot connectivity device that provides serial connection to up to five computers for unattended, graceful shutdown  
and power monitoring. The card operates in conjunction with LanSafe software (included with UPS). The advanced features of the MultiServer card include:  
Ī Real-time monitoring of critical power parameters  
Ī Graceful, unattended shutdown of multiple computers  
Ī Maximizes uptime of more critical loads through operation in tandem with load segment feature of UPS  
Ī Supports simple signaling (relay contacts) through additional DB-9 port  
Relay Interface Card  
The Powerware Relay Interface card is an X-Slot connectivity device that provides monitoring of UPS status through isolated, dry contact, Form-C relays.  
It also provides the interface for AS/400 computers as well as many industrial applications. The advanced features of the Relay Interface card include:  
Ī Isolated, dry contact, Form-C relays for “utility failure”, “low battery”, “UPS alarm /OK” or “on bypass”  
Ī User-selectable “normally open” or “normally closed” contacts  
Ī Remote shutdown of UPS through integrated shutdown function  
Ī Hot-swappable – UPS maintains power to critical applications while changing cards  
Powerware  
Part Number  
103002974-5501  
05146447-3901  
103003564  
IBM  
Feature Code  
2934  
IBM  
Part Number  
53P4619  
04N7027  
97P3886  
Per P93  
Minimum  
Maximum  
ConnectUPS X-Slot Web/SNMP card  
ConnectUPS X-Slot MultiServer card  
ConnectUPS Relay Interface card & cable  
0
0
0
2*  
2*  
2*  
2933  
2936  
*Maximum combination of FC 2933, 2934, 2936 and other ConnectUPS X-Slot card options is two. ConnectUPS cards are installed onsite and concurrently with P93 startup by  
Powerware Service Technician. Customer responsible for software installation.  
Output connections  
Three (3) NEMA non or locking receptacles (outlets) with breakers and connectors. Each connector shall be on a cord with maximum length of 50 feet.  
Choose from:  
pSeries  
pSeries  
zSeries  
Feature Code  
5-15R duplex  
5-20R duplex  
L5-15R  
IBM Plug Type  
iSeries Feature Code  
1412, 1413, 2960 + 9082  
Part Number  
86G7648  
Feature Code  
Part Number  
31L7061, 2, 4  
4
-
7
9800  
-
-
-
-
-
-
2960 + 9083, + 9082  
31L7067, 8  
L5-20R  
-
-
-
-
-
L5-30R  
6-15R  
L6-15R  
6-20R  
L6-20R  
L6-30R  
-
5
10  
29  
11  
12  
-
1410, 1403, 1411, 1451, 1452, 1457, 2961 & 9082  
1414, 1416, 1453, 1454, 1458  
1400, 1401, 1423  
-
-
-
-
183576, 4, 3  
186G7878, 9  
9909, 9833  
-
-
-
-
31L7070, 1  
-
-
-
-
-
1404, 1406, 1428  
1424, 1426  
11F0113, 4  
Powerware  
Part Number  
103003673  
IBM  
Feature Code  
9881  
IBM  
Part Number  
97P2660  
Per P93  
Minimum  
Maximum  
Output power cords (NEMA)  
0
6*  
*Hardware installed onsite and concurrent to P93 installation.  
 
Extended Battery Cabinets  
Powerware offers a full line of battery cabinets for the Powerware P93.  
Ī
Battery cabinets may be daisy-chained together for extended battery runtimes,  
(up to 2).  
Ī
Ī
Ī
Ī
Slide trays and modular battery packaging makes periodic servicing easy.  
Cabinets are UL 1778 listed.  
Ī
Ī
Integral configuration, which line up and match, is standard.1  
Flame retardant batteries meet UL 94V2 for computer room installations.  
Wiring installation.2  
Front-access-only enhances servicing and installation.  
Manufacturer-supplied wiring with quick disconnects provides  
plug-and-play capability for line-up and match configurations.  
A DC rated circuit breaker in each battery cabinet allows  
multiple battery strings to be serviced independently of each  
other, assuring back up power is always available to the UPS  
Quick disconnects between battery tray assemblies reduce  
battery maintenance time.  
Removable battery slide-out tray assembles provide “front  
access only” and reduce battery maintenance time.  
1. Battery cabinets can be configured as line up and match or  
remotely located. Customer must provide wiring for remotely  
located cabinets. 2. If concurrent to P93 Field Installation,  
Powerware PN 103003671, IBM PN 97P3604.  
Battery runtimes (in minutes)  
iSeries  
890  
pSeries  
670  
Storage  
2105  
Cluster  
870  
655  
690  
1350 1600  
with  
expansion  
8 way 32 way standard enclosure  
3 I/O 32 way 1 I/O 3 I/O  
7 kW 10.5 kW 14 kW 6.8 kW 4.9 kW 8.3 kW 3.2 kW 6.4 kW 9.6 kW 6.5 kW 3.2 kW 10.5 kW 6.4 kW 13.8 kW  
CEC + CEC + CEC +  
I/O I/O I/O  
10 kVA 15 kVA 20 kVA 16 way 16 way 32 way 1 I/O 2 I/O  
1
2
3
node nodes nodes up to  
Contact  
Powerware  
Internal battery  
(1) External  
battery cabinet  
(2) External  
45  
90  
26  
65  
90  
17  
48  
75  
48  
98  
79  
31  
75  
110  
240  
400  
50  
27  
70  
96  
49  
110  
240  
400  
26  
65  
90  
50  
17  
48  
75  
150  
240  
110  
180  
108  
172  
110  
180  
battery cabinets 155  
166  
130  
Contact Powerware for runtime, application or configuration assistance.  
Calculating runtime - a guide  
Typical runtime is 15 minutes  
Formula (runtime in minutes) = [business + (2 x system shutdown) + safety]  
Business = _____  
Shutdown ____ x 2 = _____  
Safety = _____  
Total = _____  
Powerware  
Part Number  
A13031  
IBM  
Feature Code  
6635  
IBM  
Part Number  
97P2663  
Per P93  
Minimum  
Maximum  
External Battery Cabinet  
0
2
Additional options  
Ī
Ī
Ī
Ī
Input/output galvanic isolation  
Voltage matching transformers  
Remote status panel  
Remote EPO button  
 
Powerware P93 Specifications  
Options  
Cabinet  
ProActive  
Service  
X-Slot  
X-Slot  
X-Slot  
Relay  
P93  
EBC  
Web/SNMP Multi Server  
Output power cords  
9880 9881  
IBM feature code  
IBM part number  
Input Voltage  
Output voltage  
Input/output frequency  
Input voltage range  
Minimum  
Maximum  
Rectifier input  
Bypass input  
Nominal amps  
AC output  
Nominal  
10 minutes  
Battery  
6635  
7001  
7002  
2934  
2933  
2936  
97P2653 97P2654  
97P2663  
97P2657 97P2658  
53P4619  
04N7027  
97P3886  
97P2659 97P2660  
Volts  
Volts  
Hz  
208  
208  
50/60  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Volts  
Volts  
Amps  
177  
228  
52  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Quantity  
(2) 60 A,  
3-phase,  
Amps  
55.5  
-
-
-
-
-
-
-
4-wire,  
IEC-309,  
460R9W  
with  
Quantity  
(3). See  
FC 9881  
Amps  
Amps  
55.5  
69.4  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
description.  
breakers  
and  
connec-  
tors.  
Nominal voltage  
Max. charge  
voltage @ 25°C  
Charge current  
Nominal discharge current Amps  
Total cell count  
Volts  
288  
-
288  
-
-
-
-
-
Volts  
Amps  
340  
7
52  
-
-
-
-
340  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
144  
144  
System efficiency  
@100% load  
@75% load  
@50% load  
%
%
%
92.4  
92.7  
92.9  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Maximum heat dissipation  
BTU/hr. (x1000)  
kcal/hr.  
3.9  
990  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Inverter efficiency  
(full load)  
%
94  
-
-
-
-
-
-
-
Physical attributes (max.)  
Width  
Height  
Depth  
Weight installed  
in/cm  
in/cm 45/114  
in/cm 31/79  
22/56  
17/52  
45/114  
38/97  
200/90  
4 @  
17/52  
45/114  
31/79  
600/272  
6 @  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
50 ft. (maximum cord)  
20 lb. each connector  
lb/kg 958/435  
.5/.2  
.5  
.5/.2  
6 @  
Point loading  
Min/max qty per P93  
lb/kg 160/73  
-
50/230  
1/1  
145/100  
0/2  
N/A  
0/4  
N/A  
0/4  
N/A  
0/2  
N/A  
0/2  
N/A  
0/2  
-
-
1/1  
0/6  
Powerware  
WORLDWIDE HEADQUARTERS  
8609 Six Forks Road  
Raleigh, NC 27615 U.S.A.  
Toll Free: 1.800.925.4426  
EUROPE/MIDDLE EAST/AFRICA  
Denmark: 45.3677.7910  
Finland: 358.9.452.661  
France: 33.1.60.12.74.00  
Germany: 49.7841.6660  
Italy: 39.02.66.04.05.40  
ASIA PACIFIC  
Australia/NZ: 612.9878.5000  
China: 86.21.6350.0606  
HK/Korea/Taiwan: 852.2745.6682  
India: 91.11.2649.9414 to 18  
Singapore/SEA: 65.6829.8888  
LATIN AMERICA  
Argentina: 5411.4343.6323  
Brazil: 55.11.3616.8500  
México: 5255.9171.7777  
CANADA  
Ontario: 416.798.0112  
Norway: 47.23.03.65.50  
Sweden: 46.8.598.940.00  
United Kingdom: 44.1753.608.700  
Revised 01/04  
Reprint 01/04  
 

Pentair Swimming Pool Pump VS+SVRS User Manual
Philips All in One Printer SFF 6135D User Manual
Philips Card Game AJ3915CD User Manual
Philips CD Player SA018102 User Manual
Philips Iron GC3360 User Manual
Philips Universal Remote VR 675 User Manual
Philips Work Light P 5909 User Manual
Planet Technology Telephone IPX 600 User Manual
Powermate Power Supply P320100 User Manual
Pride Mobility Mobility Aid 14 User Manual