By adamm15of at 8:51 am, 3/30/10
Installation and Assembly:
In-wall Mount for up to 40" Flat Panel Screens
Models: IM740P, IM740P-S
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
R
Maximum UL Load Capacity:
80 lb (36.3 kg)
ISSUED: 12-04-07 SHEET #: 095-9280-3 03-25-10
For customer care call 1-800-865-2112 or 708-865-8870.
1 of 6
Before you begin, make sure all parts shown are included with your product.
Parts may appear slightly different than illustrated.
Parts List
IM740P
Qty. Part #
IM740P-S
Part #
Description
A
B
C
D
E
F
in-wall box
1
2
2
4
2
4
2
4
095-P1536
095-C4536
#10 x 1.5" wood screw
mounting cover plate
ribbed rivet
500-2002
095-P1533
590-1296
590-1295
590-1166
590-1123
590-1168
500-2002
095-C4533
590-1296
590-1295
590-1166
590-1123
590-1168
cable bushing
cable management clips
plastic finishing cap
cable tie
G
H
Articulating Arm for
22" - 40" screens
AA
1
PA740
PA740-S
A
H
F
G
E
D
B
C
AA
PA740, PA740P-S
ArTICULATINg ArM
(SEE INSTrUCTION fOr CONTENTS
INCLUDED WITh PA740 Or PA740-S)
ISSUED: 12-04-07 SHEET #: 095-9280-3 03-25-10
For customer care call 1-800-865-2112 or 708-865-8870.
3 of 6
Installation to Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
• hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations.
In-wall box (A) must be installed between two studs 16" on
center. Use an edge-to-edge stud finder to locate the edges
1
STUD
of the stud. Based on its edges, draw two vertical lines down
the inside edges of stud’s. Mark desired center of in-wall box.
Draw a horizontal line 6-1/8" (150 mm) above center of in-wall
box (A). Draw a second horizontal line 12-1/4" (311 mm) below
this line to outline wall opening between inside edges of studs.
Remove drywall inside cut outline.
14.5"
(368mm)
CUT
OUTLINE
6-1/8"
NOTE: In-wall box (A) can be installed for left or right side
mount orientation as shown in figure 1.2.
(150mm)
12-1/4"
(311mm)
Insert in-wall box (A) into cut-out until flange is flush with
drywall.
CENTEr Of
IN-WALL BOX
Level in-wall box (A), and mark the position of two mounting
holes using holes on mounting tabs. Remove in-wall box (A)
and drill 1/8" (3 mm) dia. holes 1-1/2" (38 mm) deep using
the locations previously marked. Reinstall and level in-wall
box (A). Secure using two #10 X 1-1/2" wood screws (B) as
shown in figure 1.3.
fig. 1.1
Attach two mounting cover plates (C) to in-wall box (A) using
four ribbed rivets (D) as shown in figure 1.4.
A
A
A
MOUNTINg
TABS
fLANgE
fLANgE
RIGHT
ORIENTATION
LEFT
ORIENTATION
C
D
B
fig. 1.2
fig. 1.3
fig. 1.4
ISSUED: 12-04-07 SHEET #: 095-9280-3 03-25-10
For customer care call 1-800-865-2112 or 708-865-8870.
4 of 6
Installing Articulating Arm to In-wall Box
Choose hole pattern on interior mounting plate of in-wall box (A) which align with hole pattern on the wall plate of
PA740 articulating arm (AA). Mounting hole alignments may be selected for different height installations.
2
Note: Consider position of screen center or routing of cables before securing arm to in-wall box.
Drill two 5/32" (4 mm) holes 2.5" (65 mm) deep using interior mounting plate holes of in-wall box (A) as a guide.
Attach PA740 articulating arm (AA) to in-wall box using two #14 x 2-1/2" wood screws (included with PA740).
WALL PLATE (AA)
INTErIOr MOUNTINg PLATE (AA)
#14 X 2-1/2"
WOOD SCrEWS
(INCLUDED WITh PA740)
Installing Screen to Arm
Refer to instruction included with PA740 for screen installation to articulating arm.
3
ISSUED: 12-04-07 SHEET #: 095-9280-3 03-25-10
5 of 6
For customer care call 1-800-865-2112 or 708-865-8870.
Cable Management
For optional installation of electrical gang box, access plates located on the bottom or top of in-wall box can be
temporarily removed to install electrical gang box as shown in figure 4.1.
4
ACCESS
PLATE
fig. 4.1
SCrEEN NOT ShOWN fOr CLArITy
Insert up to four cable management clips (F) into the desired positions in the in-wall box as shown in figure 4.2
for routing cables. Refer to instruction included with PA740 articulating arm (AA) for cable management with arm.
4-1
Insert cable bushing (E) into top or bottom hole of in-wall box for routing cables through in-wall box. Plastic
finishing caps (G) can be used in holes where cables are not being routed.
NOTE: Make sure cables have enough slack to allow full movement of the arm.
Use cable ties (H) to secure cables to cable management clips as shown in figure 4.3.
fig. 4.2
fig. 4.3
CABLES
F
H
E or G
SCrEEN NOT ShOWN fOr CLArITy
ISSUED: 12-04-07 SHEET #: 095-9280-3 03-25-10
6 of 6
For customer care call 1-800-865-2112 or 708-865-8870.
© 2007, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.
|